Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 20:14
Tabular Output Report in Format: HTML
Building: HotelSmall
Environment: RUNPERIOD 1 ** Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745
Simulation Timestamp: 2020-06-03 20:15:15
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 20:15:15
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 2269.78 | 565.53 | 609.32 |
Net Site Energy | 2269.78 | 565.53 | 609.32 |
Total Source Energy | 5297.19 | 1319.82 | 1422.03 |
Net Source Energy | 5297.19 | 1319.82 | 1422.03 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4013.58 |
Net Conditioned Building Area | 3725.09 |
Unconditioned Building Area | 288.49 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 5.70 | 2.39 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 400.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 557.66 | 421.49 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 167.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 484.05 | 0.00 | 0.00 | 0.00 | 2578.17 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1361.85 | 907.93 | 0.00 | 0.00 | 0.00 | 2578.17 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 5.70 | 2.39 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 400.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 185.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 44.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 279.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 248.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 0.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Laundry | 28.48 | 421.49 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 167.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 484.05 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2578.17 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 61.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 154.14 | 130.58 | 0.00 | 0.00 | 0.00 | 0.69 |
Other | 149.70 | 113.15 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 365.59 | 243.73 | 0.00 | 0.00 | 0.00 | 0.69 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 57.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 143.06 | 121.20 | 0.00 | 0.00 | 0.00 | 0.64 |
Other | 138.94 | 105.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 339.31 | 226.21 | 0.00 | 0.00 | 0.00 | 0.64 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1361.854 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1361.854 | 100.00 |
Total On-Site and Utility Electric Sources | 1361.854 | 100.00 |
Total Electricity End Uses | 1361.854 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 2578.17 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 2578.17 | 100.00 |
Total Water End Uses | 2578.17 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 686.50 |
Time Setpoint Not Met During Occupied Cooling | 7502.83 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 7904.33 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME HOTELSMALL
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 2B
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_AZ_TUCSON
| Meter |ZoneCoolingSummaryMonthly
| REARSTAIRSFLR1 | CORRIDORFLR1 | REARSTORAGEFLR1 | FRONTLOUNGEFLR1 | RESTROOMFLR1 | MEETINGROOMFLR1 | MECHANICALROOMFLR1 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | EMPLOYEELOUNGEFLR1 | LAUNDRYROOMFLR1 | ELEVATORCOREFLR1 | EXERCISECENTERFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | FRONTSTORAGEFLR1 | REARSTAIRSFLR2 | CORRIDORFLR2 | REARSTORAGEFLR2 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | ELEVATORCOREFLR2 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | FRONTSTORAGEFLR2 | FRONTSTAIRSFLR2 | REARSTAIRSFLR3 | CORRIDORFLR3 | REARSTORAGEFLR3 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | ELEVATORCOREFLR3 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | FRONTSTORAGEFLR3 | FRONTSTAIRSFLR3 | REARSTAIRSFLR4 | CORRIDORFLR4 | REARSTORAGEFLR4 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | ELEVATORCOREFLR4 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | FRONTSTORAGEFLR4 | FRONTSTAIRSFLR4 |ZoneHeatingSummaryMonthly
| REARSTAIRSFLR1 | CORRIDORFLR1 | REARSTORAGEFLR1 | FRONTLOUNGEFLR1 | RESTROOMFLR1 | MEETINGROOMFLR1 | MECHANICALROOMFLR1 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | EMPLOYEELOUNGEFLR1 | LAUNDRYROOMFLR1 | ELEVATORCOREFLR1 | EXERCISECENTERFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | FRONTSTORAGEFLR1 | REARSTAIRSFLR2 | CORRIDORFLR2 | REARSTORAGEFLR2 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | ELEVATORCOREFLR2 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | FRONTSTORAGEFLR2 | FRONTSTAIRSFLR2 | REARSTAIRSFLR3 | CORRIDORFLR3 | REARSTORAGEFLR3 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | ELEVATORCOREFLR3 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | FRONTSTORAGEFLR3 | FRONTSTAIRSFLR3 | REARSTAIRSFLR4 | CORRIDORFLR4 | REARSTORAGEFLR4 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | ELEVATORCOREFLR4 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | FRONTSTORAGEFLR4 | FRONTSTAIRSFLR4 |ZoneElectricSummaryMonthly
| CORRIDORFLR1 | CORRIDORFLR2 | CORRIDORFLR3 | CORRIDORFLR4 | ELEVATORCOREFLR1 | ELEVATORCOREFLR2 | ELEVATORCOREFLR3 | ELEVATORCOREFLR4 | EMPLOYEELOUNGEFLR1 | EXERCISECENTERFLR1 | FRONTLOUNGEFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | FRONTSTAIRSFLR2 | FRONTSTAIRSFLR3 | FRONTSTAIRSFLR4 | FRONTSTORAGEFLR1 | FRONTSTORAGEFLR2 | FRONTSTORAGEFLR3 | FRONTSTORAGEFLR4 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | LAUNDRYROOMFLR1 | MECHANICALROOMFLR1 | MEETINGROOMFLR1 | REARSTAIRSFLR1 | REARSTAIRSFLR2 | REARSTAIRSFLR3 | REARSTAIRSFLR4 | REARSTORAGEFLR1 | REARSTORAGEFLR2 | REARSTORAGEFLR3 | REARSTORAGEFLR4 | RESTROOMFLR1 |SpaceGainsMonthly
| CORRIDORFLR1 | CORRIDORFLR2 | CORRIDORFLR3 | CORRIDORFLR4 | ELEVATORCOREFLR1 | ELEVATORCOREFLR2 | ELEVATORCOREFLR3 | ELEVATORCOREFLR4 | EMPLOYEELOUNGEFLR1 | EXERCISECENTERFLR1 | FRONTLOUNGEFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | FRONTSTAIRSFLR2 | FRONTSTAIRSFLR3 | FRONTSTAIRSFLR4 | FRONTSTORAGEFLR1 | FRONTSTORAGEFLR2 | FRONTSTORAGEFLR3 | FRONTSTORAGEFLR4 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | LAUNDRYROOMFLR1 | MECHANICALROOMFLR1 | MEETINGROOMFLR1 | REARSTAIRSFLR1 | REARSTAIRSFLR2 | REARSTAIRSFLR3 | REARSTAIRSFLR4 | REARSTORAGEFLR1 | REARSTORAGEFLR2 | REARSTORAGEFLR3 | REARSTORAGEFLR4 | RESTROOMFLR1 |PeakSpaceGainsMonthly
| CORRIDORFLR1 | CORRIDORFLR2 | CORRIDORFLR3 | CORRIDORFLR4 | ELEVATORCOREFLR1 | ELEVATORCOREFLR2 | ELEVATORCOREFLR3 | ELEVATORCOREFLR4 | EMPLOYEELOUNGEFLR1 | EXERCISECENTERFLR1 | FRONTLOUNGEFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | FRONTSTAIRSFLR2 | FRONTSTAIRSFLR3 | FRONTSTAIRSFLR4 | FRONTSTORAGEFLR1 | FRONTSTORAGEFLR2 | FRONTSTORAGEFLR3 | FRONTSTORAGEFLR4 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | LAUNDRYROOMFLR1 | MECHANICALROOMFLR1 | MEETINGROOMFLR1 | REARSTAIRSFLR1 | REARSTAIRSFLR2 | REARSTAIRSFLR3 | REARSTAIRSFLR4 | REARSTORAGEFLR1 | REARSTORAGEFLR2 | REARSTORAGEFLR3 | REARSTORAGEFLR4 | RESTROOMFLR1 |SpaceGainComponentsAtCoolingPeakMonthly
| REARSTAIRSFLR1 | CORRIDORFLR1 | REARSTORAGEFLR1 | FRONTLOUNGEFLR1 | RESTROOMFLR1 | MEETINGROOMFLR1 | MECHANICALROOMFLR1 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | EMPLOYEELOUNGEFLR1 | LAUNDRYROOMFLR1 | ELEVATORCOREFLR1 | EXERCISECENTERFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | FRONTSTORAGEFLR1 | REARSTAIRSFLR2 | CORRIDORFLR2 | REARSTORAGEFLR2 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | ELEVATORCOREFLR2 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | FRONTSTORAGEFLR2 | FRONTSTAIRSFLR2 | REARSTAIRSFLR3 | CORRIDORFLR3 | REARSTORAGEFLR3 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | ELEVATORCOREFLR3 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | FRONTSTORAGEFLR3 | FRONTSTAIRSFLR3 | REARSTAIRSFLR4 | CORRIDORFLR4 | REARSTORAGEFLR4 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | ELEVATORCOREFLR4 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | FRONTSTORAGEFLR4 | FRONTSTAIRSFLR4 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| REARSTAIRSFLR1 | CORRIDORFLR1 | REARSTORAGEFLR1 | FRONTLOUNGEFLR1 | RESTROOMFLR1 | MEETINGROOMFLR1 | MECHANICALROOMFLR1 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | EMPLOYEELOUNGEFLR1 | LAUNDRYROOMFLR1 | ELEVATORCOREFLR1 | EXERCISECENTERFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | FRONTSTORAGEFLR1 | REARSTAIRSFLR2 | CORRIDORFLR2 | REARSTORAGEFLR2 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | ELEVATORCOREFLR2 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | FRONTSTORAGEFLR2 | FRONTSTAIRSFLR2 | REARSTAIRSFLR3 | CORRIDORFLR3 | REARSTORAGEFLR3 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | ELEVATORCOREFLR3 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | FRONTSTORAGEFLR3 | FRONTSTAIRSFLR3 | REARSTAIRSFLR4 | CORRIDORFLR4 | REARSTORAGEFLR4 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | ELEVATORCOREFLR4 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | FRONTSTORAGEFLR4 | FRONTSTAIRSFLR4 |ComfortReportSimple55Monthly
| REARSTAIRSFLR1 | CORRIDORFLR1 | REARSTORAGEFLR1 | FRONTLOUNGEFLR1 | RESTROOMFLR1 | MEETINGROOMFLR1 | MECHANICALROOMFLR1 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | EMPLOYEELOUNGEFLR1 | LAUNDRYROOMFLR1 | ELEVATORCOREFLR1 | EXERCISECENTERFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | FRONTSTORAGEFLR1 | REARSTAIRSFLR2 | CORRIDORFLR2 | REARSTORAGEFLR2 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | ELEVATORCOREFLR2 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | FRONTSTORAGEFLR2 | FRONTSTAIRSFLR2 | REARSTAIRSFLR3 | CORRIDORFLR3 | REARSTORAGEFLR3 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | ELEVATORCOREFLR3 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | FRONTSTORAGEFLR3 | FRONTSTAIRSFLR3 | REARSTAIRSFLR4 | CORRIDORFLR4 | REARSTORAGEFLR4 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | ELEVATORCOREFLR4 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | FRONTSTORAGEFLR4 | FRONTSTAIRSFLR4 |OccupantComfortDataSummaryMonthly
| CORRIDORFLR1_PEOPLE | CORRIDORFLR2_PEOPLE | CORRIDORFLR3_PEOPLE | CORRIDORFLR4_PEOPLE | ELEVATORCOREFLR1_PEOPLE | ELEVATORCOREFLR2_PEOPLE | ELEVATORCOREFLR3_PEOPLE | ELEVATORCOREFLR4_PEOPLE | EMPLOYEELOUNGEFLR1_PEOPLE | EXERCISECENTERFLR1_PEOPLE | FRONTLOUNGEFLR1_PEOPLE | FRONTOFFICEFLR1_PEOPLE | FRONTSTAIRSFLR1_PEOPLE | FRONTSTAIRSFLR2_PEOPLE | FRONTSTAIRSFLR3_PEOPLE | FRONTSTAIRSFLR4_PEOPLE | FRONTSTORAGEFLR1_PEOPLE | FRONTSTORAGEFLR2_PEOPLE | FRONTSTORAGEFLR3_PEOPLE | FRONTSTORAGEFLR4_PEOPLE | GUESTROOM101_PEOPLE | GUESTROOM102_PEOPLE | GUESTROOM103_PEOPLE | GUESTROOM104_PEOPLE | GUESTROOM105_PEOPLE | GUESTROOM201_PEOPLE | GUESTROOM202_205_PEOPLE | GUESTROOM206_208_PEOPLE | GUESTROOM209_212_PEOPLE | GUESTROOM213_PEOPLE | GUESTROOM214_PEOPLE | GUESTROOM215_218_PEOPLE | GUESTROOM219_PEOPLE | GUESTROOM220_223_PEOPLE | GUESTROOM224_PEOPLE | GUESTROOM301_PEOPLE | GUESTROOM302_305_PEOPLE | GUESTROOM306_308_PEOPLE | GUESTROOM309_312_PEOPLE | GUESTROOM313_PEOPLE | GUESTROOM314_PEOPLE | GUESTROOM315_318_PEOPLE | GUESTROOM319_PEOPLE | GUESTROOM320_323_PEOPLE | GUESTROOM324_PEOPLE | GUESTROOM401_PEOPLE | GUESTROOM402_405_PEOPLE | GUESTROOM406_408_PEOPLE | GUESTROOM409_412_PEOPLE | GUESTROOM413_PEOPLE | GUESTROOM414_PEOPLE | GUESTROOM415_418_PEOPLE | GUESTROOM419_PEOPLE | GUESTROOM420_423_PEOPLE | GUESTROOM424_PEOPLE | LAUNDRYROOMFLR1_PEOPLE | MECHANICALROOMFLR1_PEOPLE | MEETINGROOMFLR1_PEOPLE | REARSTAIRSFLR1_PEOPLE | REARSTAIRSFLR2_PEOPLE | REARSTAIRSFLR3_PEOPLE | REARSTAIRSFLR4_PEOPLE | REARSTORAGEFLR1_PEOPLE | REARSTORAGEFLR2_PEOPLE | REARSTORAGEFLR3_PEOPLE | REARSTORAGEFLR4_PEOPLE | RESTROOMFLR1_PEOPLE |DXReportMonthly
| 101 PTAC COOLING COIL | 102 PTAC COOLING COIL | 103 PTAC COOLING COIL | 104 PTAC COOLING COIL | 105 PTAC COOLING COIL | 201 PTAC COOLING COIL | 202_205 PTAC COOLING COIL | 206_208 PTAC COOLING COIL | 209_212 PTAC COOLING COIL | 213 PTAC COOLING COIL | 214 PTAC COOLING COIL | 215_218 PTAC COOLING COIL | 219 PTAC COOLING COIL | 220_223 PTAC COOLING COIL | 224 PTAC COOLING COIL | 301 PTAC COOLING COIL | 302_305 PTAC COOLING COIL | 306_308 PTAC COOLING COIL | 309_312 PTAC COOLING COIL | 313 PTAC COOLING COIL | 314 PTAC COOLING COIL | 315_318 PTAC COOLING COIL | 319 PTAC COOLING COIL | 320_323 PTAC COOLING COIL | 324 PTAC COOLING COIL | 401 PTAC COOLING COIL | 402_405 PTAC COOLING COIL | 406_408 PTAC COOLING COIL | 409_412 PTAC COOLING COIL | 413 PTAC COOLING COIL | 414 PTAC COOLING COIL | 415_418 PTAC COOLING COIL | 419 PTAC COOLING COIL | 420_423 PTAC COOLING COIL | 424 PTAC COOLING COIL | CORRIDORFLR1 PTAC COOLING COIL | CORRIDORFLR2 PTAC COOLING COIL | CORRIDORFLR3 PTAC COOLING COIL | CORRIDORFLR4 PTAC COOLING COIL | SAC_FRONTOFFICE COOLING COIL | SAC_FRONTLOUNGE COOLING COIL | SAC_MEETINGROOM COOLING COIL | SAC_EXC_EMPLGE_RESTRM COOLING COIL |WindowReportMonthly
| W_CORRIDORFLR1_2_0_0_0_0 | D_CORRIDORFLR1_16_0_0_0_0 | W_CORRIDORFLR1_20_0_0_0_0 | W_FRONTLOUNGEFLR1_5_0_0_0_0 | W_FRONTLOUNGEFLR1_5_0_0_0_1 | W_FRONTLOUNGEFLR1_5_0_0_0_2 | W_FRONTLOUNGEFLR1_5_0_0_0_3 | W_FRONTLOUNGEFLR1_5_0_0_0_4 | W_MEETINGROOMFLR1_5_0_0_0_0 | W_MEETINGROOMFLR1_5_0_0_0_1 | W_MEETINGROOMFLR1_5_0_0_0_2 | W_GUESTROOM101_5_0_0_0_0 | W_GUESTROOM102_5_0_0_0_0 | W_GUESTROOM103_5_0_0_0_0 | W_GUESTROOM104_3_0_0_0_0 | W_GUESTROOM105_3_0_0_0_0 | W_EMPLOYEELOUNGEFLR1_3_0_0_0_0 | W_LAUNDRYROOMFLR1_3_0_0_0_0 | W_LAUNDRYROOMFLR1_3_0_0_0_1 | W_LAUNDRYROOMFLR1_3_0_0_0_2 | W_EXERCISECENTERFLR1_3_0_0_0_0 | W_FRONTOFFICEFLR1_3_0_0_0_0 | W_FRONTOFFICEFLR1_3_0_0_0_1 | W_FRONTOFFICEFLR1_3_0_0_0_2 | W_FRONTOFFICEFLR1_3_0_0_0_3 | W_CORRIDORFLR2_2_0_0_0_0 | W_CORRIDORFLR2_15_0_0_0_0 | W_GUESTROOM201_5_0_0_0_0 | W_GUESTROOM202_205_5_0_0_0_0 | W_GUESTROOM202_205_5_0_0_0_1 | W_GUESTROOM202_205_5_0_0_0_2 | W_GUESTROOM202_205_5_0_0_0_3 | W_GUESTROOM206_208_5_0_0_0_0 | W_GUESTROOM206_208_5_0_0_0_1 | W_GUESTROOM206_208_5_0_0_0_2 | W_GUESTROOM209_212_5_0_0_0_0 | W_GUESTROOM209_212_5_0_0_0_1 | W_GUESTROOM209_212_5_0_0_0_2 | W_GUESTROOM209_212_5_0_0_0_3 | W_GUESTROOM213_5_0_0_0_0 | W_GUESTROOM214_3_0_0_0_0 | W_GUESTROOM215_218_3_0_0_0_0 | W_GUESTROOM215_218_3_0_0_0_1 | W_GUESTROOM215_218_3_0_0_0_2 | W_GUESTROOM215_218_3_0_0_0_3 | W_GUESTROOM219_3_0_0_0_0 | W_GUESTROOM220_223_3_0_0_0_0 | W_GUESTROOM220_223_3_0_0_0_1 | W_GUESTROOM220_223_3_0_0_0_2 | W_GUESTROOM220_223_3_0_0_0_3 | W_GUESTROOM224_3_0_0_0_0 | W_CORRIDORFLR3_2_0_0_0_0 | W_CORRIDORFLR3_15_0_0_0_0 | W_GUESTROOM301_5_0_0_0_0 | W_GUESTROOM302_305_5_0_0_0_0 | W_GUESTROOM302_305_5_0_0_0_1 | W_GUESTROOM302_305_5_0_0_0_2 | W_GUESTROOM302_305_5_0_0_0_3 | W_GUESTROOM306_308_5_0_0_0_0 | W_GUESTROOM306_308_5_0_0_0_1 | W_GUESTROOM306_308_5_0_0_0_2 | W_GUESTROOM309_312_5_0_0_0_0 | W_GUESTROOM309_312_5_0_0_0_1 | W_GUESTROOM309_312_5_0_0_0_2 | W_GUESTROOM309_312_5_0_0_0_3 | W_GUESTROOM313_5_0_0_0_0 | W_GUESTROOM314_3_0_0_0_0 | W_GUESTROOM315_318_3_0_0_0_0 | W_GUESTROOM315_318_3_0_0_0_1 | W_GUESTROOM315_318_3_0_0_0_2 | W_GUESTROOM315_318_3_0_0_0_3 | W_GUESTROOM319_3_0_0_0_0 | W_GUESTROOM320_323_3_0_0_0_0 | W_GUESTROOM320_323_3_0_0_0_1 | W_GUESTROOM320_323_3_0_0_0_2 | W_GUESTROOM320_323_3_0_0_0_3 | W_GUESTROOM324_3_0_0_0_0 | W_CORRIDORFLR4_2_0_0_0_0 | W_CORRIDORFLR4_15_0_0_0_0 | W_GUESTROOM401_5_0_0_0_0 | W_GUESTROOM402_405_5_0_0_0_0 | W_GUESTROOM402_405_5_0_0_0_1 | W_GUESTROOM402_405_5_0_0_0_2 | W_GUESTROOM402_405_5_0_0_0_3 | W_GUESTROOM406_408_5_0_0_0_0 | W_GUESTROOM406_408_5_0_0_0_1 | W_GUESTROOM406_408_5_0_0_0_2 | W_GUESTROOM409_412_5_0_0_0_0 | W_GUESTROOM409_412_5_0_0_0_1 | W_GUESTROOM409_412_5_0_0_0_2 | W_GUESTROOM409_412_5_0_0_0_3 | W_GUESTROOM413_5_0_0_0_0 | W_GUESTROOM414_3_0_0_0_0 | W_GUESTROOM415_418_3_0_0_0_0 | W_GUESTROOM415_418_3_0_0_0_1 | W_GUESTROOM415_418_3_0_0_0_2 | W_GUESTROOM415_418_3_0_0_0_3 | W_GUESTROOM419_3_0_0_0_0 | W_GUESTROOM420_423_3_0_0_0_0 | W_GUESTROOM420_423_3_0_0_0_1 | W_GUESTROOM420_423_3_0_0_0_2 | W_GUESTROOM420_423_3_0_0_0_3 | W_GUESTROOM424_3_0_0_0_0 |WindowEnergyReportMonthly
| W_CORRIDORFLR1_2_0_0_0_0 | D_CORRIDORFLR1_16_0_0_0_0 | W_CORRIDORFLR1_20_0_0_0_0 | W_FRONTLOUNGEFLR1_5_0_0_0_0 | W_FRONTLOUNGEFLR1_5_0_0_0_1 | W_FRONTLOUNGEFLR1_5_0_0_0_2 | W_FRONTLOUNGEFLR1_5_0_0_0_3 | W_FRONTLOUNGEFLR1_5_0_0_0_4 | W_MEETINGROOMFLR1_5_0_0_0_0 | W_MEETINGROOMFLR1_5_0_0_0_1 | W_MEETINGROOMFLR1_5_0_0_0_2 | W_GUESTROOM101_5_0_0_0_0 | W_GUESTROOM102_5_0_0_0_0 | W_GUESTROOM103_5_0_0_0_0 | W_GUESTROOM104_3_0_0_0_0 | W_GUESTROOM105_3_0_0_0_0 | W_EMPLOYEELOUNGEFLR1_3_0_0_0_0 | W_LAUNDRYROOMFLR1_3_0_0_0_0 | W_LAUNDRYROOMFLR1_3_0_0_0_1 | W_LAUNDRYROOMFLR1_3_0_0_0_2 | W_EXERCISECENTERFLR1_3_0_0_0_0 | W_FRONTOFFICEFLR1_3_0_0_0_0 | W_FRONTOFFICEFLR1_3_0_0_0_1 | W_FRONTOFFICEFLR1_3_0_0_0_2 | W_FRONTOFFICEFLR1_3_0_0_0_3 | W_CORRIDORFLR2_2_0_0_0_0 | W_CORRIDORFLR2_15_0_0_0_0 | W_GUESTROOM201_5_0_0_0_0 | W_GUESTROOM202_205_5_0_0_0_0 | W_GUESTROOM202_205_5_0_0_0_1 | W_GUESTROOM202_205_5_0_0_0_2 | W_GUESTROOM202_205_5_0_0_0_3 | W_GUESTROOM206_208_5_0_0_0_0 | W_GUESTROOM206_208_5_0_0_0_1 | W_GUESTROOM206_208_5_0_0_0_2 | W_GUESTROOM209_212_5_0_0_0_0 | W_GUESTROOM209_212_5_0_0_0_1 | W_GUESTROOM209_212_5_0_0_0_2 | W_GUESTROOM209_212_5_0_0_0_3 | W_GUESTROOM213_5_0_0_0_0 | W_GUESTROOM214_3_0_0_0_0 | W_GUESTROOM215_218_3_0_0_0_0 | W_GUESTROOM215_218_3_0_0_0_1 | W_GUESTROOM215_218_3_0_0_0_2 | W_GUESTROOM215_218_3_0_0_0_3 | W_GUESTROOM219_3_0_0_0_0 | W_GUESTROOM220_223_3_0_0_0_0 | W_GUESTROOM220_223_3_0_0_0_1 | W_GUESTROOM220_223_3_0_0_0_2 | W_GUESTROOM220_223_3_0_0_0_3 | W_GUESTROOM224_3_0_0_0_0 | W_CORRIDORFLR3_2_0_0_0_0 | W_CORRIDORFLR3_15_0_0_0_0 | W_GUESTROOM301_5_0_0_0_0 | W_GUESTROOM302_305_5_0_0_0_0 | W_GUESTROOM302_305_5_0_0_0_1 | W_GUESTROOM302_305_5_0_0_0_2 | W_GUESTROOM302_305_5_0_0_0_3 | W_GUESTROOM306_308_5_0_0_0_0 | W_GUESTROOM306_308_5_0_0_0_1 | W_GUESTROOM306_308_5_0_0_0_2 | W_GUESTROOM309_312_5_0_0_0_0 | W_GUESTROOM309_312_5_0_0_0_1 | W_GUESTROOM309_312_5_0_0_0_2 | W_GUESTROOM309_312_5_0_0_0_3 | W_GUESTROOM313_5_0_0_0_0 | W_GUESTROOM314_3_0_0_0_0 | W_GUESTROOM315_318_3_0_0_0_0 | W_GUESTROOM315_318_3_0_0_0_1 | W_GUESTROOM315_318_3_0_0_0_2 | W_GUESTROOM315_318_3_0_0_0_3 | W_GUESTROOM319_3_0_0_0_0 | W_GUESTROOM320_323_3_0_0_0_0 | W_GUESTROOM320_323_3_0_0_0_1 | W_GUESTROOM320_323_3_0_0_0_2 | W_GUESTROOM320_323_3_0_0_0_3 | W_GUESTROOM324_3_0_0_0_0 | W_CORRIDORFLR4_2_0_0_0_0 | W_CORRIDORFLR4_15_0_0_0_0 | W_GUESTROOM401_5_0_0_0_0 | W_GUESTROOM402_405_5_0_0_0_0 | W_GUESTROOM402_405_5_0_0_0_1 | W_GUESTROOM402_405_5_0_0_0_2 | W_GUESTROOM402_405_5_0_0_0_3 | W_GUESTROOM406_408_5_0_0_0_0 | W_GUESTROOM406_408_5_0_0_0_1 | W_GUESTROOM406_408_5_0_0_0_2 | W_GUESTROOM409_412_5_0_0_0_0 | W_GUESTROOM409_412_5_0_0_0_1 | W_GUESTROOM409_412_5_0_0_0_2 | W_GUESTROOM409_412_5_0_0_0_3 | W_GUESTROOM413_5_0_0_0_0 | W_GUESTROOM414_3_0_0_0_0 | W_GUESTROOM415_418_3_0_0_0_0 | W_GUESTROOM415_418_3_0_0_0_1 | W_GUESTROOM415_418_3_0_0_0_2 | W_GUESTROOM415_418_3_0_0_0_3 | W_GUESTROOM419_3_0_0_0_0 | W_GUESTROOM420_423_3_0_0_0_0 | W_GUESTROOM420_423_3_0_0_0_1 | W_GUESTROOM420_423_3_0_0_0_2 | W_GUESTROOM420_423_3_0_0_0_3 | W_GUESTROOM424_3_0_0_0_0 |WindowZoneSummaryMonthly
| REARSTAIRSFLR1 | CORRIDORFLR1 | REARSTORAGEFLR1 | FRONTLOUNGEFLR1 | RESTROOMFLR1 | MEETINGROOMFLR1 | MECHANICALROOMFLR1 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | EMPLOYEELOUNGEFLR1 | LAUNDRYROOMFLR1 | ELEVATORCOREFLR1 | EXERCISECENTERFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | FRONTSTORAGEFLR1 | REARSTAIRSFLR2 | CORRIDORFLR2 | REARSTORAGEFLR2 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | ELEVATORCOREFLR2 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | FRONTSTORAGEFLR2 | FRONTSTAIRSFLR2 | REARSTAIRSFLR3 | CORRIDORFLR3 | REARSTORAGEFLR3 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | ELEVATORCOREFLR3 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | FRONTSTORAGEFLR3 | FRONTSTAIRSFLR3 | REARSTAIRSFLR4 | CORRIDORFLR4 | REARSTORAGEFLR4 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | ELEVATORCOREFLR4 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | FRONTSTORAGEFLR4 | FRONTSTAIRSFLR4 |WindowEnergyZoneSummaryMonthly
| REARSTAIRSFLR1 | CORRIDORFLR1 | REARSTORAGEFLR1 | FRONTLOUNGEFLR1 | RESTROOMFLR1 | MEETINGROOMFLR1 | MECHANICALROOMFLR1 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | EMPLOYEELOUNGEFLR1 | LAUNDRYROOMFLR1 | ELEVATORCOREFLR1 | EXERCISECENTERFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | FRONTSTORAGEFLR1 | REARSTAIRSFLR2 | CORRIDORFLR2 | REARSTORAGEFLR2 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | ELEVATORCOREFLR2 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | FRONTSTORAGEFLR2 | FRONTSTAIRSFLR2 | REARSTAIRSFLR3 | CORRIDORFLR3 | REARSTORAGEFLR3 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | ELEVATORCOREFLR3 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | FRONTSTORAGEFLR3 | FRONTSTAIRSFLR3 | REARSTAIRSFLR4 | CORRIDORFLR4 | REARSTORAGEFLR4 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | ELEVATORCOREFLR4 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | FRONTSTORAGEFLR4 | FRONTSTAIRSFLR4 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SHWSYSSHOWER WATER HEATER | SHWSYSLAUNDRY WATER HEATER |DaylightingReportMonthly
| FRONTLOUNGEFLR1_DAYLCTRL | MEETINGROOMFLR1_DAYLCTRL | FRONTOFFICEFLR1_DAYLCTRL | LAUNDRYROOMFLR1_DAYLCTRL |CoilReportMonthly
| 101 PTAC HEATING COIL | 102 PTAC HEATING COIL | 103 PTAC HEATING COIL | 104 PTAC HEATING COIL | 105 PTAC HEATING COIL | 201 PTAC HEATING COIL | 202_205 PTAC HEATING COIL | 206_208 PTAC HEATING COIL | 209_212 PTAC HEATING COIL | 213 PTAC HEATING COIL | 214 PTAC HEATING COIL | 215_218 PTAC HEATING COIL | 219 PTAC HEATING COIL | 220_223 PTAC HEATING COIL | 224 PTAC HEATING COIL | 301 PTAC HEATING COIL | 302_305 PTAC HEATING COIL | 306_308 PTAC HEATING COIL | 309_312 PTAC HEATING COIL | 313 PTAC HEATING COIL | 314 PTAC HEATING COIL | 315_318 PTAC HEATING COIL | 319 PTAC HEATING COIL | 320_323 PTAC HEATING COIL | 324 PTAC HEATING COIL | 401 PTAC HEATING COIL | 402_405 PTAC HEATING COIL | 406_408 PTAC HEATING COIL | 409_412 PTAC HEATING COIL | 413 PTAC HEATING COIL | 414 PTAC HEATING COIL | 415_418 PTAC HEATING COIL | 419 PTAC HEATING COIL | 420_423 PTAC HEATING COIL | 424 PTAC HEATING COIL | CORRIDORFLR1 PTAC HEATING COIL | CORRIDORFLR2 PTAC HEATING COIL | CORRIDORFLR3 PTAC HEATING COIL | CORRIDORFLR4 PTAC HEATING COIL | MECHRMUNITHEATERHEATINGCOIL | REARSTAIRSFLR1UNITHEATERHEATINGCOIL | FRONTSTAIRSFLR1UNITHEATERHEATINGCOIL | REARSTAIRSFLR2UNITHEATERHEATINGCOIL | FRONTSTAIRSFLR2UNITHEATERHEATINGCOIL | REARSTAIRSFLR3UNITHEATERHEATINGCOIL | FRONTSTAIRSFLR3UNITHEATERHEATINGCOIL | REARSTAIRSFLR4UNITHEATERHEATINGCOIL | FRONTSTAIRSFLR4UNITHEATERHEATINGCOIL | SAC_FRONTOFFICE HEATING COIL | SAC_FRONTLOUNGE HEATING COIL | SAC_MEETINGROOM HEATING COIL | SAC_EXC_EMPLGE_RESTRM HEATING COIL | 101 PTAC COOLING COIL | 102 PTAC COOLING COIL | 103 PTAC COOLING COIL | 104 PTAC COOLING COIL | 105 PTAC COOLING COIL | 201 PTAC COOLING COIL | 202_205 PTAC COOLING COIL | 206_208 PTAC COOLING COIL | 209_212 PTAC COOLING COIL | 213 PTAC COOLING COIL | 214 PTAC COOLING COIL | 215_218 PTAC COOLING COIL | 219 PTAC COOLING COIL | 220_223 PTAC COOLING COIL | 224 PTAC COOLING COIL | 301 PTAC COOLING COIL | 302_305 PTAC COOLING COIL | 306_308 PTAC COOLING COIL | 309_312 PTAC COOLING COIL | 313 PTAC COOLING COIL | 314 PTAC COOLING COIL | 315_318 PTAC COOLING COIL | 319 PTAC COOLING COIL | 320_323 PTAC COOLING COIL | 324 PTAC COOLING COIL | 401 PTAC COOLING COIL | 402_405 PTAC COOLING COIL | 406_408 PTAC COOLING COIL | 409_412 PTAC COOLING COIL | 413 PTAC COOLING COIL | 414 PTAC COOLING COIL | 415_418 PTAC COOLING COIL | 419 PTAC COOLING COIL | 420_423 PTAC COOLING COIL | 424 PTAC COOLING COIL | CORRIDORFLR1 PTAC COOLING COIL | CORRIDORFLR2 PTAC COOLING COIL | CORRIDORFLR3 PTAC COOLING COIL | CORRIDORFLR4 PTAC COOLING COIL | SAC_FRONTOFFICE COOLING COIL | SAC_FRONTLOUNGE COOLING COIL | SAC_MEETINGROOM COOLING COIL | SAC_EXC_EMPLGE_RESTRM COOLING COIL |PlantLoopDemandReportMonthly
| SHWSYSSHOWER | SHWSYSLAUNDRY |FanReportMonthly
| MECHRMUNITHEATERFAN | REARSTAIRSFLR1UNITHEATERFAN | FRONTSTAIRSFLR1UNITHEATERFAN | REARSTAIRSFLR2UNITHEATERFAN | FRONTSTAIRSFLR2UNITHEATERFAN | REARSTAIRSFLR3UNITHEATERFAN | FRONTSTAIRSFLR3UNITHEATERFAN | REARSTAIRSFLR4UNITHEATERFAN | FRONTSTAIRSFLR4UNITHEATERFAN | 101 PTAC SUPPLY FAN | 102 PTAC SUPPLY FAN | 103 PTAC SUPPLY FAN | 104 PTAC SUPPLY FAN | 105 PTAC SUPPLY FAN | 201 PTAC SUPPLY FAN | 202_205 PTAC SUPPLY FAN | 206_208 PTAC SUPPLY FAN | 209_212 PTAC SUPPLY FAN | 213 PTAC SUPPLY FAN | 214 PTAC SUPPLY FAN | 215_218 PTAC SUPPLY FAN | 219 PTAC SUPPLY FAN | 220_223 PTAC SUPPLY FAN | 224 PTAC SUPPLY FAN | 301 PTAC SUPPLY FAN | 302_305 PTAC SUPPLY FAN | 306_308 PTAC SUPPLY FAN | 309_312 PTAC SUPPLY FAN | 313 PTAC SUPPLY FAN | 314 PTAC SUPPLY FAN | 315_318 PTAC SUPPLY FAN | 319 PTAC SUPPLY FAN | 320_323 PTAC SUPPLY FAN | 324 PTAC SUPPLY FAN | 401 PTAC SUPPLY FAN | 402_405 PTAC SUPPLY FAN | 406_408 PTAC SUPPLY FAN | 409_412 PTAC SUPPLY FAN | 413 PTAC SUPPLY FAN | 414 PTAC SUPPLY FAN | 415_418 PTAC SUPPLY FAN | 419 PTAC SUPPLY FAN | 420_423 PTAC SUPPLY FAN | 424 PTAC SUPPLY FAN | CORRIDORFLR1 PTAC SUPPLY FAN | CORRIDORFLR2 PTAC SUPPLY FAN | CORRIDORFLR3 PTAC SUPPLY FAN | CORRIDORFLR4 PTAC SUPPLY FAN | SAC_FO_ADDAQ SUPPLY FAN | SAC_FL_ADDAQ SUPPLY FAN | SAC_MR_ADDAQ SUPPLY FAN | SAC_EXC_ADDAQ SUPPLY FAN |PumpReportMonthly
| SHWSYSSHOWER PUMP | SHWSYSLAUNDRY PUMP |CondLoopDemandReportMonthly
| SHWSYSSHOWER | SHWSYSLAUNDRY |ZoneTemperatureOscillationReportMonthly
| REARSTAIRSFLR1 | CORRIDORFLR1 | REARSTORAGEFLR1 | FRONTLOUNGEFLR1 | RESTROOMFLR1 | MEETINGROOMFLR1 | MECHANICALROOMFLR1 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | EMPLOYEELOUNGEFLR1 | LAUNDRYROOMFLR1 | ELEVATORCOREFLR1 | EXERCISECENTERFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | FRONTSTORAGEFLR1 | REARSTAIRSFLR2 | CORRIDORFLR2 | REARSTORAGEFLR2 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | ELEVATORCOREFLR2 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | FRONTSTORAGEFLR2 | FRONTSTAIRSFLR2 | REARSTAIRSFLR3 | CORRIDORFLR3 | REARSTORAGEFLR3 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | ELEVATORCOREFLR3 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | FRONTSTORAGEFLR3 | FRONTSTAIRSFLR3 | REARSTAIRSFLR4 | CORRIDORFLR4 | REARSTORAGEFLR4 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | ELEVATORCOREFLR4 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | FRONTSTORAGEFLR4 | FRONTSTAIRSFLR4 |AirLoopSystemEnergyAndWaterUseMonthly
| SAC_FRONTOFFICE | SAC_FRONTLOUNGE | SAC_MEETINGROOM | SAC_EXC_EMPLGE_RESTRM |AirLoopSystemComponentLoadsMonthly
| SAC_FRONTOFFICE | SAC_FRONTLOUNGE | SAC_MEETINGROOM | SAC_EXC_EMPLGE_RESTRM |AirLoopSystemComponentEnergyUseMonthly
| SAC_FRONTOFFICE | SAC_FRONTLOUNGE | SAC_MEETINGROOM | SAC_EXC_EMPLGE_RESTRM |MechanicalVentilationLoadsMonthly
| REARSTAIRSFLR1 | CORRIDORFLR1 | FRONTLOUNGEFLR1 | RESTROOMFLR1 | MEETINGROOMFLR1 | MECHANICALROOMFLR1 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | EMPLOYEELOUNGEFLR1 | EXERCISECENTERFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | REARSTAIRSFLR2 | CORRIDORFLR2 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | FRONTSTAIRSFLR2 | REARSTAIRSFLR3 | CORRIDORFLR3 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | FRONTSTAIRSFLR3 | REARSTAIRSFLR4 | CORRIDORFLR4 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | FRONTSTAIRSFLR4 |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 20:15:15
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 20:14 |
RunPeriod | RUNPERIOD 1 |
Weather File | Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745 |
Latitude [deg] | 32.17 |
Longitude [deg] | -110.9 |
Elevation [m] | 809.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 180.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1694.58 | 635.46 | 211.83 | 635.46 | 211.83 |
Above Ground Wall Area [m2] | 1694.58 | 635.46 | 211.83 | 635.46 | 211.83 |
Window Opening Area [m2] | 184.20 | 96.82 | 8.38 | 72.38 | 6.62 |
Gross Window-Wall Ratio [%] | 10.87 | 15.24 | 3.95 | 11.39 | 3.13 |
Above Ground Window-Wall Ratio [%] | 10.87 | 15.24 | 3.95 | 11.39 | 3.13 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1492.32 | 607.21 | 211.83 | 556.77 | 116.50 |
Above Ground Wall Area [m2] | 1492.32 | 607.21 | 211.83 | 556.77 | 116.50 |
Window Opening Area [m2] | 179.26 | 96.82 | 8.38 | 67.45 | 6.62 |
Gross Window-Wall Ratio [%] | 12.01 | 15.95 | 3.95 | 12.11 | 5.68 |
Above Ground Window-Wall Ratio [%] | 12.01 | 15.95 | 3.95 | 12.11 | 5.68 |
Total | |
Gross Roof Area [m2] | 1003.40 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
REARSTAIRSFLR1 | 20.07 | Yes | Yes | 67.30 | 1.00 | 35.77 | 0.00 | 0.00 | 0.00 | 5.2743 | 0.0000 | |
CORRIDORFLR1 | 150.51 | Yes | Yes | 504.62 | 1.00 | 32.70 | 0.00 | 9.82 | 9.82 | 5.2958 | 0.0000 | |
REARSTORAGEFLR1 | 20.07 | No | Yes | 67.30 | 1.00 | 35.77 | 0.00 | 0.00 | 0.00 | 4.0903 | 0.0000 | |
FRONTLOUNGEFLR1 | 163.06 | Yes | Yes | 546.70 | 1.00 | 94.02 | 0.00 | 14.83 | 14.83 | 5.4896 | 3.08 | 26.0600 |
RESTROOMFLR1 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 0.00 | 0.00 | 0.00 | 6.7813 | 32.61 | 0.0000 |
MEETINGROOMFLR1 | 80.27 | Yes | Yes | 269.14 | 1.00 | 32.70 | 0.00 | 4.94 | 4.94 | 10.4410 | 1.87 | 6.1800 |
MECHANICALROOMFLR1 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 0.00 | 0.00 | 0.00 | 10.2257 | 0.0000 | |
GUESTROOM101 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM102 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM103 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM104 | 32.61 | Yes | Yes | 109.33 | 1.00 | 13.29 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM105 | 32.61 | Yes | Yes | 109.33 | 1.00 | 13.29 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
EMPLOYEELOUNGEFLR1 | 32.61 | Yes | Yes | 109.33 | 1.00 | 13.29 | 0.00 | 1.65 | 1.65 | 4.5208 | 1.81 | 21.5100 |
LAUNDRYROOMFLR1 | 97.83 | No | Yes | 327.99 | 1.00 | 39.86 | 0.00 | 4.94 | 4.94 | 5.7049 | 8.89 | 437.5596 |
ELEVATORCOREFLR1 | 15.05 | No | Yes | 50.46 | 1.00 | 6.13 | 0.00 | 0.00 | 0.00 | 0.0000 | 2141.8115 | |
EXERCISECENTERFLR1 | 32.61 | Yes | Yes | 109.33 | 1.00 | 13.29 | 0.00 | 1.65 | 1.65 | 11.6250 | 4.66 | 18.5900 |
FRONTOFFICEFLR1 | 130.44 | Yes | Yes | 437.33 | 1.00 | 53.14 | 0.00 | 6.58 | 6.58 | 7.9653 | 13.04 | 13.7800 |
FRONTSTAIRSFLR1 | 20.07 | Yes | Yes | 67.28 | 1.00 | 35.77 | 0.00 | 0.00 | 0.00 | 5.2743 | 0.0000 | |
FRONTSTORAGEFLR1 | 12.54 | No | Yes | 42.05 | 1.00 | 5.11 | 0.00 | 0.00 | 0.00 | 4.0903 | 0.0000 | |
REARSTAIRSFLR2 | 20.07 | Yes | Yes | 55.06 | 1.00 | 29.27 | 0.00 | 0.00 | 0.00 | 5.2743 | 0.0000 | |
CORRIDORFLR2 | 125.42 | Yes | Yes | 344.05 | 1.00 | 18.39 | 0.00 | 2.62 | 2.62 | 5.2958 | 0.0000 | |
REARSTORAGEFLR2 | 20.07 | No | Yes | 55.07 | 1.00 | 29.27 | 0.00 | 0.00 | 0.00 | 4.0903 | 0.0000 | |
GUESTROOM201 | 32.61 | Yes | Yes | 89.46 | 1.00 | 33.45 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM202_205 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 0.00 | 6.58 | 6.58 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM206_208 | 105.36 | Yes | Yes | 289.02 | 1.00 | 35.12 | 0.00 | 6.70 | 6.70 | 4.4132 | 23.41 | 11.8935 |
GUESTROOM209_212 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 0.00 | 6.58 | 6.58 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM213 | 32.61 | Yes | Yes | 89.46 | 1.00 | 10.87 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM214 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM215_218 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 0.00 | 6.58 | 6.58 | 4.4132 | 21.74 | 11.8935 |
ELEVATORCOREFLR2 | 15.05 | No | Yes | 41.29 | 1.00 | 5.02 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
GUESTROOM219 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM220_223 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 0.00 | 6.58 | 6.58 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM224 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
FRONTSTORAGEFLR2 | 12.54 | No | Yes | 34.40 | 1.00 | 4.18 | 0.00 | 0.00 | 0.00 | 4.0903 | 0.0000 | |
FRONTSTAIRSFLR2 | 20.07 | Yes | Yes | 55.05 | 1.00 | 29.26 | 0.00 | 0.00 | 0.00 | 5.2743 | 0.0000 | |
REARSTAIRSFLR3 | 20.07 | Yes | Yes | 55.06 | 1.00 | 29.27 | 0.00 | 0.00 | 0.00 | 5.2743 | 0.0000 | |
CORRIDORFLR3 | 125.42 | Yes | Yes | 344.05 | 1.00 | 18.39 | 0.00 | 2.62 | 2.62 | 5.2958 | 0.0000 | |
REARSTORAGEFLR3 | 20.07 | No | Yes | 55.07 | 1.00 | 29.27 | 0.00 | 0.00 | 0.00 | 4.0903 | 0.0000 | |
GUESTROOM301 | 32.61 | Yes | Yes | 89.46 | 1.00 | 33.45 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM302_305 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 0.00 | 6.58 | 6.58 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM306_308 | 105.36 | Yes | Yes | 289.02 | 1.00 | 35.12 | 0.00 | 6.70 | 6.70 | 4.4132 | 23.41 | 11.8935 |
GUESTROOM309_312 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 0.00 | 6.58 | 6.58 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM313 | 32.61 | Yes | Yes | 89.46 | 1.00 | 10.87 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM314 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM315_318 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 0.00 | 6.58 | 6.58 | 4.4132 | 21.74 | 11.8935 |
ELEVATORCOREFLR3 | 15.05 | No | Yes | 41.29 | 1.00 | 5.02 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
GUESTROOM319 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM320_323 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 0.00 | 6.58 | 6.58 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM324 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
FRONTSTORAGEFLR3 | 12.54 | No | Yes | 34.40 | 1.00 | 4.18 | 0.00 | 0.00 | 0.00 | 4.0903 | 0.0000 | |
FRONTSTAIRSFLR3 | 20.07 | Yes | Yes | 55.05 | 1.00 | 29.26 | 0.00 | 0.00 | 0.00 | 5.2743 | 0.0000 | |
REARSTAIRSFLR4 | 20.07 | Yes | Yes | 55.06 | 1.00 | 29.27 | 0.00 | 0.00 | 0.00 | 5.2743 | 0.0000 | |
CORRIDORFLR4 | 125.42 | Yes | Yes | 344.05 | 1.00 | 18.39 | 0.00 | 2.62 | 2.62 | 5.2958 | 0.0000 | |
REARSTORAGEFLR4 | 20.07 | No | Yes | 55.07 | 1.00 | 29.27 | 0.00 | 0.00 | 0.00 | 4.0903 | 0.0000 | |
GUESTROOM401 | 32.61 | Yes | Yes | 89.46 | 1.00 | 33.45 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM402_405 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 0.00 | 6.58 | 6.58 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM406_408 | 105.36 | Yes | Yes | 289.02 | 1.00 | 35.12 | 0.00 | 6.70 | 6.70 | 4.4132 | 23.41 | 11.8935 |
GUESTROOM409_412 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 0.00 | 6.58 | 6.58 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM413 | 32.61 | Yes | Yes | 89.46 | 1.00 | 10.87 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM414 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM415_418 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 0.00 | 6.58 | 6.58 | 4.4132 | 21.74 | 11.8935 |
ELEVATORCOREFLR4 | 15.05 | No | Yes | 41.29 | 1.00 | 5.02 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
GUESTROOM419 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM420_423 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 0.00 | 6.58 | 6.58 | 4.4132 | 21.74 | 11.8935 |
GUESTROOM424 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 0.00 | 1.65 | 1.65 | 4.4132 | 21.74 | 11.8935 |
FRONTSTORAGEFLR4 | 12.54 | No | Yes | 34.40 | 1.00 | 4.18 | 0.00 | 0.00 | 0.00 | 4.0903 | 0.0000 | |
FRONTSTAIRSFLR4 | 20.07 | Yes | Yes | 55.05 | 1.00 | 29.26 | 0.00 | 0.00 | 0.00 | 5.2743 | 0.0000 | |
Total | 4013.58 | 11621.73 | 1694.58 | 0.00 | 184.20 | 184.20 | 4.9239 | 15.53 | 28.1602 | |||
Conditioned Total | 3725.09 | 10741.65 | 1492.32 | 0.00 | 179.26 | 179.26 | 5.0122 | 15.05 | 10.1966 | |||
Unconditioned Total | 288.49 | 880.07 | 202.26 | 0.00 | 4.94 | 4.94 | 3.7842 | 26.23 | 260.1140 | |||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 20:15:15
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 18-JUL-06:49 | 28-JAN-09:20 | - | - | - | 01-JAN-08:09 |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 37483.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 7209.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 39412.07 | 40096.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 6213.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 8.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 67328.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 90327.43 | 107424.69 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 37483.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 7209.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 23294.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 16054.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 62.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Laundry | 0.00 | 40096.03 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 6213.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 8.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 67328.67 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 20:15:15
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 18.04 | 2.59 | 0.00 | 0.00 | 0.00 |
Cooling | 1269.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 587.95 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 140.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1766.12 | 456.89 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 530.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.81 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 524.71 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4312.99 | 984.19 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 4.84 | 0.70 | 0.00 | 0.00 | 0.00 |
Cooling | 340.82 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 157.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 37.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 474.11 | 122.65 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 142.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 140.86 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1157.82 | 264.21 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 4.84 | 0.70 | 0.00 | 0.00 | 0.00 |
Cooling | 340.82 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 157.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 37.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 474.11 | 122.65 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 142.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 140.86 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1157.82 | 264.21 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 20:15:15
ZoneHVAC:UnitHeaterDesign Size Maximum Supply Air Flow Rate [m3/s] | |
REARSTAIRSFLR1 UNITHEATER | 0.006116 |
MECHRM UNITHEATER | 0.000000 |
FRONTSTAIRSFLR1 UNITHEATER | 0.006114 |
REARSTAIRSFLR2 UNITHEATER | 0.006116 |
FRONTSTAIRSFLR2 UNITHEATER | 0.006114 |
REARSTAIRSFLR3 UNITHEATER | 0.006116 |
FRONTSTAIRSFLR3 UNITHEATER | 0.006114 |
REARSTAIRSFLR4 UNITHEATER | 0.006116 |
FRONTSTAIRSFLR4 UNITHEATER | 0.006114 |
Design Size Maximum Flow Rate [m3/s] | |
REARSTAIRSFLR1UNITHEATERFAN | 0.006116 |
MECHRMUNITHEATERFAN | 0.000000 |
FRONTSTAIRSFLR1UNITHEATERFAN | 0.006114 |
REARSTAIRSFLR2UNITHEATERFAN | 0.006116 |
FRONTSTAIRSFLR2UNITHEATERFAN | 0.006114 |
REARSTAIRSFLR3UNITHEATERFAN | 0.006116 |
FRONTSTAIRSFLR3UNITHEATERFAN | 0.006114 |
REARSTAIRSFLR4UNITHEATERFAN | 0.006116 |
FRONTSTAIRSFLR4UNITHEATERFAN | 0.006114 |
Design Size Nominal Capacity [W] | |
REARSTAIRSFLR1UNITHEATERHEATINGCOIL | 291.78 |
CORRIDORFLR1 PTAC HEATING COIL | 27932.61 |
MECHRMUNITHEATERHEATINGCOIL | 0.000000 |
101 PTAC HEATING COIL | 743.50 |
102 PTAC HEATING COIL | 743.50 |
103 PTAC HEATING COIL | 743.50 |
104 PTAC HEATING COIL | 743.45 |
105 PTAC HEATING COIL | 743.45 |
FRONTSTAIRSFLR1UNITHEATERHEATINGCOIL | 291.71 |
REARSTAIRSFLR2UNITHEATERHEATINGCOIL | 291.78 |
CORRIDORFLR2 PTAC HEATING COIL | 2108.60 |
201 PTAC HEATING COIL | 743.50 |
202_205 PTAC HEATING COIL | 2973.99 |
206_208 PTAC HEATING COIL | 2356.99 |
209_212 PTAC HEATING COIL | 2973.99 |
213 PTAC HEATING COIL | 743.50 |
214 PTAC HEATING COIL | 743.45 |
215_218 PTAC HEATING COIL | 2973.78 |
219 PTAC HEATING COIL | 743.45 |
220_223 PTAC HEATING COIL | 2973.78 |
224 PTAC HEATING COIL | 743.45 |
FRONTSTAIRSFLR2UNITHEATERHEATINGCOIL | 291.71 |
REARSTAIRSFLR3UNITHEATERHEATINGCOIL | 291.78 |
CORRIDORFLR3 PTAC HEATING COIL | 2108.60 |
301 PTAC HEATING COIL | 743.50 |
302_305 PTAC HEATING COIL | 2973.99 |
306_308 PTAC HEATING COIL | 2356.99 |
309_312 PTAC HEATING COIL | 2973.99 |
313 PTAC HEATING COIL | 743.50 |
314 PTAC HEATING COIL | 743.45 |
315_318 PTAC HEATING COIL | 2973.78 |
319 PTAC HEATING COIL | 743.45 |
320_323 PTAC HEATING COIL | 2973.78 |
324 PTAC HEATING COIL | 743.45 |
FRONTSTAIRSFLR3UNITHEATERHEATINGCOIL | 291.71 |
REARSTAIRSFLR4UNITHEATERHEATINGCOIL | 291.78 |
CORRIDORFLR4 PTAC HEATING COIL | 2264.62 |
401 PTAC HEATING COIL | 825.23 |
402_405 PTAC HEATING COIL | 2973.99 |
406_408 PTAC HEATING COIL | 2356.99 |
409_412 PTAC HEATING COIL | 2973.99 |
413 PTAC HEATING COIL | 892.86 |
414 PTAC HEATING COIL | 858.47 |
415_418 PTAC HEATING COIL | 2973.78 |
419 PTAC HEATING COIL | 743.45 |
420_423 PTAC HEATING COIL | 2973.78 |
424 PTAC HEATING COIL | 825.84 |
FRONTSTAIRSFLR4UNITHEATERHEATINGCOIL | 291.71 |
Design Size Cooling Supply Air Flow Rate [m3/s] | User-Specified Cooling Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | User-Specified Heating Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified No Load Supply Air Flow Rate [m3/s] | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | |
CORRIDORFLR1 PTAC | 3.51 | 0.129800 | 3.51 | 0.129800 | 3.51 | 0.129800 | 0.045856 | 0.045870 | 0.045856 | 0.045870 | 0.045856 | 0.045870 |
101 PTAC | 0.129800 | 0.129800 | 0.129800 | 0.013474 | 0.013478 | 0.013474 | 0.013478 | 0.013474 | 0.013478 | |||
102 PTAC | 0.100750 | 0.129800 | 0.100750 | 0.129800 | 0.100750 | 0.129800 | 0.013474 | 0.013478 | 0.013474 | 0.013478 | 0.013474 | 0.013478 |
103 PTAC | 0.200892 | 0.129800 | 0.200892 | 0.129800 | 0.200892 | 0.129800 | 0.013474 | 0.013478 | 0.013474 | 0.013478 | 0.013474 | 0.013478 |
104 PTAC | 0.217999 | 0.129800 | 0.217999 | 0.129800 | 0.217999 | 0.129800 | 0.013473 | 0.013478 | 0.013473 | 0.013478 | 0.013473 | 0.013478 |
105 PTAC | 0.290754 | 0.129800 | 0.290754 | 0.129800 | 0.290754 | 0.129800 | 0.013473 | 0.013478 | 0.013473 | 0.013478 | 0.013473 | 0.013478 |
CORRIDORFLR2 PTAC | 0.327595 | 0.129800 | 0.327595 | 0.129800 | 0.327595 | 0.129800 | 0.038213 | 0.038225 | 0.038213 | 0.038225 | 0.038213 | 0.038225 |
201 PTAC | 0.147002 | 0.129800 | 0.147002 | 0.129800 | 0.147002 | 0.129800 | 0.013474 | 0.013478 | 0.013474 | 0.013478 | 0.013474 | 0.013478 |
202_205 PTAC | 0.626985 | 0.519200 | 0.626985 | 0.519200 | 0.626985 | 0.519200 | 0.053896 | 0.053911 | 0.053896 | 0.053911 | 0.053896 | 0.053911 |
206_208 PTAC | 0.513169 | 0.389400 | 0.513169 | 0.389400 | 0.513169 | 0.389400 | 0.042715 | 0.042731 | 0.042715 | 0.042731 | 0.042715 | 0.042731 |
209_212 PTAC | 0.598086 | 0.519200 | 0.598086 | 0.519200 | 0.598086 | 0.519200 | 0.053896 | 0.053911 | 0.053896 | 0.053911 | 0.053896 | 0.053911 |
213 PTAC | 0.174217 | 0.129800 | 0.174217 | 0.129800 | 0.174217 | 0.129800 | 0.013474 | 0.013478 | 0.013474 | 0.013478 | 0.013474 | 0.013478 |
214 PTAC | 0.206626 | 0.129800 | 0.206626 | 0.129800 | 0.206626 | 0.129800 | 0.013473 | 0.013478 | 0.013473 | 0.013478 | 0.013473 | 0.013478 |
215_218 PTAC | 2.01 | 0.519200 | 2.01 | 0.519200 | 2.01 | 0.519200 | 0.053893 | 0.053911 | 0.053893 | 0.053911 | 0.053893 | 0.053911 |
219 PTAC | 1.12 | 0.129800 | 1.12 | 0.129800 | 1.12 | 0.129800 | 0.013473 | 0.013478 | 0.013473 | 0.013478 | 0.013473 | 0.013478 |
220_223 PTAC | 0.648893 | 0.519200 | 0.648893 | 0.519200 | 0.648893 | 0.519200 | 0.053893 | 0.053911 | 0.053893 | 0.053911 | 0.053893 | 0.053911 |
224 PTAC | 0.192451 | 0.129800 | 0.192451 | 0.129800 | 0.192451 | 0.129800 | 0.013473 | 0.013478 | 0.013473 | 0.013478 | 0.013473 | 0.013478 |
CORRIDORFLR3 PTAC | 0.106736 | 0.129800 | 0.106736 | 0.129800 | 0.106736 | 0.129800 | 0.038213 | 0.038225 | 0.038213 | 0.038225 | 0.038213 | 0.038225 |
301 PTAC | 0.116806 | 0.129800 | 0.116806 | 0.129800 | 0.116806 | 0.129800 | 0.013474 | 0.013478 | 0.013474 | 0.013478 | 0.013474 | 0.013478 |
302_305 PTAC | 0.251015 | 0.519200 | 0.251015 | 0.519200 | 0.251015 | 0.519200 | 0.053896 | 0.053911 | 0.053896 | 0.053911 | 0.053896 | 0.053911 |
306_308 PTAC | 0.216233 | 0.389400 | 0.216233 | 0.389400 | 0.216233 | 0.389400 | 0.042715 | 0.042731 | 0.042715 | 0.042731 | 0.042715 | 0.042731 |
309_312 PTAC | 0.519200 | 0.519200 | 0.519200 | 0.053896 | 0.053911 | 0.053896 | 0.053911 | 0.053896 | 0.053911 | |||
313 PTAC | 0.101125 | 0.129800 | 0.101125 | 0.129800 | 0.101125 | 0.129800 | 0.013474 | 0.013478 | 0.013474 | 0.013478 | 0.013474 | 0.013478 |
314 PTAC | 0.181048 | 0.129800 | 0.181048 | 0.129800 | 0.181048 | 0.129800 | 0.013473 | 0.013478 | 0.013473 | 0.013478 | 0.013473 | 0.013478 |
315_318 PTAC | 0.745273 | 0.519200 | 0.745273 | 0.519200 | 0.745273 | 0.519200 | 0.053893 | 0.053911 | 0.053893 | 0.053911 | 0.053893 | 0.053911 |
319 PTAC | 0.185710 | 0.129800 | 0.185710 | 0.129800 | 0.185710 | 0.129800 | 0.013473 | 0.013478 | 0.013473 | 0.013478 | 0.013473 | 0.013478 |
320_323 PTAC | 0.585657 | 0.519200 | 0.585657 | 0.519200 | 0.585657 | 0.519200 | 0.053893 | 0.053911 | 0.053893 | 0.053911 | 0.053893 | 0.053911 |
324 PTAC | 0.106646 | 0.129800 | 0.106646 | 0.129800 | 0.106646 | 0.129800 | 0.013473 | 0.013478 | 0.013473 | 0.013478 | 0.013473 | 0.013478 |
CORRIDORFLR4 PTAC | 0.159426 | 0.129800 | 0.159426 | 0.129800 | 0.159426 | 0.129800 | 0.038213 | 0.038225 | 0.038213 | 0.038225 | 0.038213 | 0.038225 |
401 PTAC | 0.224709 | 0.129800 | 0.224709 | 0.129800 | 0.224709 | 0.129800 | 0.013474 | 0.013478 | 0.013474 | 0.013478 | 0.013474 | 0.013478 |
402_405 PTAC | 0.335748 | 0.519200 | 0.335748 | 0.519200 | 0.335748 | 0.519200 | 0.053896 | 0.053911 | 0.053896 | 0.053911 | 0.053896 | 0.053911 |
406_408 PTAC | 0.285235 | 0.389400 | 0.285235 | 0.389400 | 0.285235 | 0.389400 | 0.042715 | 0.042731 | 0.042715 | 0.042731 | 0.042715 | 0.042731 |
409_412 PTAC | 0.679322 | 0.519200 | 0.679322 | 0.519200 | 0.679322 | 0.519200 | 0.053896 | 0.053911 | 0.053896 | 0.053911 | 0.053896 | 0.053911 |
413 PTAC | 0.129800 | 0.129800 | 0.129800 | 0.013474 | 0.013478 | 0.013474 | 0.013478 | 0.013474 | 0.013478 | |||
414 PTAC | 0.143501 | 0.129800 | 0.143501 | 0.129800 | 0.143501 | 0.129800 | 0.013473 | 0.013478 | 0.013473 | 0.013478 | 0.013473 | 0.013478 |
415_418 PTAC | 0.732602 | 0.519200 | 0.732602 | 0.519200 | 0.732602 | 0.519200 | 0.053893 | 0.053911 | 0.053893 | 0.053911 | 0.053893 | 0.053911 |
419 PTAC | 0.206876 | 0.129800 | 0.206876 | 0.129800 | 0.206876 | 0.129800 | 0.013473 | 0.013478 | 0.013473 | 0.013478 | 0.013473 | 0.013478 |
420_423 PTAC | 0.713647 | 0.519200 | 0.713647 | 0.519200 | 0.713647 | 0.519200 | 0.053893 | 0.053911 | 0.053893 | 0.053911 | 0.053893 | 0.053911 |
424 PTAC | 0.210921 | 0.129800 | 0.210921 | 0.129800 | 0.210921 | 0.129800 | 0.013473 | 0.013478 | 0.013473 | 0.013478 | 0.013473 | 0.013478 |
User-Specified Rated Air Flow Rate [m3/s] | Design Size Gross Rated Total Cooling Capacity [W] | User-Specified Gross Rated Total Cooling Capacity [W] | Design Size Gross Rated Sensible Heat Ratio | |
CORRIDORFLR1 PTAC COOLING COIL | 0.129800 | 1851.63 | 2637.75 | 0.766484 |
101 PTAC COOLING COIL | 0.129800 | 1752.38 | 2637.75 | 0.766484 |
102 PTAC COOLING COIL | 0.129800 | 1843.34 | 2637.75 | 0.766484 |
103 PTAC COOLING COIL | 0.129800 | 1540.03 | 2637.75 | 0.766484 |
104 PTAC COOLING COIL | 0.129800 | 1593.95 | 2637.75 | 0.766484 |
105 PTAC COOLING COIL | 0.129800 | 1571.97 | 2637.75 | 0.766484 |
CORRIDORFLR2 PTAC COOLING COIL | 0.129800 | 2100.45 | 2637.75 | 0.766484 |
201 PTAC COOLING COIL | 0.129800 | 1734.42 | 2637.75 | 0.766484 |
202_205 PTAC COOLING COIL | 0.519200 | 6769.88 | 10551.00 | 0.766484 |
206_208 PTAC COOLING COIL | 0.389400 | 5054.49 | 7913.25 | 0.766484 |
209_212 PTAC COOLING COIL | 0.519200 | 6819.83 | 10551.00 | 0.766484 |
213 PTAC COOLING COIL | 0.129800 | 1576.54 | 2637.75 | 0.766484 |
214 PTAC COOLING COIL | 0.129800 | 1603.86 | 2637.75 | 0.766484 |
215_218 PTAC COOLING COIL | 0.519200 | 6058.43 | 10551.00 | 0.766484 |
219 PTAC COOLING COIL | 0.129800 | 1465.63 | 2637.75 | 0.766484 |
220_223 PTAC COOLING COIL | 0.519200 | 6754.02 | 10551.00 | 0.766484 |
224 PTAC COOLING COIL | 0.129800 | 1644.27 | 2637.75 | 0.766484 |
CORRIDORFLR3 PTAC COOLING COIL | 0.129800 | 2637.75 | 0.766484 | |
301 PTAC COOLING COIL | 0.129800 | 1825.80 | 2637.75 | 0.766484 |
302_305 PTAC COOLING COIL | 0.519200 | 8338.17 | 10551.00 | 0.766484 |
306_308 PTAC COOLING COIL | 0.389400 | 6103.49 | 7913.25 | 0.766484 |
309_312 PTAC COOLING COIL | 0.519200 | 6858.93 | 10551.00 | 0.766484 |
313 PTAC COOLING COIL | 0.129800 | 1717.16 | 2637.75 | 0.766484 |
314 PTAC COOLING COIL | 0.129800 | 1624.81 | 2637.75 | 0.766484 |
315_318 PTAC COOLING COIL | 0.519200 | 6606.26 | 10551.00 | 0.766484 |
319 PTAC COOLING COIL | 0.129800 | 1655.80 | 2637.75 | 0.766484 |
320_323 PTAC COOLING COIL | 0.519200 | 6844.32 | 10551.00 | 0.766484 |
324 PTAC COOLING COIL | 0.129800 | 1821.55 | 2637.75 | 0.766484 |
CORRIDORFLR4 PTAC COOLING COIL | 0.129800 | 2637.75 | 0.766484 | |
401 PTAC COOLING COIL | 0.129800 | 1633.36 | 2637.75 | 0.766484 |
402_405 PTAC COOLING COIL | 0.519200 | 7834.65 | 10551.00 | 0.766484 |
406_408 PTAC COOLING COIL | 0.389400 | 5775.66 | 7913.25 | 0.766484 |
409_412 PTAC COOLING COIL | 0.519200 | 6768.08 | 10551.00 | 0.766484 |
413 PTAC COOLING COIL | 0.129800 | 1751.17 | 2637.75 | 0.766484 |
414 PTAC COOLING COIL | 0.129800 | 1732.55 | 2637.75 | 0.766484 |
415_418 PTAC COOLING COIL | 0.519200 | 6695.76 | 10551.00 | 0.766484 |
419 PTAC COOLING COIL | 0.129800 | 1647.43 | 2637.75 | 0.766484 |
420_423 PTAC COOLING COIL | 0.519200 | 6720.25 | 10551.00 | 0.766484 |
424 PTAC COOLING COIL | 0.129800 | 1639.13 | 2637.75 | 0.766484 |
User-Specified Maximum Flow Rate [m3/s] | |
CORRIDORFLR1 PTAC SUPPLY FAN | 0.130000 |
101 PTAC SUPPLY FAN | 0.130000 |
102 PTAC SUPPLY FAN | 0.130000 |
103 PTAC SUPPLY FAN | 0.130000 |
104 PTAC SUPPLY FAN | 0.130000 |
105 PTAC SUPPLY FAN | 0.130000 |
CORRIDORFLR2 PTAC SUPPLY FAN | 0.130000 |
201 PTAC SUPPLY FAN | 0.130000 |
202_205 PTAC SUPPLY FAN | 0.520000 |
206_208 PTAC SUPPLY FAN | 0.390000 |
209_212 PTAC SUPPLY FAN | 0.520000 |
213 PTAC SUPPLY FAN | 0.130000 |
214 PTAC SUPPLY FAN | 0.130000 |
215_218 PTAC SUPPLY FAN | 0.520000 |
219 PTAC SUPPLY FAN | 0.130000 |
220_223 PTAC SUPPLY FAN | 0.520000 |
224 PTAC SUPPLY FAN | 0.130000 |
CORRIDORFLR3 PTAC SUPPLY FAN | 0.130000 |
301 PTAC SUPPLY FAN | 0.130000 |
302_305 PTAC SUPPLY FAN | 0.520000 |
306_308 PTAC SUPPLY FAN | 0.390000 |
309_312 PTAC SUPPLY FAN | 0.520000 |
313 PTAC SUPPLY FAN | 0.130000 |
314 PTAC SUPPLY FAN | 0.130000 |
315_318 PTAC SUPPLY FAN | 0.520000 |
319 PTAC SUPPLY FAN | 0.130000 |
320_323 PTAC SUPPLY FAN | 0.520000 |
324 PTAC SUPPLY FAN | 0.130000 |
CORRIDORFLR4 PTAC SUPPLY FAN | 0.130000 |
401 PTAC SUPPLY FAN | 0.130000 |
402_405 PTAC SUPPLY FAN | 0.520000 |
406_408 PTAC SUPPLY FAN | 0.390000 |
409_412 PTAC SUPPLY FAN | 0.520000 |
413 PTAC SUPPLY FAN | 0.130000 |
414 PTAC SUPPLY FAN | 0.130000 |
415_418 PTAC SUPPLY FAN | 0.520000 |
419 PTAC SUPPLY FAN | 0.130000 |
420_423 PTAC SUPPLY FAN | 0.520000 |
424 PTAC SUPPLY FAN | 0.130000 |
Design Size Maximum Air Flow Rate [m3/s] | |
FRONTLOUNGEFLR1 DIRECT AIR | 0.977998 |
RESTROOMFLR1 DIRECT AIR | 0.083626 |
MEETINGROOMFLR1 DIRECT AIR | 0.466931 |
EMPLOYEELOUNGEFLR1 DIRECT AIR | 0.878622 |
EXERCISECENTERFLR1 DIRECT AIR | 0.174970 |
FRONTOFFICEFLR1 DIRECT AIR | 0.431895 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
SAC_FRONTOFFICE | 0.431895 | 0.431895 | 0.431895 | 0.431895 | 0.431895 | 0.431895 | 1.00 | 1.00 | 0.431895 |
SAC_FRONTLOUNGE | 0.977998 | 0.977998 | 0.977998 | 0.977998 | 0.977998 | 0.977998 | 1.00 | 1.00 | 0.977998 |
SAC_MEETINGROOM | 0.466931 | 0.466931 | 0.466931 | 0.466931 | 0.466931 | 0.466931 | 1.00 | 1.000000 | 0.466931 |
SAC_EXC_EMPLGE_RESTRM | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.00 | 1.00 | 1.14 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SAC_FRONTOFFICE OA CONTROLLER | 0.431895 | 0.056300 |
SAC_FRONTLOUNGE OA CONTROLLER | 0.977998 | 0.235982 |
SAC_MEETINGROOM OA CONTROLLER | 0.466931 | 0.126367 |
SAC_EXC_EMPLGE_RESTRM OA CONTROLLER | 1.14 | 0.094386 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SAC_FRONTOFFICE | 0.431895 | 0.431895 | 0.431895 | 0.431895 | 8554.06 | 10236.39 | 40.00 | 1.00 |
SAC_FRONTLOUNGE | 0.977998 | 0.977998 | 0.977998 | 0.645478 | 21703.16 | 25636.07 | 40.00 | 1.00 |
SAC_MEETINGROOM | 0.466931 | 0.466931 | 0.466931 | 0.466931 | 11314.36 | 12549.76 | 40.00 | 1.00 |
SAC_EXC_EMPLGE_RESTRM | 1.14 | 1.14 | 1.14 | 0.750564 | 21919.30 | 25733.92 | 40.00 | 0.153858 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
SAC_FRONTOFFICE COOLING COIL | 0.431890 | 0.215945 | 0.287927 | 8203.98 | 8554.06 | 4277.03 | 4277.03 | 0.738279 | 0.738280 | 0.738280 | 0.738280 |
SAC_FRONTLOUNGE COOLING COIL | 0.978000 | 0.489000 | 0.652000 | 20959.78 | 21703.16 | 10851.58 | 10851.58 | 0.705251 | 0.705250 | 0.705250 | 0.705250 |
SAC_MEETINGROOM COOLING COIL | 0.466930 | 0.233465 | 0.311287 | 10975.67 | 11314.36 | 5657.18 | 5657.18 | 0.682162 | 0.682160 | 0.682160 | 0.682160 |
SAC_EXC_EMPLGE_RESTRM COOLING COIL | 1.14 | 0.568610 | 0.758147 | 20997.16 | 21919.30 | 10959.65 | 10959.65 | 0.746755 | 0.746750 | 0.746750 | 0.746750 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
SAC_FO_ADDAQ SUPPLY FAN | 0.431895 | 483.77 |
SAC_FL_ADDAQ SUPPLY FAN | 0.977998 | 1082.80 |
SAC_MR_ADDAQ SUPPLY FAN | 0.466931 | 523.01 |
SAC_EXC_ADDAQ SUPPLY FAN | 1.14 | 1259.08 |
Design Size Nominal Capacity [W] | |
SAC_FRONTOFFICE HEATING COIL | 10236.39 |
SAC_FRONTLOUNGE HEATING COIL | 25636.07 |
SAC_MEETINGROOM HEATING COIL | 12549.76 |
SAC_EXC_EMPLGE_RESTRM HEATING COIL | 25733.92 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYSSHOWER | 0.000180 | 0.021594 |
SHWSYSLAUNDRY | 0.000129 | 0.015520 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | |
SHWSYSSHOWER PUMP | 0.000180 | 8.11 |
SHWSYSLAUNDRY PUMP | 0.000129 | 0.000001 |
Use Side Design Flow Rate [m3/s] | |
SHWSYSSHOWER WATER HEATER | 0.000180 |
SHWSYSLAUNDRY WATER HEATER | 0.000129 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 20:15:15
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesPossible Shadow Receivers | |
ENTRY CANOPY | W_CORRIDORFLR1_16_0_0 | W_FRONTLOUNGEFLR1_4_0_0 | W_FRONTSTAIRSFLR1_4_0_0 | W_CORRIDORFLR2_15_0_0 | W_GUESTROOM201_4_0_0 | W_FRONTSTAIRSFLR2_4_0_0 | W_CORRIDORFLR3_15_0_0 | W_GUESTROOM301_4_0_0 | W_FRONTSTAIRSFLR3_4_0_0 | W_CORRIDORFLR4_15_0_0 | W_GUESTROOM401_4_0_0 | W_FRONTSTAIRSFLR4_4_0_0 | |
Mir-ENTRY CANOPY | W_CORRIDORFLR1_16_0_0 | W_FRONTLOUNGEFLR1_4_0_0 | W_FRONTSTAIRSFLR1_4_0_0 | |
W_CORRIDORFLR1_16_0_0 | Mir-ENTRY CANOPY | |
W_FRONTLOUNGEFLR1_4_0_0 | Mir-ENTRY CANOPY | |
W_FRONTSTAIRSFLR1_4_0_0 | Mir-ENTRY CANOPY | |
Possible Shadow Receivers | |
W_REARSTAIRSFLR1_3_0_0 | W_REARSTAIRSFLR1_3_0_0_DOOR | |
W_CORRIDORFLR1_2_0_0 | W_CORRIDORFLR1_2_0_0_0_0 | |
W_CORRIDORFLR1_10_0_0 | W_CORRIDORFLR1_10_0_0_DOOR | |
W_CORRIDORFLR1_16_0_0 | D_CORRIDORFLR1_16_0_0_0_0 | |
W_CORRIDORFLR1_20_0_0 | W_CORRIDORFLR1_20_0_0_0_0 | |
W_FRONTLOUNGEFLR1_5_0_0 | W_FRONTLOUNGEFLR1_5_0_0_0_0 | W_FRONTLOUNGEFLR1_5_0_0_0_1 | W_FRONTLOUNGEFLR1_5_0_0_0_2 | W_FRONTLOUNGEFLR1_5_0_0_0_3 | W_FRONTLOUNGEFLR1_5_0_0_0_4 | |
W_MEETINGROOMFLR1_5_0_0 | W_MEETINGROOMFLR1_5_0_0_0_0 | W_MEETINGROOMFLR1_5_0_0_0_1 | W_MEETINGROOMFLR1_5_0_0_0_2 | |
W_GUESTROOM101_5_0_0 | W_GUESTROOM101_5_0_0_0_0 | |
W_GUESTROOM102_5_0_0 | W_GUESTROOM102_5_0_0_0_0 | |
W_GUESTROOM103_5_0_0 | W_GUESTROOM103_5_0_0_0_0 | |
W_GUESTROOM104_3_0_0 | W_GUESTROOM104_3_0_0_0_0 | |
W_GUESTROOM105_3_0_0 | W_GUESTROOM105_3_0_0_0_0 | |
W_EMPLOYEELOUNGEFLR1_3_0_0 | W_EMPLOYEELOUNGEFLR1_3_0_0_0_0 | |
W_LAUNDRYROOMFLR1_3_0_0 | W_LAUNDRYROOMFLR1_3_0_0_0_0 | W_LAUNDRYROOMFLR1_3_0_0_0_1 | W_LAUNDRYROOMFLR1_3_0_0_0_2 | |
W_EXERCISECENTERFLR1_3_0_0 | W_EXERCISECENTERFLR1_3_0_0_0_0 | |
W_FRONTOFFICEFLR1_3_0_0 | W_FRONTOFFICEFLR1_3_0_0_0_0 | W_FRONTOFFICEFLR1_3_0_0_0_1 | W_FRONTOFFICEFLR1_3_0_0_0_2 | W_FRONTOFFICEFLR1_3_0_0_0_3 | |
W_FRONTSTAIRSFLR1_3_0_0 | W_FRONTSTAIRSFLR1_3_0_0_DOOR | |
W_CORRIDORFLR2_2_0_0 | W_CORRIDORFLR2_2_0_0_0_0 | |
W_CORRIDORFLR2_15_0_0 | W_CORRIDORFLR2_15_0_0_0_0 | |
W_GUESTROOM201_5_0_0 | W_GUESTROOM201_5_0_0_0_0 | |
W_GUESTROOM202_205_5_0_0 | W_GUESTROOM202_205_5_0_0_0_0 | W_GUESTROOM202_205_5_0_0_0_1 | W_GUESTROOM202_205_5_0_0_0_2 | W_GUESTROOM202_205_5_0_0_0_3 | |
W_GUESTROOM206_208_5_0_0 | W_GUESTROOM206_208_5_0_0_0_0 | W_GUESTROOM206_208_5_0_0_0_1 | W_GUESTROOM206_208_5_0_0_0_2 | |
W_GUESTROOM209_212_5_0_0 | W_GUESTROOM209_212_5_0_0_0_0 | W_GUESTROOM209_212_5_0_0_0_1 | W_GUESTROOM209_212_5_0_0_0_2 | W_GUESTROOM209_212_5_0_0_0_3 | |
W_GUESTROOM213_5_0_0 | W_GUESTROOM213_5_0_0_0_0 | |
W_GUESTROOM214_3_0_0 | W_GUESTROOM214_3_0_0_0_0 | |
W_GUESTROOM215_218_3_0_0 | W_GUESTROOM215_218_3_0_0_0_0 | W_GUESTROOM215_218_3_0_0_0_1 | W_GUESTROOM215_218_3_0_0_0_2 | W_GUESTROOM215_218_3_0_0_0_3 | |
W_GUESTROOM219_3_0_0 | W_GUESTROOM219_3_0_0_0_0 | |
W_GUESTROOM220_223_3_0_0 | W_GUESTROOM220_223_3_0_0_0_0 | W_GUESTROOM220_223_3_0_0_0_1 | W_GUESTROOM220_223_3_0_0_0_2 | W_GUESTROOM220_223_3_0_0_0_3 | |
W_GUESTROOM224_3_0_0 | W_GUESTROOM224_3_0_0_0_0 | |
W_CORRIDORFLR3_2_0_0 | W_CORRIDORFLR3_2_0_0_0_0 | |
W_CORRIDORFLR3_15_0_0 | W_CORRIDORFLR3_15_0_0_0_0 | |
W_GUESTROOM301_5_0_0 | W_GUESTROOM301_5_0_0_0_0 | |
W_GUESTROOM302_305_5_0_0 | W_GUESTROOM302_305_5_0_0_0_0 | W_GUESTROOM302_305_5_0_0_0_1 | W_GUESTROOM302_305_5_0_0_0_2 | W_GUESTROOM302_305_5_0_0_0_3 | |
W_GUESTROOM306_308_5_0_0 | W_GUESTROOM306_308_5_0_0_0_0 | W_GUESTROOM306_308_5_0_0_0_1 | W_GUESTROOM306_308_5_0_0_0_2 | |
W_GUESTROOM309_312_5_0_0 | W_GUESTROOM309_312_5_0_0_0_0 | W_GUESTROOM309_312_5_0_0_0_1 | W_GUESTROOM309_312_5_0_0_0_2 | W_GUESTROOM309_312_5_0_0_0_3 | |
W_GUESTROOM313_5_0_0 | W_GUESTROOM313_5_0_0_0_0 | |
W_GUESTROOM314_3_0_0 | W_GUESTROOM314_3_0_0_0_0 | |
W_GUESTROOM315_318_3_0_0 | W_GUESTROOM315_318_3_0_0_0_0 | W_GUESTROOM315_318_3_0_0_0_1 | W_GUESTROOM315_318_3_0_0_0_2 | W_GUESTROOM315_318_3_0_0_0_3 | |
W_GUESTROOM319_3_0_0 | W_GUESTROOM319_3_0_0_0_0 | |
W_GUESTROOM320_323_3_0_0 | W_GUESTROOM320_323_3_0_0_0_0 | W_GUESTROOM320_323_3_0_0_0_1 | W_GUESTROOM320_323_3_0_0_0_2 | W_GUESTROOM320_323_3_0_0_0_3 | |
W_GUESTROOM324_3_0_0 | W_GUESTROOM324_3_0_0_0_0 | |
W_CORRIDORFLR4_2_0_0 | W_CORRIDORFLR4_2_0_0_0_0 | |
W_CORRIDORFLR4_15_0_0 | W_CORRIDORFLR4_15_0_0_0_0 | |
W_GUESTROOM401_5_0_0 | W_GUESTROOM401_5_0_0_0_0 | |
W_GUESTROOM402_405_5_0_0 | W_GUESTROOM402_405_5_0_0_0_0 | W_GUESTROOM402_405_5_0_0_0_1 | W_GUESTROOM402_405_5_0_0_0_2 | W_GUESTROOM402_405_5_0_0_0_3 | |
W_GUESTROOM406_408_5_0_0 | W_GUESTROOM406_408_5_0_0_0_0 | W_GUESTROOM406_408_5_0_0_0_1 | W_GUESTROOM406_408_5_0_0_0_2 | |
W_GUESTROOM409_412_5_0_0 | W_GUESTROOM409_412_5_0_0_0_0 | W_GUESTROOM409_412_5_0_0_0_1 | W_GUESTROOM409_412_5_0_0_0_2 | W_GUESTROOM409_412_5_0_0_0_3 | |
W_GUESTROOM413_5_0_0 | W_GUESTROOM413_5_0_0_0_0 | |
W_GUESTROOM414_3_0_0 | W_GUESTROOM414_3_0_0_0_0 | |
W_GUESTROOM415_418_3_0_0 | W_GUESTROOM415_418_3_0_0_0_0 | W_GUESTROOM415_418_3_0_0_0_1 | W_GUESTROOM415_418_3_0_0_0_2 | W_GUESTROOM415_418_3_0_0_0_3 | |
W_GUESTROOM419_3_0_0 | W_GUESTROOM419_3_0_0_0_0 | |
W_GUESTROOM420_423_3_0_0 | W_GUESTROOM420_423_3_0_0_0_0 | W_GUESTROOM420_423_3_0_0_0_1 | W_GUESTROOM420_423_3_0_0_0_2 | W_GUESTROOM420_423_3_0_0_0_3 | |
W_GUESTROOM424_3_0_0 | W_GUESTROOM424_3_0_0_0_0 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 20:15:15
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 20:15:15
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 20.90 | 15.40 | 11.90 | 14.80 | 12.70 | 15.40 | 23.30 | 26.30 | 31.20 | 30.40 | 29.80 | 27.80 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745 | 32.17 | -110.88 | -7.00 | 809.00 | 91976 | 1.0932 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 21.66 | 19.30 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | HotelSmall | 180.000 | Suburbs | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.220 | 370.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | LowerLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 2 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 67 | 591 | 106 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | REARSTAIRSFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -53.69 | -14.22 | 1.68 | 1 | 1 | 1 | -54.91 | -52.47 | -18.34 | -10.11 | 0.00 | 3.35 | 3.35 | 67.30 | TARP | TARP | 20.07 | 35.77 | 33.82 | 0.00 | 6 | 1 | 0 | Yes |
2 | CORRIDORFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -26.68 | -9.43 | 1.68 | 1 | 1 | 1 | -54.91 | -4.87E-002 | -18.34 | -4.88E-002 | 0.00 | 3.35 | 3.35 | 504.62 | TARP | TARP | 150.51 | 32.70 | 20.94 | 9.82 | 29 | 4 | 2 | Yes |
3 | REARSTORAGEFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -53.69 | -4.16 | 1.68 | 1 | 1 | 1 | -54.91 | -52.47 | -8.28 | -4.88E-002 | 0.00 | 3.35 | 3.35 | 67.30 | TARP | TARP | 20.07 | 35.77 | 35.77 | 0.00 | 6 | 0 | 0 | Yes |
4 | FRONTLOUNGEFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -9.95 | -4.16 | 1.68 | 1 | 1 | 1 | -19.86 | -4.87E-002 | -8.28 | -4.88E-002 | 0.00 | 3.35 | 3.35 | 546.70 | TARP | TARP | 163.06 | 94.02 | 79.19 | 14.83 | 7 | 5 | 0 | Yes |
5 | RESTROOMFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -21.84 | -4.16 | 1.68 | 1 | 1 | 1 | -23.82 | -19.86 | -8.28 | -4.88E-002 | 0.00 | 3.35 | 3.35 | 109.34 | TARP | TARP | 32.61 | 13.29 | 13.29 | 0.00 | 6 | 0 | 0 | Yes |
6 | MEETINGROOMFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -31.75 | -4.16 | 1.68 | 1 | 1 | 1 | -36.62 | -26.87 | -8.28 | -4.88E-002 | 0.00 | 3.35 | 3.35 | 269.14 | TARP | TARP | 80.27 | 32.70 | 27.77 | 4.94 | 7 | 3 | 0 | Yes |
7 | MECHANICALROOMFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -38.61 | -4.16 | 1.68 | 1 | 1 | 1 | -40.59 | -36.62 | -8.28 | -4.88E-002 | 0.00 | 3.35 | 3.35 | 109.34 | TARP | TARP | 32.61 | 13.29 | 13.29 | 0.00 | 6 | 0 | 0 | Yes |
8 | GUESTROOM101 | 0.0 | 0.00 | 0.00 | 0.00 | -42.57 | -4.16 | 1.68 | 1 | 1 | 1 | -44.55 | -40.59 | -8.28 | -4.88E-002 | 0.00 | 3.35 | 3.35 | 109.34 | TARP | TARP | 32.61 | 13.29 | 11.64 | 1.65 | 6 | 1 | 0 | Yes |
9 | GUESTROOM102 | 0.0 | 0.00 | 0.00 | 0.00 | -46.53 | -4.16 | 1.68 | 1 | 1 | 1 | -48.51 | -44.55 | -8.28 | -4.88E-002 | 0.00 | 3.35 | 3.35 | 109.34 | TARP | TARP | 32.61 | 13.29 | 11.64 | 1.65 | 6 | 1 | 0 | Yes |
10 | GUESTROOM103 | 0.0 | 0.00 | 0.00 | 0.00 | -50.49 | -4.16 | 1.68 | 1 | 1 | 1 | -52.47 | -48.51 | -8.28 | -4.88E-002 | 0.00 | 3.35 | 3.35 | 109.34 | TARP | TARP | 32.61 | 13.29 | 11.64 | 1.65 | 6 | 1 | 0 | Yes |
11 | GUESTROOM104 | 0.0 | 0.00 | 0.00 | 0.00 | -50.49 | -14.22 | 1.68 | 1 | 1 | 1 | -52.47 | -48.51 | -18.34 | -10.11 | 0.00 | 3.35 | 3.35 | 109.33 | TARP | TARP | 32.61 | 13.29 | 11.64 | 1.65 | 6 | 1 | 0 | Yes |
12 | GUESTROOM105 | 0.0 | 0.00 | 0.00 | 0.00 | -46.53 | -14.22 | 1.68 | 1 | 1 | 1 | -48.51 | -44.55 | -18.34 | -10.11 | 0.00 | 3.35 | 3.35 | 109.33 | TARP | TARP | 32.61 | 13.29 | 11.64 | 1.65 | 6 | 1 | 0 | Yes |
13 | EMPLOYEELOUNGEFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -42.57 | -14.22 | 1.68 | 1 | 1 | 1 | -44.55 | -40.59 | -18.34 | -10.11 | 0.00 | 3.35 | 3.35 | 109.33 | TARP | TARP | 32.61 | 13.29 | 11.64 | 1.65 | 6 | 1 | 0 | Yes |
14 | LAUNDRYROOMFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -34.64 | -14.22 | 1.68 | 1 | 1 | 1 | -40.59 | -28.70 | -18.34 | -10.11 | 0.00 | 3.35 | 3.35 | 327.99 | TARP | TARP | 97.83 | 39.86 | 34.92 | 4.94 | 7 | 3 | 0 | Yes |
15 | ELEVATORCOREFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -27.79 | -14.22 | 1.68 | 1 | 1 | 1 | -28.70 | -26.87 | -18.34 | -10.11 | 0.00 | 3.35 | 3.35 | 50.46 | TARP | TARP | 15.05 | 6.13 | 6.13 | 0.00 | 6 | 0 | 0 | Yes |
16 | EXERCISECENTERFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -21.84 | -14.22 | 1.68 | 1 | 1 | 1 | -23.82 | -19.86 | -18.34 | -10.11 | 0.00 | 3.35 | 3.35 | 109.33 | TARP | TARP | 32.61 | 13.29 | 11.64 | 1.65 | 6 | 1 | 0 | Yes |
17 | FRONTOFFICEFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -11.94 | -14.22 | 1.68 | 1 | 1 | 1 | -19.86 | -4.01 | -18.34 | -10.11 | 0.00 | 3.35 | 3.35 | 437.33 | TARP | TARP | 130.44 | 53.14 | 46.56 | 6.58 | 7 | 4 | 0 | Yes |
18 | FRONTSTAIRSFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -1.27 | -14.22 | 1.68 | 1 | 1 | 1 | -2.49 | -4.87E-002 | -18.34 | -10.11 | 0.00 | 3.35 | 3.35 | 67.28 | TARP | TARP | 20.07 | 35.77 | 33.82 | 0.00 | 6 | 1 | 0 | Yes |
19 | FRONTSTORAGEFLR1 | 0.0 | 0.00 | 0.00 | 0.00 | -3.25 | -14.22 | 1.68 | 1 | 1 | 1 | -4.01 | -2.49 | -18.34 | -10.11 | 0.00 | 3.35 | 3.35 | 42.05 | TARP | TARP | 12.54 | 5.11 | 5.11 | 0.00 | 6 | 0 | 0 | Yes |
20 | REARSTAIRSFLR2 | 0.0 | 0.00 | 0.00 | 0.00 | -53.69 | -14.22 | 4.72 | 1 | 1 | 1 | -54.91 | -52.47 | -18.34 | -10.11 | 3.35 | 6.10 | 2.74 | 55.06 | TARP | TARP | 20.07 | 29.27 | 29.27 | 0.00 | 6 | 0 | 0 | Yes |
21 | CORRIDORFLR2 | 0.0 | 0.00 | 0.00 | 0.00 | -26.88 | -10.72 | 4.72 | 1 | 1 | 1 | -54.91 | -4.87E-002 | -18.34 | -8.28 | 3.35 | 6.10 | 2.74 | 344.05 | TARP | TARP | 125.42 | 18.39 | 15.77 | 2.62 | 22 | 2 | 0 | Yes |
22 | REARSTORAGEFLR2 | 0.0 | 0.00 | 0.00 | 0.00 | -53.69 | -4.16 | 4.72 | 1 | 1 | 1 | -54.91 | -52.47 | -8.28 | -4.88E-002 | 3.35 | 6.10 | 2.74 | 55.07 | TARP | TARP | 20.07 | 29.27 | 29.27 | 0.00 | 6 | 0 | 0 | Yes |
23 | GUESTROOM201 | 0.0 | 0.00 | 0.00 | 0.00 | -2.03 | -4.16 | 4.72 | 1 | 1 | 1 | -4.01 | -4.87E-002 | -8.28 | -4.88E-002 | 3.35 | 6.10 | 2.74 | 89.46 | TARP | TARP | 32.61 | 33.45 | 31.80 | 1.65 | 6 | 1 | 0 | Yes |
24 | GUESTROOM202_205 | 0.0 | 0.00 | 0.00 | 0.00 | -11.94 | -4.16 | 4.72 | 1 | 1 | 1 | -19.86 | -4.01 | -8.28 | -4.88E-002 | 3.35 | 6.10 | 2.74 | 357.84 | TARP | TARP | 130.45 | 43.48 | 36.90 | 6.58 | 6 | 4 | 0 | Yes |
25 | GUESTROOM206_208 | 0.0 | 0.00 | 0.00 | 0.00 | -26.26 | -4.16 | 4.72 | 1 | 1 | 1 | -32.66 | -19.86 | -8.28 | -4.88E-002 | 3.35 | 6.10 | 2.74 | 289.02 | TARP | TARP | 105.36 | 35.12 | 28.42 | 6.70 | 8 | 3 | 0 | Yes |
26 | GUESTROOM209_212 | 0.0 | 0.00 | 0.00 | 0.00 | -40.59 | -4.16 | 4.72 | 1 | 1 | 1 | -48.51 | -32.66 | -8.28 | -4.88E-002 | 3.35 | 6.10 | 2.74 | 357.84 | TARP | TARP | 130.45 | 43.48 | 36.90 | 6.58 | 9 | 4 | 0 | Yes |
27 | GUESTROOM213 | 0.0 | 0.00 | 0.00 | 0.00 | -50.49 | -4.16 | 4.72 | 1 | 1 | 1 | -52.47 | -48.51 | -8.28 | -4.88E-002 | 3.35 | 6.10 | 2.74 | 89.46 | TARP | TARP | 32.61 | 10.87 | 9.22 | 1.65 | 6 | 1 | 0 | Yes |
28 | GUESTROOM214 | 0.0 | 0.00 | 0.00 | 0.00 | -50.49 | -14.22 | 4.72 | 1 | 1 | 1 | -52.47 | -48.51 | -18.34 | -10.11 | 3.35 | 6.10 | 2.74 | 89.45 | TARP | TARP | 32.61 | 10.87 | 9.22 | 1.65 | 6 | 1 | 0 | Yes |
29 | GUESTROOM215_218 | 0.0 | 0.00 | 0.00 | 0.00 | -40.59 | -14.22 | 4.72 | 1 | 1 | 1 | -48.51 | -32.66 | -18.34 | -10.11 | 3.35 | 6.10 | 2.74 | 357.81 | TARP | TARP | 130.44 | 43.48 | 36.90 | 6.58 | 8 | 4 | 0 | Yes |
30 | ELEVATORCOREFLR2 | 0.0 | 0.00 | 0.00 | 0.00 | -27.79 | -14.22 | 4.72 | 1 | 1 | 1 | -28.70 | -26.87 | -18.34 | -10.11 | 3.35 | 6.10 | 2.74 | 41.29 | TARP | TARP | 15.05 | 5.02 | 5.02 | 0.00 | 6 | 0 | 0 | Yes |
31 | GUESTROOM219 | 0.0 | 0.00 | 0.00 | 0.00 | -30.68 | -14.22 | 4.72 | 1 | 1 | 1 | -32.66 | -28.70 | -18.34 | -10.11 | 3.35 | 6.10 | 2.74 | 89.45 | TARP | TARP | 32.61 | 10.87 | 9.22 | 1.65 | 6 | 1 | 0 | Yes |
32 | GUESTROOM220_223 | 0.0 | 0.00 | 0.00 | 0.00 | -15.90 | -14.22 | 4.72 | 1 | 1 | 1 | -23.82 | -7.97 | -18.34 | -10.11 | 3.35 | 6.10 | 2.74 | 357.81 | TARP | TARP | 130.44 | 43.48 | 36.90 | 6.58 | 7 | 4 | 0 | Yes |
33 | GUESTROOM224 | 0.0 | 0.00 | 0.00 | 0.00 | -5.99 | -14.22 | 4.72 | 1 | 1 | 1 | -7.97 | -4.01 | -18.34 | -10.11 | 3.35 | 6.10 | 2.74 | 89.45 | TARP | TARP | 32.61 | 10.87 | 9.22 | 1.65 | 6 | 1 | 0 | Yes |
34 | FRONTSTORAGEFLR2 | 0.0 | 0.00 | 0.00 | 0.00 | -3.25 | -14.22 | 4.72 | 1 | 1 | 1 | -4.01 | -2.49 | -18.34 | -10.11 | 3.35 | 6.10 | 2.74 | 34.40 | TARP | TARP | 12.54 | 4.18 | 4.18 | 0.00 | 6 | 0 | 0 | Yes |
35 | FRONTSTAIRSFLR2 | 0.0 | 0.00 | 0.00 | 0.00 | -1.27 | -14.22 | 4.72 | 1 | 1 | 1 | -2.49 | -4.87E-002 | -18.34 | -10.11 | 3.35 | 6.10 | 2.74 | 55.05 | TARP | TARP | 20.07 | 29.26 | 29.26 | 0.00 | 6 | 0 | 0 | Yes |
36 | REARSTAIRSFLR3 | 0.0 | 0.00 | 0.00 | 0.00 | -53.69 | -14.22 | 7.47 | 1 | 1 | 1 | -54.91 | -52.47 | -18.34 | -10.11 | 6.10 | 8.84 | 2.74 | 55.06 | TARP | TARP | 20.07 | 29.27 | 29.27 | 0.00 | 6 | 0 | 0 | Yes |
37 | CORRIDORFLR3 | 0.0 | 0.00 | 0.00 | 0.00 | -26.88 | -10.72 | 7.47 | 1 | 1 | 1 | -54.91 | -4.87E-002 | -18.34 | -8.28 | 6.10 | 8.84 | 2.74 | 344.05 | TARP | TARP | 125.42 | 18.39 | 15.77 | 2.62 | 22 | 2 | 0 | Yes |
38 | REARSTORAGEFLR3 | 0.0 | 0.00 | 0.00 | 0.00 | -53.69 | -4.16 | 7.47 | 1 | 1 | 1 | -54.91 | -52.47 | -8.28 | -4.88E-002 | 6.10 | 8.84 | 2.74 | 55.07 | TARP | TARP | 20.07 | 29.27 | 29.27 | 0.00 | 6 | 0 | 0 | Yes |
39 | GUESTROOM301 | 0.0 | 0.00 | 0.00 | 0.00 | -2.03 | -4.16 | 7.47 | 1 | 1 | 1 | -4.01 | -4.87E-002 | -8.28 | -4.88E-002 | 6.10 | 8.84 | 2.74 | 89.46 | TARP | TARP | 32.61 | 33.45 | 31.80 | 1.65 | 6 | 1 | 0 | Yes |
40 | GUESTROOM302_305 | 0.0 | 0.00 | 0.00 | 0.00 | -11.94 | -4.16 | 7.47 | 1 | 1 | 1 | -19.86 | -4.01 | -8.28 | -4.88E-002 | 6.10 | 8.84 | 2.74 | 357.84 | TARP | TARP | 130.45 | 43.48 | 36.90 | 6.58 | 6 | 4 | 0 | Yes |
41 | GUESTROOM306_308 | 0.0 | 0.00 | 0.00 | 0.00 | -26.26 | -4.16 | 7.47 | 1 | 1 | 1 | -32.66 | -19.86 | -8.28 | -4.88E-002 | 6.10 | 8.84 | 2.74 | 289.02 | TARP | TARP | 105.36 | 35.12 | 28.42 | 6.70 | 6 | 3 | 0 | Yes |
42 | GUESTROOM309_312 | 0.0 | 0.00 | 0.00 | 0.00 | -40.59 | -4.16 | 7.47 | 1 | 1 | 1 | -48.51 | -32.66 | -8.28 | -4.88E-002 | 6.10 | 8.84 | 2.74 | 357.84 | TARP | TARP | 130.45 | 43.48 | 36.90 | 6.58 | 6 | 4 | 0 | Yes |
43 | GUESTROOM313 | 0.0 | 0.00 | 0.00 | 0.00 | -50.49 | -4.16 | 7.47 | 1 | 1 | 1 | -52.47 | -48.51 | -8.28 | -4.88E-002 | 6.10 | 8.84 | 2.74 | 89.46 | TARP | TARP | 32.61 | 10.87 | 9.22 | 1.65 | 6 | 1 | 0 | Yes |
44 | GUESTROOM314 | 0.0 | 0.00 | 0.00 | 0.00 | -50.49 | -14.22 | 7.47 | 1 | 1 | 1 | -52.47 | -48.51 | -18.34 | -10.11 | 6.10 | 8.84 | 2.74 | 89.45 | TARP | TARP | 32.61 | 10.87 | 9.22 | 1.65 | 6 | 1 | 0 | Yes |
45 | GUESTROOM315_318 | 0.0 | 0.00 | 0.00 | 0.00 | -40.59 | -14.22 | 7.47 | 1 | 1 | 1 | -48.51 | -32.66 | -18.34 | -10.11 | 6.10 | 8.84 | 2.74 | 357.81 | TARP | TARP | 130.44 | 43.48 | 36.90 | 6.58 | 6 | 4 | 0 | Yes |
46 | ELEVATORCOREFLR3 | 0.0 | 0.00 | 0.00 | 0.00 | -27.79 | -14.22 | 7.47 | 1 | 1 | 1 | -28.70 | -26.87 | -18.34 | -10.11 | 6.10 | 8.84 | 2.74 | 41.29 | TARP | TARP | 15.05 | 5.02 | 5.02 | 0.00 | 6 | 0 | 0 | Yes |
47 | GUESTROOM319 | 0.0 | 0.00 | 0.00 | 0.00 | -30.68 | -14.22 | 7.47 | 1 | 1 | 1 | -32.66 | -28.70 | -18.34 | -10.11 | 6.10 | 8.84 | 2.74 | 89.45 | TARP | TARP | 32.61 | 10.87 | 9.22 | 1.65 | 6 | 1 | 0 | Yes |
48 | GUESTROOM320_323 | 0.0 | 0.00 | 0.00 | 0.00 | -15.90 | -14.22 | 7.47 | 1 | 1 | 1 | -23.82 | -7.97 | -18.34 | -10.11 | 6.10 | 8.84 | 2.74 | 357.81 | TARP | TARP | 130.44 | 43.48 | 36.90 | 6.58 | 6 | 4 | 0 | Yes |
49 | GUESTROOM324 | 0.0 | 0.00 | 0.00 | 0.00 | -5.99 | -14.22 | 7.47 | 1 | 1 | 1 | -7.97 | -4.01 | -18.34 | -10.11 | 6.10 | 8.84 | 2.74 | 89.45 | TARP | TARP | 32.61 | 10.87 | 9.22 | 1.65 | 6 | 1 | 0 | Yes |
50 | FRONTSTORAGEFLR3 | 0.0 | 0.00 | 0.00 | 0.00 | -3.25 | -14.22 | 7.47 | 1 | 1 | 1 | -4.01 | -2.49 | -18.34 | -10.11 | 6.10 | 8.84 | 2.74 | 34.40 | TARP | TARP | 12.54 | 4.18 | 4.18 | 0.00 | 6 | 0 | 0 | Yes |
51 | FRONTSTAIRSFLR3 | 0.0 | 0.00 | 0.00 | 0.00 | -1.27 | -14.22 | 7.47 | 1 | 1 | 1 | -2.49 | -4.87E-002 | -18.34 | -10.11 | 6.10 | 8.84 | 2.74 | 55.05 | TARP | TARP | 20.07 | 29.26 | 29.26 | 0.00 | 6 | 0 | 0 | Yes |
52 | REARSTAIRSFLR4 | 0.0 | 0.00 | 0.00 | 0.00 | -53.69 | -14.22 | 10.21 | 1 | 1 | 1 | -54.91 | -52.47 | -18.34 | -10.11 | 8.84 | 11.58 | 2.74 | 55.06 | TARP | TARP | 20.07 | 29.27 | 29.27 | 0.00 | 6 | 0 | 0 | Yes |
53 | CORRIDORFLR4 | 0.0 | 0.00 | 0.00 | 0.00 | -26.88 | -10.72 | 10.21 | 1 | 1 | 1 | -54.91 | -4.87E-002 | -18.34 | -8.28 | 8.84 | 11.58 | 2.74 | 344.05 | TARP | TARP | 125.42 | 18.39 | 15.77 | 2.62 | 22 | 2 | 0 | Yes |
54 | REARSTORAGEFLR4 | 0.0 | 0.00 | 0.00 | 0.00 | -53.69 | -4.16 | 10.21 | 1 | 1 | 1 | -54.91 | -52.47 | -8.28 | -4.88E-002 | 8.84 | 11.58 | 2.74 | 55.07 | TARP | TARP | 20.07 | 29.27 | 29.27 | 0.00 | 6 | 0 | 0 | Yes |
55 | GUESTROOM401 | 0.0 | 0.00 | 0.00 | 0.00 | -2.03 | -4.16 | 10.21 | 1 | 1 | 1 | -4.01 | -4.87E-002 | -8.28 | -4.88E-002 | 8.84 | 11.58 | 2.74 | 89.46 | TARP | TARP | 32.61 | 33.45 | 31.80 | 1.65 | 6 | 1 | 0 | Yes |
56 | GUESTROOM402_405 | 0.0 | 0.00 | 0.00 | 0.00 | -11.94 | -4.16 | 10.21 | 1 | 1 | 1 | -19.86 | -4.01 | -8.28 | -4.88E-002 | 8.84 | 11.58 | 2.74 | 357.84 | TARP | TARP | 130.45 | 43.48 | 36.90 | 6.58 | 6 | 4 | 0 | Yes |
57 | GUESTROOM406_408 | 0.0 | 0.00 | 0.00 | 0.00 | -26.26 | -4.16 | 10.21 | 1 | 1 | 1 | -32.66 | -19.86 | -8.28 | -4.88E-002 | 8.84 | 11.58 | 2.74 | 289.02 | TARP | TARP | 105.36 | 35.12 | 28.42 | 6.70 | 6 | 3 | 0 | Yes |
58 | GUESTROOM409_412 | 0.0 | 0.00 | 0.00 | 0.00 | -40.59 | -4.16 | 10.21 | 1 | 1 | 1 | -48.51 | -32.66 | -8.28 | -4.88E-002 | 8.84 | 11.58 | 2.74 | 357.84 | TARP | TARP | 130.45 | 43.48 | 36.90 | 6.58 | 6 | 4 | 0 | Yes |
59 | GUESTROOM413 | 0.0 | 0.00 | 0.00 | 0.00 | -50.49 | -4.16 | 10.21 | 1 | 1 | 1 | -52.47 | -48.51 | -8.28 | -4.88E-002 | 8.84 | 11.58 | 2.74 | 89.46 | TARP | TARP | 32.61 | 10.87 | 9.22 | 1.65 | 6 | 1 | 0 | Yes |
60 | GUESTROOM414 | 0.0 | 0.00 | 0.00 | 0.00 | -50.49 | -14.22 | 10.21 | 1 | 1 | 1 | -52.47 | -48.51 | -18.34 | -10.11 | 8.84 | 11.58 | 2.74 | 89.45 | TARP | TARP | 32.61 | 10.87 | 9.22 | 1.65 | 6 | 1 | 0 | Yes |
61 | GUESTROOM415_418 | 0.0 | 0.00 | 0.00 | 0.00 | -40.59 | -14.22 | 10.21 | 1 | 1 | 1 | -48.51 | -32.66 | -18.34 | -10.11 | 8.84 | 11.58 | 2.74 | 357.81 | TARP | TARP | 130.44 | 43.48 | 36.90 | 6.58 | 6 | 4 | 0 | Yes |
62 | ELEVATORCOREFLR4 | 0.0 | 0.00 | 0.00 | 0.00 | -27.79 | -14.22 | 10.21 | 1 | 1 | 1 | -28.70 | -26.87 | -18.34 | -10.11 | 8.84 | 11.58 | 2.74 | 41.29 | TARP | TARP | 15.05 | 5.02 | 5.02 | 0.00 | 6 | 0 | 0 | Yes |
63 | GUESTROOM419 | 0.0 | 0.00 | 0.00 | 0.00 | -30.68 | -14.22 | 10.21 | 1 | 1 | 1 | -32.66 | -28.70 | -18.34 | -10.11 | 8.84 | 11.58 | 2.74 | 89.45 | TARP | TARP | 32.61 | 10.87 | 9.22 | 1.65 | 6 | 1 | 0 | Yes |
64 | GUESTROOM420_423 | 0.0 | 0.00 | 0.00 | 0.00 | -15.90 | -14.22 | 10.21 | 1 | 1 | 1 | -23.82 | -7.97 | -18.34 | -10.11 | 8.84 | 11.58 | 2.74 | 357.81 | TARP | TARP | 130.44 | 43.48 | 36.90 | 6.58 | 6 | 4 | 0 | Yes |
65 | GUESTROOM424 | 0.0 | 0.00 | 0.00 | 0.00 | -5.99 | -14.22 | 10.21 | 1 | 1 | 1 | -7.97 | -4.01 | -18.34 | -10.11 | 8.84 | 11.58 | 2.74 | 89.45 | TARP | TARP | 32.61 | 10.87 | 9.22 | 1.65 | 6 | 1 | 0 | Yes |
66 | FRONTSTORAGEFLR4 | 0.0 | 0.00 | 0.00 | 0.00 | -3.25 | -14.22 | 10.21 | 1 | 1 | 1 | -4.01 | -2.49 | -18.34 | -10.11 | 8.84 | 11.58 | 2.74 | 34.40 | TARP | TARP | 12.54 | 4.18 | 4.18 | 0.00 | 6 | 0 | 0 | Yes |
67 | FRONTSTAIRSFLR4 | 0.0 | 0.00 | 0.00 | 0.00 | -1.27 | -14.22 | 10.21 | 1 | 1 | 1 | -2.49 | -4.87E-002 | -18.34 | -10.11 | 8.84 | 11.58 | 2.74 | 55.05 | TARP | TARP | 20.07 | 29.26 | 29.26 | 0.00 | 6 | 0 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | REARSTAIRSFLR1 | 20.07 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
2 | CORRIDORFLR1 | 150.51 | 0.0 | N/A | 0.000 | 5.296 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.296 | No |
3 | REARSTORAGEFLR1 | 20.07 | 0.0 | N/A | 0.000 | 4.090 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.090 | No |
4 | FRONTLOUNGEFLR1 | 163.06 | 53.0 | 3.077 | 0.325 | 5.490 | 26.060 | 0.000 | 0.000 | 0.000 | 0.000 | 31.550 | No |
5 | RESTROOMFLR1 | 32.61 | 1.0 | 32.611 | 3.066E-002 | 6.781 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.781 | No |
6 | MEETINGROOMFLR1 | 80.27 | 43.0 | 1.867 | 0.536 | 10.441 | 6.180 | 0.000 | 0.000 | 0.000 | 0.000 | 16.621 | No |
7 | MECHANICALROOMFLR1 | 32.61 | 0.0 | N/A | 0.000 | 10.226 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 10.226 | No |
8 | GUESTROOM101 | 32.61 | 1.5 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
9 | GUESTROOM102 | 32.61 | 1.5 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
10 | GUESTROOM103 | 32.61 | 1.5 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
11 | GUESTROOM104 | 32.61 | 1.5 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
12 | GUESTROOM105 | 32.61 | 1.5 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
13 | EMPLOYEELOUNGEFLR1 | 32.61 | 18.0 | 1.812 | 0.552 | 4.521 | 21.510 | 0.000 | 0.000 | 0.000 | 0.000 | 26.031 | No |
14 | LAUNDRYROOMFLR1 | 97.83 | 11.0 | 8.893 | 0.112 | 5.705 | 27.693 | 409.867 | 0.000 | 0.000 | 0.000 | 443.265 | No |
15 | ELEVATORCOREFLR1 | 15.05 | 0.0 | N/A | 0.000 | 0.000 | 2141.812 | 0.000 | 0.000 | 0.000 | 0.000 | 2141.812 | No |
16 | EXERCISECENTERFLR1 | 32.61 | 7.0 | 4.658 | 0.215 | 11.625 | 18.590 | 0.000 | 0.000 | 0.000 | 0.000 | 30.215 | No |
17 | FRONTOFFICEFLR1 | 130.44 | 10.0 | 13.044 | 7.667E-002 | 7.965 | 13.780 | 0.000 | 0.000 | 0.000 | 0.000 | 21.745 | No |
18 | FRONTSTAIRSFLR1 | 20.07 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
19 | FRONTSTORAGEFLR1 | 12.54 | 0.0 | N/A | 0.000 | 4.090 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.090 | No |
20 | REARSTAIRSFLR2 | 20.07 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
21 | CORRIDORFLR2 | 125.42 | 0.0 | N/A | 0.000 | 5.296 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.296 | No |
22 | REARSTORAGEFLR2 | 20.07 | 0.0 | N/A | 0.000 | 4.090 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.090 | No |
23 | GUESTROOM201 | 32.61 | 1.5 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
24 | GUESTROOM202_205 | 130.45 | 6.0 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
25 | GUESTROOM206_208 | 105.36 | 4.5 | 23.413 | 4.271E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
26 | GUESTROOM209_212 | 130.45 | 6.0 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
27 | GUESTROOM213 | 32.61 | 1.5 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
28 | GUESTROOM214 | 32.61 | 1.5 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
29 | GUESTROOM215_218 | 130.44 | 6.0 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
30 | ELEVATORCOREFLR2 | 15.05 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
31 | GUESTROOM219 | 32.61 | 1.5 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
32 | GUESTROOM220_223 | 130.44 | 6.0 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
33 | GUESTROOM224 | 32.61 | 1.5 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
34 | FRONTSTORAGEFLR2 | 12.54 | 0.0 | N/A | 0.000 | 4.090 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.090 | No |
35 | FRONTSTAIRSFLR2 | 20.07 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
36 | REARSTAIRSFLR3 | 20.07 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
37 | CORRIDORFLR3 | 125.42 | 0.0 | N/A | 0.000 | 5.296 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.296 | No |
38 | REARSTORAGEFLR3 | 20.07 | 0.0 | N/A | 0.000 | 4.090 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.090 | No |
39 | GUESTROOM301 | 32.61 | 1.5 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
40 | GUESTROOM302_305 | 130.45 | 6.0 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
41 | GUESTROOM306_308 | 105.36 | 4.5 | 23.413 | 4.271E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
42 | GUESTROOM309_312 | 130.45 | 6.0 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
43 | GUESTROOM313 | 32.61 | 1.5 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
44 | GUESTROOM314 | 32.61 | 1.5 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
45 | GUESTROOM315_318 | 130.44 | 6.0 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
46 | ELEVATORCOREFLR3 | 15.05 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
47 | GUESTROOM319 | 32.61 | 1.5 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
48 | GUESTROOM320_323 | 130.44 | 6.0 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
49 | GUESTROOM324 | 32.61 | 1.5 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
50 | FRONTSTORAGEFLR3 | 12.54 | 0.0 | N/A | 0.000 | 4.090 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.090 | No |
51 | FRONTSTAIRSFLR3 | 20.07 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
52 | REARSTAIRSFLR4 | 20.07 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
53 | CORRIDORFLR4 | 125.42 | 0.0 | N/A | 0.000 | 5.296 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.296 | No |
54 | REARSTORAGEFLR4 | 20.07 | 0.0 | N/A | 0.000 | 4.090 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.090 | No |
55 | GUESTROOM401 | 32.61 | 1.5 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
56 | GUESTROOM402_405 | 130.45 | 6.0 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
57 | GUESTROOM406_408 | 105.36 | 4.5 | 23.413 | 4.271E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
58 | GUESTROOM409_412 | 130.45 | 6.0 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
59 | GUESTROOM413 | 32.61 | 1.5 | 21.741 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
60 | GUESTROOM414 | 32.61 | 1.5 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
61 | GUESTROOM415_418 | 130.44 | 6.0 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
62 | ELEVATORCOREFLR4 | 15.05 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
63 | GUESTROOM419 | 32.61 | 1.5 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
64 | GUESTROOM420_423 | 130.44 | 6.0 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
65 | GUESTROOM424 | 32.61 | 1.5 | 21.739 | 4.600E-002 | 4.413 | 11.893 | 0.000 | 0.000 | 0.000 | 0.000 | 16.307 | No |
66 | FRONTSTORAGEFLR4 | 12.54 | 0.0 | N/A | 0.000 | 4.090 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.090 | No |
67 | FRONTSTAIRSFLR4 | 20.07 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
1 | CORRIDORFLR1_PEOPLE | ALWAYSOFF | CORRIDORFLR1 | 150.51 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
2 | CORRIDORFLR2_PEOPLE | ALWAYSOFF | CORRIDORFLR2 | 125.42 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
3 | CORRIDORFLR3_PEOPLE | ALWAYSOFF | CORRIDORFLR3 | 125.42 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
4 | CORRIDORFLR4_PEOPLE | ALWAYSOFF | CORRIDORFLR4 | 125.42 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
5 | ELEVATORCOREFLR1_PEOPLE | ALWAYSOFF | ELEVATORCOREFLR1 | 15.05 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
6 | ELEVATORCOREFLR2_PEOPLE | ALWAYSOFF | ELEVATORCOREFLR2 | 15.05 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
7 | ELEVATORCOREFLR3_PEOPLE | ALWAYSOFF | ELEVATORCOREFLR3 | 15.05 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
8 | ELEVATORCOREFLR4_PEOPLE | ALWAYSOFF | ELEVATORCOREFLR4 | 15.05 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
9 | EMPLOYEELOUNGEFLR1_PEOPLE | EMPLOYEELOUNGE_OCC_SCH | EMPLOYEELOUNGEFLR1 | 32.61 | 18.0 | 18.0 | 0.552 | 1.812 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 18 |
10 | EXERCISECENTERFLR1_PEOPLE | EXERCISECENTER_OCC_SCH | EXERCISECENTERFLR1 | 32.61 | 7.0 | 7.0 | 0.215 | 4.658 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 |
11 | FRONTLOUNGEFLR1_PEOPLE | LOBBY_OCC_SCH | FRONTLOUNGEFLR1 | 163.06 | 53.0 | 53.0 | 0.325 | 3.077 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 |
12 | FRONTOFFICEFLR1_PEOPLE | OFFICE_OCC_W_SB_SCH | FRONTOFFICEFLR1 | 130.44 | 10.0 | 10.0 | 7.667E-002 | 13.044 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 10 |
13 | FRONTSTAIRSFLR1_PEOPLE | ALWAYSOFF | FRONTSTAIRSFLR1 | 20.07 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
14 | FRONTSTAIRSFLR2_PEOPLE | ALWAYSOFF | FRONTSTAIRSFLR2 | 20.07 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
15 | FRONTSTAIRSFLR3_PEOPLE | ALWAYSOFF | FRONTSTAIRSFLR3 | 20.07 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
16 | FRONTSTAIRSFLR4_PEOPLE | ALWAYSOFF | FRONTSTAIRSFLR4 | 20.07 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
17 | FRONTSTORAGEFLR1_PEOPLE | ALWAYSOFF | FRONTSTORAGEFLR1 | 12.54 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
18 | FRONTSTORAGEFLR2_PEOPLE | ALWAYSOFF | FRONTSTORAGEFLR2 | 12.54 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
19 | FRONTSTORAGEFLR3_PEOPLE | ALWAYSOFF | FRONTSTORAGEFLR3 | 12.54 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
20 | FRONTSTORAGEFLR4_PEOPLE | ALWAYSOFF | FRONTSTORAGEFLR4 | 12.54 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
21 | GUESTROOM101_PEOPLE | ALWAYSOFF | GUESTROOM101 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
22 | GUESTROOM102_PEOPLE | ALWAYSOFF | GUESTROOM102 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
23 | GUESTROOM103_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM103 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 |
24 | GUESTROOM104_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM104 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 |
25 | GUESTROOM105_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM105 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 |
26 | GUESTROOM201_PEOPLE | ALWAYSOFF | GUESTROOM201 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
27 | GUESTROOM202_205_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM202_205 | 130.45 | 6.0 | 6.0 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 6 |
28 | GUESTROOM206_208_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM206_208 | 105.36 | 4.5 | 4.5 | 4.271E-002 | 23.413 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 5 |
29 | GUESTROOM209_212_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM209_212 | 130.45 | 6.0 | 6.0 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 6 |
30 | GUESTROOM213_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM213 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 |
31 | GUESTROOM214_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM214 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 |
32 | GUESTROOM215_218_PEOPLE | ALWAYSOFF | GUESTROOM215_218 | 130.44 | 6.0 | 6.0 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
33 | GUESTROOM219_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM219 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 |
34 | GUESTROOM220_223_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM220_223 | 130.44 | 6.0 | 6.0 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 6 |
35 | GUESTROOM224_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM224 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 |
36 | GUESTROOM301_PEOPLE | ALWAYSOFF | GUESTROOM301 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
37 | GUESTROOM302_305_PEOPLE | ALWAYSOFF | GUESTROOM302_305 | 130.45 | 6.0 | 6.0 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
38 | GUESTROOM306_308_PEOPLE | ALWAYSOFF | GUESTROOM306_308 | 105.36 | 4.5 | 4.5 | 4.271E-002 | 23.413 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
39 | GUESTROOM309_312_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM309_312 | 130.45 | 6.0 | 6.0 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 6 |
40 | GUESTROOM313_PEOPLE | ALWAYSOFF | GUESTROOM313 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
41 | GUESTROOM314_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM314 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 |
42 | GUESTROOM315_318_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM315_318 | 130.44 | 6.0 | 6.0 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 6 |
43 | GUESTROOM319_PEOPLE | ALWAYSOFF | GUESTROOM319 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
44 | GUESTROOM320_323_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM320_323 | 130.44 | 6.0 | 6.0 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 6 |
45 | GUESTROOM324_PEOPLE | ALWAYSOFF | GUESTROOM324 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
46 | GUESTROOM401_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM401 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 |
47 | GUESTROOM402_405_PEOPLE | ALWAYSOFF | GUESTROOM402_405 | 130.45 | 6.0 | 6.0 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
48 | GUESTROOM406_408_PEOPLE | ALWAYSOFF | GUESTROOM406_408 | 105.36 | 4.5 | 4.5 | 4.271E-002 | 23.413 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
49 | GUESTROOM409_412_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM409_412 | 130.45 | 6.0 | 6.0 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 6 |
50 | GUESTROOM413_PEOPLE | ALWAYSOFF | GUESTROOM413 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.741 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
51 | GUESTROOM414_PEOPLE | ALWAYSOFF | GUESTROOM414 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
52 | GUESTROOM415_418_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM415_418 | 130.44 | 6.0 | 6.0 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 6 |
53 | GUESTROOM419_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM419 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 |
54 | GUESTROOM420_423_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM420_423 | 130.44 | 6.0 | 6.0 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 6 |
55 | GUESTROOM424_PEOPLE | GUESTROOM_OCC_SCH | GUESTROOM424 | 32.61 | 1.5 | 1.5 | 4.600E-002 | 21.739 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 |
56 | LAUNDRYROOMFLR1_PEOPLE | LAUNDRYROOM_OCC_SCH | LAUNDRYROOMFLR1 | 97.83 | 11.0 | 11.0 | 0.112 | 8.893 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 |
57 | MECHANICALROOMFLR1_PEOPLE | ALWAYSOFF | MECHANICALROOMFLR1 | 32.61 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
58 | MEETINGROOMFLR1_PEOPLE | MEETINGROOM_OCC_W_SB_SCH | MEETINGROOMFLR1 | 80.27 | 43.0 | 43.0 | 0.536 | 1.867 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 43 |
59 | REARSTAIRSFLR1_PEOPLE | ALWAYSOFF | REARSTAIRSFLR1 | 20.07 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
60 | REARSTAIRSFLR2_PEOPLE | ALWAYSOFF | REARSTAIRSFLR2 | 20.07 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
61 | REARSTAIRSFLR3_PEOPLE | ALWAYSOFF | REARSTAIRSFLR3 | 20.07 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
62 | REARSTAIRSFLR4_PEOPLE | ALWAYSOFF | REARSTAIRSFLR4 | 20.07 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
63 | REARSTORAGEFLR1_PEOPLE | ALWAYSOFF | REARSTORAGEFLR1 | 20.07 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
64 | REARSTORAGEFLR2_PEOPLE | ALWAYSOFF | REARSTORAGEFLR2 | 20.07 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
65 | REARSTORAGEFLR3_PEOPLE | ALWAYSOFF | REARSTORAGEFLR3 | 20.07 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
66 | REARSTORAGEFLR4_PEOPLE | ALWAYSOFF | REARSTORAGEFLR4 | 20.07 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 |
67 | RESTROOMFLR1_PEOPLE | LOBBY_OCC_SCH | RESTROOMFLR1 | 32.61 | 1.0 | 1.0 | 3.066E-002 | 32.611 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | CORRIDORFLR1_LIGHTS | BLDG_LIGHT_CORRIDOR_SCH | CORRIDORFLR1 | 150.51 | 0.0 | 797.055 | 5.296 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 518.086 | 518.086 |
2 | CORRIDORFLR2_LIGHTS | BLDG_LIGHT_CORRIDOR_SCH | CORRIDORFLR2 | 125.42 | 0.0 | 664.206 | 5.296 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 431.734 | 431.734 |
3 | CORRIDORFLR3_LIGHTS | BLDG_LIGHT_CORRIDOR_SCH | CORRIDORFLR3 | 125.42 | 0.0 | 664.206 | 5.296 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 431.734 | 431.734 |
4 | CORRIDORFLR4_LIGHTS | BLDG_LIGHT_CORRIDOR_SCH | CORRIDORFLR4 | 125.42 | 0.0 | 664.206 | 5.296 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 431.734 | 431.734 |
5 | ELEVATORCOREFLR1_LIGHTS | ALWAYSOFF | ELEVATORCOREFLR1 | 15.05 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
6 | ELEVATORCOREFLR2_LIGHTS | ALWAYSOFF | ELEVATORCOREFLR2 | 15.05 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
7 | ELEVATORCOREFLR3_LIGHTS | ALWAYSOFF | ELEVATORCOREFLR3 | 15.05 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
8 | ELEVATORCOREFLR4_LIGHTS | ALWAYSOFF | ELEVATORCOREFLR4 | 15.05 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
9 | EMPLOYEELOUNGEFLR1_LIGHTS | BLDG_LIGHT_EMPLOYEELOUNGE_SCH | EMPLOYEELOUNGEFLR1 | 32.61 | 18.0 | 147.420 | 4.521 | 8.190 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 147.420 |
10 | EXERCISECENTERFLR1_LIGHTS | BLDG_LIGHT_EXERCENTER_SCH | EXERCISECENTERFLR1 | 32.61 | 7.0 | 379.080 | 11.625 | 54.154 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 379.080 |
11 | FRONTLOUNGEFLR1_LIGHTS | BLDG_LIGHT_FRONTLOUNGE_SCH | FRONTLOUNGEFLR1 | 163.06 | 53.0 | 895.114 | 5.490 | 16.889 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 895.114 |
12 | FRONTOFFICEFLR1_LIGHTS | BLDG_LIGHT_OFFICE_SCH | FRONTOFFICEFLR1 | 130.44 | 10.0 | 1038.960 | 7.965 | 103.896 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1038.960 |
13 | FRONTSTAIRSFLR1_LIGHTS | BLDG_LIGHT_STAIR_SCH | FRONTSTAIRSFLR1 | 20.07 | 0.0 | 105.840 | 5.274 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 58.212 | 58.212 |
14 | FRONTSTAIRSFLR2_LIGHTS | BLDG_LIGHT_STAIR_SCH | FRONTSTAIRSFLR2 | 20.07 | 0.0 | 105.840 | 5.274 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 58.212 | 58.212 |
15 | FRONTSTAIRSFLR3_LIGHTS | BLDG_LIGHT_STAIR_SCH | FRONTSTAIRSFLR3 | 20.07 | 0.0 | 105.840 | 5.274 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 58.212 | 58.212 |
16 | FRONTSTAIRSFLR4_LIGHTS | BLDG_LIGHT_STAIR_SCH | FRONTSTAIRSFLR4 | 20.07 | 0.0 | 105.840 | 5.274 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 58.212 | 58.212 |
17 | FRONTSTORAGEFLR1_LIGHTS | BLDG_LIGHT_STORAGE_SCH | FRONTSTORAGEFLR1 | 12.54 | 0.0 | 51.300 | 4.090 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 51.300 |
18 | FRONTSTORAGEFLR2_LIGHTS | BLDG_LIGHT_STORAGE_SCH | FRONTSTORAGEFLR2 | 12.54 | 0.0 | 51.300 | 4.090 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 51.300 |
19 | FRONTSTORAGEFLR3_LIGHTS | BLDG_LIGHT_STORAGE_SCH | FRONTSTORAGEFLR3 | 12.54 | 0.0 | 51.300 | 4.090 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 51.300 |
20 | FRONTSTORAGEFLR4_LIGHTS | BLDG_LIGHT_STORAGE_SCH | FRONTSTORAGEFLR4 | 12.54 | 0.0 | 51.300 | 4.090 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 51.300 |
21 | GUESTROOM101_LIGHTS | ALWAYSOFF | GUESTROOM101 | 32.61 | 1.5 | 143.920 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
22 | GUESTROOM102_LIGHTS | ALWAYSOFF | GUESTROOM102 | 32.61 | 1.5 | 143.920 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
23 | GUESTROOM103_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM103 | 32.61 | 1.5 | 143.920 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 143.920 |
24 | GUESTROOM104_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM104 | 32.61 | 1.5 | 143.910 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 143.910 |
25 | GUESTROOM105_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM105 | 32.61 | 1.5 | 143.910 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 143.910 |
26 | GUESTROOM201_LIGHTS | ALWAYSOFF | GUESTROOM201 | 32.61 | 1.5 | 143.920 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
27 | GUESTROOM202_205_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM202_205 | 130.45 | 6.0 | 575.681 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 575.681 |
28 | GUESTROOM206_208_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM206_208 | 105.36 | 4.5 | 464.973 | 4.413 | 103.327 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 464.973 |
29 | GUESTROOM209_212_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM209_212 | 130.45 | 6.0 | 575.681 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 575.681 |
30 | GUESTROOM213_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM213 | 32.61 | 1.5 | 143.920 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 143.920 |
31 | GUESTROOM214_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM214 | 32.61 | 1.5 | 143.910 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 143.910 |
32 | GUESTROOM215_218_LIGHTS | ALWAYSOFF | GUESTROOM215_218 | 130.44 | 6.0 | 575.640 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
33 | GUESTROOM219_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM219 | 32.61 | 1.5 | 143.910 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 143.910 |
34 | GUESTROOM220_223_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM220_223 | 130.44 | 6.0 | 575.640 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 575.640 |
35 | GUESTROOM224_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM224 | 32.61 | 1.5 | 143.910 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 143.910 |
36 | GUESTROOM301_LIGHTS | ALWAYSOFF | GUESTROOM301 | 32.61 | 1.5 | 143.920 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
37 | GUESTROOM302_305_LIGHTS | ALWAYSOFF | GUESTROOM302_305 | 130.45 | 6.0 | 575.681 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
38 | GUESTROOM306_308_LIGHTS | ALWAYSOFF | GUESTROOM306_308 | 105.36 | 4.5 | 464.973 | 4.413 | 103.327 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
39 | GUESTROOM309_312_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM309_312 | 130.45 | 6.0 | 575.681 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 575.681 |
40 | GUESTROOM313_LIGHTS | ALWAYSOFF | GUESTROOM313 | 32.61 | 1.5 | 143.920 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
41 | GUESTROOM314_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM314 | 32.61 | 1.5 | 143.910 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 143.910 |
42 | GUESTROOM315_318_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM315_318 | 130.44 | 6.0 | 575.640 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 575.640 |
43 | GUESTROOM319_LIGHTS | ALWAYSOFF | GUESTROOM319 | 32.61 | 1.5 | 143.910 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
44 | GUESTROOM320_323_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM320_323 | 130.44 | 6.0 | 575.640 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 575.640 |
45 | GUESTROOM324_LIGHTS | ALWAYSOFF | GUESTROOM324 | 32.61 | 1.5 | 143.910 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
46 | GUESTROOM401_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM401 | 32.61 | 1.5 | 143.920 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 143.920 |
47 | GUESTROOM402_405_LIGHTS | ALWAYSOFF | GUESTROOM402_405 | 130.45 | 6.0 | 575.681 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
48 | GUESTROOM406_408_LIGHTS | ALWAYSOFF | GUESTROOM406_408 | 105.36 | 4.5 | 464.973 | 4.413 | 103.327 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
49 | GUESTROOM409_412_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM409_412 | 130.45 | 6.0 | 575.681 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 575.681 |
50 | GUESTROOM413_LIGHTS | ALWAYSOFF | GUESTROOM413 | 32.61 | 1.5 | 143.920 | 4.413 | 95.947 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
51 | GUESTROOM414_LIGHTS | ALWAYSOFF | GUESTROOM414 | 32.61 | 1.5 | 143.910 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
52 | GUESTROOM415_418_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM415_418 | 130.44 | 6.0 | 575.640 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 575.640 |
53 | GUESTROOM419_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM419 | 32.61 | 1.5 | 143.910 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 143.910 |
54 | GUESTROOM420_423_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM420_423 | 130.44 | 6.0 | 575.640 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 575.640 |
55 | GUESTROOM424_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | GUESTROOM424 | 32.61 | 1.5 | 143.910 | 4.413 | 95.940 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 143.910 |
56 | LAUNDRYROOMFLR1_LIGHTS | BLDG_LIGHT_LAUNDRY_SCH | LAUNDRYROOMFLR1 | 97.83 | 11.0 | 558.090 | 5.705 | 50.735 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 558.090 |
57 | MECHANICALROOMFLR1_LIGHTS | BLDG_LIGHT_MECHROOM_SCH | MECHANICALROOMFLR1 | 32.61 | 0.0 | 333.474 | 10.226 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 333.474 |
58 | MEETINGROOMFLR1_LIGHTS | BLDG_LIGHT_MEETINGROOM_SCH | MEETINGROOMFLR1 | 80.27 | 43.0 | 838.139 | 10.441 | 19.492 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 838.139 |
59 | REARSTAIRSFLR1_LIGHTS | BLDG_LIGHT_STAIR_SCH | REARSTAIRSFLR1 | 20.07 | 0.0 | 105.865 | 5.274 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 58.226 | 58.226 |
60 | REARSTAIRSFLR2_LIGHTS | BLDG_LIGHT_STAIR_SCH | REARSTAIRSFLR2 | 20.07 | 0.0 | 105.865 | 5.274 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 58.226 | 58.226 |
61 | REARSTAIRSFLR3_LIGHTS | BLDG_LIGHT_STAIR_SCH | REARSTAIRSFLR3 | 20.07 | 0.0 | 105.865 | 5.274 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 58.226 | 58.226 |
62 | REARSTAIRSFLR4_LIGHTS | BLDG_LIGHT_STAIR_SCH | REARSTAIRSFLR4 | 20.07 | 0.0 | 105.865 | 5.274 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 58.226 | 58.226 |
63 | REARSTORAGEFLR1_LIGHTS | BLDG_LIGHT_STORAGE_SCH | REARSTORAGEFLR1 | 20.07 | 0.0 | 82.105 | 4.090 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 82.105 |
64 | REARSTORAGEFLR2_LIGHTS | BLDG_LIGHT_STORAGE_SCH | REARSTORAGEFLR2 | 20.07 | 0.0 | 82.105 | 4.090 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 82.105 |
65 | REARSTORAGEFLR3_LIGHTS | BLDG_LIGHT_STORAGE_SCH | REARSTORAGEFLR3 | 20.07 | 0.0 | 82.105 | 4.090 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 82.105 |
66 | REARSTORAGEFLR4_LIGHTS | BLDG_LIGHT_STORAGE_SCH | REARSTORAGEFLR4 | 20.07 | 0.0 | 82.105 | 4.090 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 82.105 |
67 | RESTROOMFLR1_LIGHTS | BLDG_LIGHT_RESTROOM_SCH | RESTROOMFLR1 | 32.61 | 1.0 | 221.146 | 6.781 | 221.146 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 145.956 | 145.956 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | CORRIDORFLR1_PLUGLOAD | ALWAYSOFF | CORRIDORFLR1 | 150.51 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
2 | CORRIDORFLR2_PLUGLOAD | ALWAYSOFF | CORRIDORFLR2 | 125.42 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
3 | CORRIDORFLR3_PLUGLOAD | ALWAYSOFF | CORRIDORFLR3 | 125.42 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
4 | CORRIDORFLR4_PLUGLOAD | ALWAYSOFF | CORRIDORFLR4 | 125.42 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
5 | ELEVATORCOREFLR1_ELEVATORS_EQUIP | BLDG_ELEVATORS | ELEVATORCOREFLR1 | 15.05 | 0.0 | 32109.890 | 2133.506 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLift | 1605.495 | 16054.945 |
6 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_ADD_DF | ELEVATORCOREFLR1 | 15.05 | 0.0 | 125.000 | 8.305 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLightsFan | 6.250 | 62.500 |
7 | ELEVATORCOREFLR2_PLUGLOAD | ALWAYSOFF | ELEVATORCOREFLR2 | 15.05 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
8 | ELEVATORCOREFLR3_PLUGLOAD | ALWAYSOFF | ELEVATORCOREFLR3 | 15.05 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
9 | ELEVATORCOREFLR4_PLUGLOAD | ALWAYSOFF | ELEVATORCOREFLR4 | 15.05 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
10 | EMPLOYEELOUNGEFLR1_PLUGLOAD | EMPLOYEELOUNGE_EQP_SCH | EMPLOYEELOUNGEFLR1 | 32.61 | 18.0 | 701.419 | 21.510 | 38.968 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 701.419 |
11 | EXERCISECENTERFLR1_PLUGLOAD | EXERCISECENTER_EQP_SCH | EXERCISECENTERFLR1 | 32.61 | 7.0 | 606.201 | 18.590 | 86.600 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 606.201 |
12 | FRONTLOUNGEFLR1_PLUGLOAD | LOBBY_EQP_SCH | FRONTLOUNGEFLR1 | 163.06 | 53.0 | 4249.250 | 26.060 | 80.175 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 4249.250 |
13 | FRONTOFFICEFLR1_PLUGLOAD | OFF_EQUIP_SCH | FRONTOFFICEFLR1 | 130.44 | 10.0 | 1797.406 | 13.780 | 179.741 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1797.406 |
14 | FRONTSTAIRSFLR1_PLUGLOAD | ALWAYSOFF | FRONTSTAIRSFLR1 | 20.07 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
15 | FRONTSTAIRSFLR2_PLUGLOAD | ALWAYSOFF | FRONTSTAIRSFLR2 | 20.07 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
16 | FRONTSTAIRSFLR3_PLUGLOAD | ALWAYSOFF | FRONTSTAIRSFLR3 | 20.07 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
17 | FRONTSTAIRSFLR4_PLUGLOAD | ALWAYSOFF | FRONTSTAIRSFLR4 | 20.07 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
18 | FRONTSTORAGEFLR1_PLUGLOAD | ALWAYSOFF | FRONTSTORAGEFLR1 | 12.54 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
19 | FRONTSTORAGEFLR2_PLUGLOAD | ALWAYSOFF | FRONTSTORAGEFLR2 | 12.54 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
20 | FRONTSTORAGEFLR3_PLUGLOAD | ALWAYSOFF | FRONTSTORAGEFLR3 | 12.54 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
21 | FRONTSTORAGEFLR4_PLUGLOAD | ALWAYSOFF | FRONTSTORAGEFLR4 | 12.54 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
22 | GUESTROOM101_PLUGLOAD | ALWAYSOFF | GUESTROOM101 | 32.61 | 1.5 | 387.861 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
23 | GUESTROOM102_PLUGLOAD | ALWAYSOFF | GUESTROOM102 | 32.61 | 1.5 | 387.861 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
24 | GUESTROOM103_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM103 | 32.61 | 1.5 | 387.861 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 387.861 |
25 | GUESTROOM104_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM104 | 32.61 | 1.5 | 387.833 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 387.833 |
26 | GUESTROOM105_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM105 | 32.61 | 1.5 | 387.833 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 387.833 |
27 | GUESTROOM201_PLUGLOAD | ALWAYSOFF | GUESTROOM201 | 32.61 | 1.5 | 387.861 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
28 | GUESTROOM202_205_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM202_205 | 130.45 | 6.0 | 1551.444 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1551.444 |
29 | GUESTROOM206_208_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM206_208 | 105.36 | 4.5 | 1253.089 | 11.893 | 278.464 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1253.089 |
30 | GUESTROOM209_212_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM209_212 | 130.45 | 6.0 | 1551.444 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1551.444 |
31 | GUESTROOM213_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM213 | 32.61 | 1.5 | 387.861 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 387.861 |
32 | GUESTROOM214_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM214 | 32.61 | 1.5 | 387.833 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 387.833 |
33 | GUESTROOM215_218_PLUGLOAD | ALWAYSOFF | GUESTROOM215_218 | 130.44 | 6.0 | 1551.334 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
34 | GUESTROOM219_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM219 | 32.61 | 1.5 | 387.833 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 387.833 |
35 | GUESTROOM220_223_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM220_223 | 130.44 | 6.0 | 1551.334 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1551.334 |
36 | GUESTROOM224_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM224 | 32.61 | 1.5 | 387.833 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 387.833 |
37 | GUESTROOM301_PLUGLOAD | ALWAYSOFF | GUESTROOM301 | 32.61 | 1.5 | 387.861 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
38 | GUESTROOM302_305_PLUGLOAD | ALWAYSOFF | GUESTROOM302_305 | 130.45 | 6.0 | 1551.444 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
39 | GUESTROOM306_308_PLUGLOAD | ALWAYSOFF | GUESTROOM306_308 | 105.36 | 4.5 | 1253.089 | 11.893 | 278.464 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
40 | GUESTROOM309_312_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM309_312 | 130.45 | 6.0 | 1551.444 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1551.444 |
41 | GUESTROOM313_PLUGLOAD | ALWAYSOFF | GUESTROOM313 | 32.61 | 1.5 | 387.861 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
42 | GUESTROOM314_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM314 | 32.61 | 1.5 | 387.833 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 387.833 |
43 | GUESTROOM315_318_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM315_318 | 130.44 | 6.0 | 1551.334 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1551.334 |
44 | GUESTROOM319_PLUGLOAD | ALWAYSOFF | GUESTROOM319 | 32.61 | 1.5 | 387.833 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
45 | GUESTROOM320_323_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM320_323 | 130.44 | 6.0 | 1551.334 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1551.334 |
46 | GUESTROOM324_PLUGLOAD | ALWAYSOFF | GUESTROOM324 | 32.61 | 1.5 | 387.833 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
47 | GUESTROOM401_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM401 | 32.61 | 1.5 | 387.861 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 387.861 |
48 | GUESTROOM402_405_PLUGLOAD | ALWAYSOFF | GUESTROOM402_405 | 130.45 | 6.0 | 1551.444 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
49 | GUESTROOM406_408_PLUGLOAD | ALWAYSOFF | GUESTROOM406_408 | 105.36 | 4.5 | 1253.089 | 11.893 | 278.464 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
50 | GUESTROOM409_412_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM409_412 | 130.45 | 6.0 | 1551.444 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1551.444 |
51 | GUESTROOM413_PLUGLOAD | ALWAYSOFF | GUESTROOM413 | 32.61 | 1.5 | 387.861 | 11.893 | 258.574 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
52 | GUESTROOM414_PLUGLOAD | ALWAYSOFF | GUESTROOM414 | 32.61 | 1.5 | 387.833 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
53 | GUESTROOM415_418_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM415_418 | 130.44 | 6.0 | 1551.334 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1551.334 |
54 | GUESTROOM419_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM419 | 32.61 | 1.5 | 387.833 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 387.833 |
55 | GUESTROOM420_423_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM420_423 | 130.44 | 6.0 | 1551.334 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1551.334 |
56 | GUESTROOM424_PLUGLOAD | GUESTROOM_EQP_SCH_ADVA | GUESTROOM424 | 32.61 | 1.5 | 387.833 | 11.893 | 258.556 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 387.833 |
57 | MECHANICALROOMFLR1_PLUGLOAD | ALWAYSOFF | MECHANICALROOMFLR1 | 32.61 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
58 | MEETINGROOMFLR1_PLUGLOAD | MEETINGROOM_EQP_SCH | MEETINGROOMFLR1 | 80.27 | 43.0 | 496.093 | 6.180 | 11.537 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 237.692 |
59 | REARSTAIRSFLR1_PLUGLOAD | ALWAYSOFF | REARSTAIRSFLR1 | 20.07 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
60 | REARSTAIRSFLR2_PLUGLOAD | ALWAYSOFF | REARSTAIRSFLR2 | 20.07 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
61 | REARSTAIRSFLR3_PLUGLOAD | ALWAYSOFF | REARSTAIRSFLR3 | 20.07 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
62 | REARSTAIRSFLR4_PLUGLOAD | ALWAYSOFF | REARSTAIRSFLR4 | 20.07 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
63 | REARSTORAGEFLR1_PLUGLOAD | ALWAYSOFF | REARSTORAGEFLR1 | 20.07 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
64 | REARSTORAGEFLR2_PLUGLOAD | ALWAYSOFF | REARSTORAGEFLR2 | 20.07 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
65 | REARSTORAGEFLR3_PLUGLOAD | ALWAYSOFF | REARSTORAGEFLR3 | 20.07 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
66 | REARSTORAGEFLR4_PLUGLOAD | ALWAYSOFF | REARSTORAGEFLR4 | 20.07 | 0.0 | 0.000 | 0.000 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
67 | RESTROOMFLR1_PLUGLOAD | ALWAYSOFF | RESTROOMFLR1 | 32.61 | 1.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 0.000 |
68 | LAUNDRY EQUIPMENT 1 | LAUNDRYROOM_EQP_ELEC_SCH | LAUNDRYROOMFLR1 | 97.83 | 11.0 | 2709.075 | 27.693 | 246.280 | 0.000 | 0.200 | 0.000 | 0.800 | Laundry | 0.000 | 2709.075 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | DRYER EQUIPMENT 1 | LAUNDRYROOM_EQP_GAS_SCH | LAUNDRYROOMFLR1 | 97.83 | 11.0 | 40096.028 | 409.867 | 3645.093 | 0.000 | 0.200 | 0.000 | 0.800 | Laundry | 0.000 | 40096.028 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
3 | INT_SLAB_FLOOR | 12 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
4 | INT_SLAB_CEILING | 13 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | VeryRough |
5 | RES_ROOF | 18 | 3 | 3 | 0.167 | 0.2284 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
6 | NONRES_EXT_WALL | 20 | 4 | 7 | 0.167 | 0.5136 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
7 | RES_EXT_WALL | 21 | 4 | 7 | 0.167 | 0.3843 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
8 | S_REARSTAIRSFLR1_0_0_0_FFACTOR | 31 | 2 | 7 | 0.167 | 0.7497 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | S_CORRIDORFLR1_0_0_0_FFACTOR | 32 | 2 | 7 | 0.167 | 0.8294E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | S_REARSTORAGEFLR1_0_0_0_FFACTOR | 33 | 2 | 7 | 0.167 | 0.7497 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | S_FRONTLOUNGEFLR1_0_0_0_FFACTOR | 34 | 2 | 7 | 0.167 | 0.2249 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | S_RESTROOMFLR1_0_0_0_FFACTOR | 35 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | S_MEETINGROOMFLR1_0_0_0_FFACTOR | 36 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | S_MECHANICALROOMFLR1_0_0_0_FFACTOR | 37 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | S_GUESTROOM101_0_0_0_FFACTOR | 38 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
16 | S_GUESTROOM102_0_0_0_FFACTOR | 39 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
17 | S_GUESTROOM103_0_0_0_FFACTOR | 40 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
18 | S_GUESTROOM104_0_0_0_FFACTOR | 41 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
19 | S_GUESTROOM105_0_0_0_FFACTOR | 42 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
20 | S_EMPLOYEELOUNGEFLR1_0_0_0_FFACTOR | 43 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
21 | S_LAUNDRYROOMFLR1_0_0_0_FFACTOR | 44 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
22 | S_ELEVATORCOREFLR1_0_0_0_FFACTOR | 45 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
23 | S_EXERCISECENTERFLR1_0_0_0_FFACTOR | 46 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
24 | S_FRONTOFFICEFLR1_0_0_0_FFACTOR | 47 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
25 | S_FRONTSTAIRSFLR1_0_0_0_FFACTOR | 48 | 2 | 7 | 0.167 | 0.7498 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
26 | S_FRONTSTORAGEFLR1_0_0_0_FFACTOR | 49 | 2 | 7 | 0.167 | 0.1573 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
2 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
3 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
4 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
5 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
6 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
7 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
8 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
9 | RES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.319 |
10 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
11 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
12 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
13 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.713 |
14 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
15 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
16 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
17 | RES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 2.368 |
18 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
19 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 1.257 |
20 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
21 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 11.98 |
22 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
23 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 1.257 |
24 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
25 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.370 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | ~FC_Insulation_6 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
30 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
31 | ~FC_Insulation_7 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
32 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
33 | ~FC_Insulation_8 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
34 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
35 | ~FC_Insulation_9 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
36 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
37 | ~FC_Insulation_10 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
38 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
39 | ~FC_Insulation_11 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
40 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
41 | ~FC_Insulation_12 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
42 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
43 | ~FC_Insulation_13 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
44 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
45 | ~FC_Insulation_14 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
46 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
47 | ~FC_Insulation_15 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
48 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
49 | ~FC_Insulation_16 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
50 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
51 | ~FC_Insulation_17 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
52 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
53 | ~FC_Insulation_18 | 0.0000 | 0.000 | 0.000 | 0.000 | 1.257 |
54 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
55 | ~FC_Insulation_19 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.281 |
56 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.1010000 | 2.1010000 | 2.1010000 | |
3 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
4 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
5 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
6 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
7 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
8 | 7 | 0.43260499E-16 | 0.34524919E-16 | 0.52793240E-17 | 0.0000000 |
9 | 6 | 0.69434179E-09 | 0.98085174E-11 | 0.18162501E-10 | -0.40870994E-12 |
10 | 5 | -0.12888762E-04 | 0.28373718E-06 | -0.16918523E-06 | 0.92361873E-08 |
11 | 4 | 0.25174112E-01 | 0.33697681E-03 | 0.22646198E-03 | -0.31467795E-04 |
12 | 3 | -3.7600775 | 0.27170599E-01 | -0.48495626E-01 | 0.94171705E-02 |
13 | 2 | 51.553741 | 0.22121684 | 1.2284947 | -0.25833933 |
14 | 1 | -128.86110 | 0.21944682 | -5.1479470 | 1.1228340 |
15 | 0 | 81.526494 | 0.16043334E-01 | 4.4519351 | |
16 | 7 | 0.52793240E-17 | 0.34524919E-16 | 0.43260499E-16 | 0.0000000 |
17 | 6 | 0.18162501E-10 | 0.98085174E-11 | 0.69434179E-09 | -0.40870994E-12 |
18 | 5 | -0.16918523E-06 | 0.28373718E-06 | -0.12888762E-04 | 0.92361873E-08 |
19 | 4 | 0.22646198E-03 | 0.33697681E-03 | 0.25174112E-01 | -0.31467795E-04 |
20 | 3 | -0.48495626E-01 | 0.27170599E-01 | -3.7600775 | 0.94171705E-02 |
21 | 2 | 1.2284947 | 0.22121684 | 51.553741 | -0.25833933 |
22 | 1 | -5.1479470 | 0.21944682 | -128.86110 | 1.1228340 |
23 | 0 | 4.4519351 | 0.16043334E-01 | 81.526494 | |
24 | 3 | -0.62451068E-06 | 0.10350887E-08 | -0.38276125E-05 | 0.11995084E-16 |
25 | 2 | 0.77976586 | 0.13989883E-02 | 1.0579789 | -0.73382352E-06 |
26 | 1 | -21.958702 | 0.93426804E-01 | -6.3215779 | 0.20283230 |
27 | 0 | 21.361010 | 0.87247630E-01 | 5.4456762 | |
28 | 7 | -0.33207909E-12 | 0.79542070E-15 | -0.11586622E-12 | 0.10783435E-15 |
29 | 6 | 0.31762832E-07 | 0.14865645E-09 | 0.72503568E-08 | -0.15188138E-12 |
30 | 5 | -0.20568023E-03 | 0.12486053E-05 | -0.10556626E-03 | 0.71569697E-08 |
31 | 4 | 0.31018727 | 0.59758545E-03 | 0.10618022 | -0.36135240E-04 |
32 | 3 | -7.6231853 | 0.18239075E-01 | -2.4448349 | 0.30759039E-01 |
33 | 2 | 42.047589 | 0.63983780E-01 | 15.698525 | -0.34644559 |
34 | 1 | -81.446794 | 0.28535822E-01 | -29.529986 | 1.0978209 |
35 | 0 | 46.824333 | 0.56745654E-03 | 16.282146 | |
36 | 7 | -0.35963630E-12 | 0.61482467E-15 | -0.13288964E-12 | 0.15093609E-15 |
37 | 6 | 0.33258387E-07 | 0.11249777E-09 | 0.75805110E-08 | -0.16019892E-12 |
38 | 5 | -0.21313350E-03 | 0.93714421E-06 | -0.10927814E-03 | 0.74776115E-08 |
39 | 4 | 0.31870195 | 0.44521373E-03 | 0.10925225 | -0.37358013E-04 |
40 | 3 | -7.7913368 | 0.13499397E-01 | -2.4947666 | 0.31584435E-01 |
41 | 2 | 42.601618 | 0.47079245E-01 | 15.902165 | -0.35261900 |
42 | 1 | -81.870774 | 0.20888078E-01 | -29.712230 | 1.1068570 |
43 | 0 | 46.824331 | 0.41326549E-03 | 16.278015 | |
44 | 7 | -0.53128682E-09 | 0.24220376E-16 | 0.26514926E-14 | 0.16128612E-17 |
45 | 6 | 0.21546521E-04 | 0.14761233E-07 | 0.31451383E-02 | -0.26384056E-04 |
46 | 5 | -0.15649836E-02 | 0.87831386E-05 | -0.22118113 | 0.19337009E-02 |
47 | 4 | 0.36052469E-01 | 0.40055374E-03 | 4.7871640 | -0.44857599E-01 |
48 | 3 | -0.31659804 | 0.31924535E-02 | -37.781903 | 0.39600649 |
49 | 2 | 1.1239880 | 0.53187163E-02 | 116.01766 | -1.4117025 |
50 | 1 | -1.6220914 | 0.16257908E-02 | -143.63277 | 2.0445274 |
51 | 0 | 0.79077713 | 0.38479517E-04 | 60.838472 | |
52 | 7 | -0.51500745E-08 | -0.97097940E-14 | 0.12078333E-14 | -0.28423254E-16 |
53 | 6 | 0.26273275E-05 | 0.15924315E-08 | 0.31989440E-02 | -0.26835423E-04 |
54 | 5 | -0.17303723E-03 | 0.93841597E-06 | -0.22424021 | 0.19607016E-02 |
55 | 4 | 0.38747196E-02 | 0.42606369E-04 | 4.8381317 | -0.45347518E-01 |
56 | 3 | -0.33688598E-01 | 0.33804754E-03 | -38.069908 | 0.39918977 |
57 | 2 | 0.11914415 | 0.56121933E-03 | 116.57831 | -1.4192015 |
58 | 1 | -0.17165687 | 0.17050824E-03 | -143.96285 | 2.0499529 |
59 | 0 | 0.83614474E-01 | 0.41325042E-05 | 60.838472 | |
60 | 7 | -0.53129722E-09 | 0.23174307E-16 | 0.25222374E-14 | 0.13630250E-17 |
61 | 6 | 0.21546106E-04 | 0.14760998E-07 | 0.31451395E-02 | -0.26384065E-04 |
62 | 5 | -0.15649536E-02 | 0.87829689E-05 | -0.22118120 | 0.19337015E-02 |
63 | 4 | 0.36051778E-01 | 0.40054620E-03 | 4.7871651 | -0.44857610E-01 |
64 | 3 | -0.31659198 | 0.31923921E-02 | -37.781909 | 0.39600656 |
65 | 2 | 1.1239666 | 0.53186170E-02 | 116.01767 | -1.4117026 |
66 | 1 | -1.6220604 | 0.16257564E-02 | -143.63278 | 2.0445275 |
67 | 0 | 0.79076203 | 0.38480293E-04 | 60.838472 | |
68 | 7 | -0.18720363E-08 | -0.47896590E-15 | 0.65414493E-14 | -0.87102839E-16 |
69 | 6 | 0.63019258E-05 | 0.43089118E-08 | 0.31878718E-02 | -0.26742540E-04 |
70 | 5 | -0.45288328E-03 | 0.25526970E-05 | -0.22361101 | 0.19551479E-02 |
71 | 4 | 0.10415606E-01 | 0.11619496E-03 | 4.8276543 | -0.45246799E-01 |
72 | 3 | -0.91458955E-01 | 0.92404132E-03 | -38.010732 | 0.39853565 |
73 | 2 | 0.32474571 | 0.15371787E-02 | 116.46316 | -1.4176612 |
74 | 1 | -0.46871811 | 0.46842216E-03 | -143.89507 | 2.0488387 |
75 | 0 | 0.22852204 | 0.11310110E-04 | 60.838472 | |
76 | 7 | -0.26954509E-08 | -0.14165318E-14 | 0.79352360E-14 | -0.11582431E-15 |
77 | 6 | 0.44852355E-05 | 0.30071832E-08 | 0.31931672E-02 | -0.26786962E-04 |
78 | 5 | -0.31748557E-03 | 0.17794841E-05 | -0.22391198 | 0.19578044E-02 |
79 | 4 | 0.72703152E-02 | 0.80954923E-04 | 4.8326669 | -0.45294985E-01 |
80 | 3 | -0.63742948E-01 | 0.64345195E-03 | -38.039048 | 0.39884864 |
81 | 2 | 0.22619914 | 0.10699397E-02 | 116.51827 | -1.4183983 |
82 | 1 | -0.32639619 | 0.32581351E-03 | -143.92751 | 2.0493720 |
83 | 0 | 0.15911251 | 0.78822336E-05 | 60.838472 | |
84 | 7 | -0.26954509E-08 | -0.14160083E-14 | 0.76220666E-14 | -0.11181341E-15 |
85 | 6 | 0.44852355E-05 | 0.30071829E-08 | 0.31931672E-02 | -0.26786962E-04 |
86 | 5 | -0.31748557E-03 | 0.17794842E-05 | -0.22391198 | 0.19578044E-02 |
87 | 4 | 0.72703152E-02 | 0.80954923E-04 | 4.8326669 | -0.45294985E-01 |
88 | 3 | -0.63742948E-01 | 0.64345196E-03 | -38.039048 | 0.39884864 |
89 | 2 | 0.22619914 | 0.10699397E-02 | 116.51827 | -1.4183983 |
90 | 1 | -0.32639619 | 0.32581353E-03 | -143.92751 | 2.0493720 |
91 | 0 | 0.15911251 | 0.78822226E-05 | 60.838472 | |
92 | 7 | -0.26954509E-08 | -0.14163871E-14 | 0.77130239E-14 | -0.11173131E-15 |
93 | 6 | 0.44852355E-05 | 0.30071832E-08 | 0.31931672E-02 | -0.26786962E-04 |
94 | 5 | -0.31748557E-03 | 0.17794841E-05 | -0.22391198 | 0.19578044E-02 |
95 | 4 | 0.72703152E-02 | 0.80954923E-04 | 4.8326669 | -0.45294985E-01 |
96 | 3 | -0.63742948E-01 | 0.64345195E-03 | -38.039048 | 0.39884864 |
97 | 2 | 0.22619914 | 0.10699397E-02 | 116.51827 | -1.4183983 |
98 | 1 | -0.32639619 | 0.32581351E-03 | -143.92751 | 2.0493720 |
99 | 0 | 0.15911251 | 0.78822328E-05 | 60.838472 | |
100 | 7 | -0.26954509E-08 | -0.14163493E-14 | 0.78169427E-14 | -0.11082736E-15 |
101 | 6 | 0.44852355E-05 | 0.30071832E-08 | 0.31931672E-02 | -0.26786962E-04 |
102 | 5 | -0.31748557E-03 | 0.17794841E-05 | -0.22391198 | 0.19578044E-02 |
103 | 4 | 0.72703152E-02 | 0.80954923E-04 | 4.8326669 | -0.45294985E-01 |
104 | 3 | -0.63742948E-01 | 0.64345195E-03 | -38.039048 | 0.39884864 |
105 | 2 | 0.22619914 | 0.10699397E-02 | 116.51827 | -1.4183983 |
106 | 1 | -0.32639619 | 0.32581351E-03 | -143.92751 | 2.0493720 |
107 | 0 | 0.15911251 | 0.78822328E-05 | 60.838472 | |
108 | 7 | -0.26954509E-08 | -0.14163494E-14 | 0.78169428E-14 | -0.11082736E-15 |
109 | 6 | 0.44852355E-05 | 0.30071832E-08 | 0.31931672E-02 | -0.26786962E-04 |
110 | 5 | -0.31748557E-03 | 0.17794841E-05 | -0.22391198 | 0.19578044E-02 |
111 | 4 | 0.72703152E-02 | 0.80954923E-04 | 4.8326669 | -0.45294985E-01 |
112 | 3 | -0.63742948E-01 | 0.64345195E-03 | -38.039048 | 0.39884864 |
113 | 2 | 0.22619914 | 0.10699397E-02 | 116.51827 | -1.4183983 |
114 | 1 | -0.32639619 | 0.32581351E-03 | -143.92751 | 2.0493720 |
115 | 0 | 0.15911251 | 0.78822328E-05 | 60.838472 | |
116 | 7 | -0.26954509E-08 | -0.14165316E-14 | 0.79352360E-14 | -0.11582431E-15 |
117 | 6 | 0.44852355E-05 | 0.30071832E-08 | 0.31931672E-02 | -0.26786962E-04 |
118 | 5 | -0.31748557E-03 | 0.17794841E-05 | -0.22391198 | 0.19578044E-02 |
119 | 4 | 0.72703152E-02 | 0.80954923E-04 | 4.8326669 | -0.45294985E-01 |
120 | 3 | -0.63742948E-01 | 0.64345195E-03 | -38.039048 | 0.39884864 |
121 | 2 | 0.22619914 | 0.10699397E-02 | 116.51827 | -1.4183983 |
122 | 1 | -0.32639619 | 0.32581351E-03 | -143.92751 | 2.0493720 |
123 | 0 | 0.15911251 | 0.78822336E-05 | 60.838472 | |
124 | 7 | -0.26952518E-08 | -0.14162741E-14 | 0.77444661E-14 | -0.11458787E-15 |
125 | 6 | 0.44855364E-05 | 0.30074020E-08 | 0.31931663E-02 | -0.26786955E-04 |
126 | 5 | -0.31750824E-03 | 0.17796143E-05 | -0.22391193 | 0.19578040E-02 |
127 | 4 | 0.72708434E-02 | 0.80960854E-04 | 4.8326661 | -0.45294977E-01 |
128 | 3 | -0.63747607E-01 | 0.64349918E-03 | -38.039043 | 0.39884859 |
129 | 2 | 0.22621572 | 0.10700184E-02 | 116.51826 | -1.4183982 |
130 | 1 | -0.32642013 | 0.32583753E-03 | -143.92750 | 2.0493719 |
131 | 0 | 0.15912418 | 0.78828025E-05 | 60.838472 | |
132 | 7 | -0.26952518E-08 | -0.14160959E-14 | 0.76668815E-14 | -0.11323979E-15 |
133 | 6 | 0.44855364E-05 | 0.30074019E-08 | 0.31931663E-02 | -0.26786955E-04 |
134 | 5 | -0.31750824E-03 | 0.17796143E-05 | -0.22391193 | 0.19578040E-02 |
135 | 4 | 0.72708434E-02 | 0.80960854E-04 | 4.8326661 | -0.45294977E-01 |
136 | 3 | -0.63747607E-01 | 0.64349918E-03 | -38.039043 | 0.39884859 |
137 | 2 | 0.22621572 | 0.10700184E-02 | 116.51826 | -1.4183982 |
138 | 1 | -0.32642013 | 0.32583754E-03 | -143.92750 | 2.0493719 |
139 | 0 | 0.15912418 | 0.78827986E-05 | 60.838472 | |
140 | 7 | -0.26952518E-08 | -0.14160961E-14 | 0.76668817E-14 | -0.11323979E-15 |
141 | 6 | 0.44855364E-05 | 0.30074019E-08 | 0.31931663E-02 | -0.26786955E-04 |
142 | 5 | -0.31750824E-03 | 0.17796143E-05 | -0.22391193 | 0.19578040E-02 |
143 | 4 | 0.72708434E-02 | 0.80960854E-04 | 4.8326661 | -0.45294977E-01 |
144 | 3 | -0.63747607E-01 | 0.64349918E-03 | -38.039043 | 0.39884859 |
145 | 2 | 0.22621572 | 0.10700184E-02 | 116.51826 | -1.4183982 |
146 | 1 | -0.32642013 | 0.32583754E-03 | -143.92750 | 2.0493719 |
147 | 0 | 0.15912418 | 0.78827986E-05 | 60.838472 | |
148 | 7 | -0.26952518E-08 | -0.14161726E-14 | 0.78921355E-14 | -0.11583298E-15 |
149 | 6 | 0.44855364E-05 | 0.30074019E-08 | 0.31931663E-02 | -0.26786955E-04 |
150 | 5 | -0.31750824E-03 | 0.17796143E-05 | -0.22391193 | 0.19578040E-02 |
151 | 4 | 0.72708434E-02 | 0.80960854E-04 | 4.8326661 | -0.45294977E-01 |
152 | 3 | -0.63747607E-01 | 0.64349918E-03 | -38.039043 | 0.39884859 |
153 | 2 | 0.22621572 | 0.10700184E-02 | 116.51826 | -1.4183982 |
154 | 1 | -0.32642013 | 0.32583754E-03 | -143.92750 | 2.0493719 |
155 | 0 | 0.15912418 | 0.78827986E-05 | 60.838472 | |
156 | 7 | -0.26952518E-08 | -0.14158604E-14 | 0.78355877E-14 | -0.11409465E-15 |
157 | 6 | 0.44855364E-05 | 0.30074019E-08 | 0.31931663E-02 | -0.26786955E-04 |
158 | 5 | -0.31750824E-03 | 0.17796143E-05 | -0.22391193 | 0.19578040E-02 |
159 | 4 | 0.72708434E-02 | 0.80960854E-04 | 4.8326661 | -0.45294977E-01 |
160 | 3 | -0.63747607E-01 | 0.64349918E-03 | -38.039043 | 0.39884859 |
161 | 2 | 0.22621572 | 0.10700184E-02 | 116.51826 | -1.4183982 |
162 | 1 | -0.32642013 | 0.32583754E-03 | -143.92750 | 2.0493719 |
163 | 0 | 0.15912418 | 0.78827985E-05 | 60.838472 | |
164 | 7 | -0.26952518E-08 | -0.14161149E-14 | 0.76709449E-14 | -0.11600230E-15 |
165 | 6 | 0.44855364E-05 | 0.30074020E-08 | 0.31931663E-02 | -0.26786955E-04 |
166 | 5 | -0.31750824E-03 | 0.17796143E-05 | -0.22391193 | 0.19578040E-02 |
167 | 4 | 0.72708434E-02 | 0.80960854E-04 | 4.8326661 | -0.45294977E-01 |
168 | 3 | -0.63747607E-01 | 0.64349918E-03 | -38.039043 | 0.39884859 |
169 | 2 | 0.22621572 | 0.10700184E-02 | 116.51826 | -1.4183982 |
170 | 1 | -0.32642013 | 0.32583753E-03 | -143.92750 | 2.0493719 |
171 | 0 | 0.15912418 | 0.78828026E-05 | 60.838472 | |
172 | 7 | -0.26952518E-08 | -0.14161596E-14 | 0.76816470E-14 | -0.11359384E-15 |
173 | 6 | 0.44855364E-05 | 0.30074019E-08 | 0.31931663E-02 | -0.26786955E-04 |
174 | 5 | -0.31750824E-03 | 0.17796143E-05 | -0.22391193 | 0.19578040E-02 |
175 | 4 | 0.72708434E-02 | 0.80960854E-04 | 4.8326661 | -0.45294977E-01 |
176 | 3 | -0.63747607E-01 | 0.64349918E-03 | -38.039043 | 0.39884859 |
177 | 2 | 0.22621572 | 0.10700184E-02 | 116.51826 | -1.4183982 |
178 | 1 | -0.32642013 | 0.32583754E-03 | -143.92750 | 2.0493719 |
179 | 0 | 0.15912418 | 0.78827986E-05 | 60.838472 | |
180 | 7 | -0.53116838E-09 | 0.26696391E-16 | 0.25662770E-14 | 0.29950102E-17 |
181 | 6 | 0.21551244E-04 | 0.14764408E-07 | 0.31451253E-02 | -0.26383947E-04 |
182 | 5 | -0.15653260E-02 | 0.87850342E-05 | -0.22118039 | 0.19336943E-02 |
183 | 4 | 0.36060337E-01 | 0.40064042E-03 | 4.7871516 | -0.44857481E-01 |
184 | 3 | -0.31666702 | 0.31931462E-02 | -37.781833 | 0.39600572 |
185 | 2 | 1.1242327 | 0.53198728E-02 | 116.01752 | -1.4117006 |
186 | 1 | -1.6224443 | 0.16261452E-02 | -143.63269 | 2.0445261 |
187 | 0 | 0.79094913 | 0.38487883E-04 | 60.838472 | |
188 | 7 | -0.26952518E-08 | -0.14158604E-14 | 0.78355877E-14 | -0.11409465E-15 |
189 | 6 | 0.44855364E-05 | 0.30074019E-08 | 0.31931663E-02 | -0.26786955E-04 |
190 | 5 | -0.31750824E-03 | 0.17796143E-05 | -0.22391193 | 0.19578040E-02 |
191 | 4 | 0.72708434E-02 | 0.80960854E-04 | 4.8326661 | -0.45294977E-01 |
192 | 3 | -0.63747607E-01 | 0.64349918E-03 | -38.039043 | 0.39884859 |
193 | 2 | 0.22621572 | 0.10700184E-02 | 116.51826 | -1.4183982 |
194 | 1 | -0.32642013 | 0.32583754E-03 | -143.92750 | 2.0493719 |
195 | 0 | 0.15912418 | 0.78827986E-05 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.46_SHGC_0.25 | 29 | 1 | VerySmooth | 2.615 | 0.252 | 0.162 | 0.276 |
2 | RESWINDOW_U_0.46_SHGC_0.25 | 30 | 1 | VerySmooth | 2.615 | 0.252 | 0.162 | 0.276 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | GLAZING LAYER | SpectralAverage | 2.53892E-002 | 0.16139 | 0.61607 | 0.61607 | 0.27500 | 0.15630 | 0.22588 | 0.00000 | 0.84000 | 0.84000 | 0.12001 | 1.00000 | No | |
2 | RESIDENTIAL WINDOW GLAZING LAYER | SpectralAverage | 2.53892E-002 | 0.16139 | 0.61607 | 0.61607 | 0.27500 | 0.15630 | 0.22588 | 0.00000 | 0.84000 | 0.84000 | 0.12001 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 20 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Zone Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Zones | |
1 | FRONTLOUNGEFLR1 | 5 | 0 |
2 | MEETINGROOMFLR1 | 3 | 0 |
3 | LAUNDRYROOMFLR1 | 3 | 0 |
4 | FRONTOFFICEFLR1 | 4 | 0 |
Zone Name | Number of Adjacent Zones with Windows | Adjacent Zone Names - 1st 100 (max) | |
1 | FRONTLOUNGEFLR1 | 0 | |
2 | MEETINGROOMFLR1 | 0 | |
3 | LAUNDRYROOMFLR1 | 0 | |
4 | FRONTOFFICEFLR1 | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SHWSYSSHOWER WATER HEATER | 1.1356 | 87921.3 | 0.000 | 0.0000 |
2 | WaterHeater:Mixed | SHWSYSLAUNDRY WATER HEATER | 0.7570 | 58614.2 | 0.799 | 0.4880 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | W_REARSTAIRSFLR1_2_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
2 | W_REARSTAIRSFLR1_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
3 | W_REARSTAIRSFLR1_3_0_0_DOOR | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
4 | P_REARSTAIRSFLR1_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
5 | P_REARSTAIRSFLR1_5_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
6 | S_REARSTAIRSFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
7 | C_REARSTAIRSFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
8 | P_CORRIDORFLR1_10003_0_10002 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
9 | W_CORRIDORFLR1_2_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 4 | No | No |
10 | W_CORRIDORFLR1_2_0_0_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 1 | No | No |
11 | P_CORRIDORFLR1_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
12 | P_CORRIDORFLR1_5_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
13 | P_CORRIDORFLR1_6_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
14 | P_CORRIDORFLR1_7_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
15 | P_CORRIDORFLR1_8_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
16 | P_CORRIDORFLR1_9_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
17 | W_CORRIDORFLR1_10_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 4 | No | No |
18 | W_CORRIDORFLR1_10_0_0_DOOR | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
19 | P_CORRIDORFLR1_11_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
20 | P_CORRIDORFLR1_12_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
21 | P_CORRIDORFLR1_13_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
22 | P_CORRIDORFLR1_14_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
23 | P_CORRIDORFLR1_15_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
24 | W_CORRIDORFLR1_16_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 4 | No | No |
25 | D_CORRIDORFLR1_16_0_0_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 1 | No | No |
26 | P_CORRIDORFLR1_17_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
27 | P_CORRIDORFLR1_18_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
28 | P_CORRIDORFLR1_19_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
29 | W_CORRIDORFLR1_20_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 4 | No | No |
30 | W_CORRIDORFLR1_20_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 1 | No | No |
31 | P_CORRIDORFLR1_21_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
32 | P_CORRIDORFLR1_22_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
33 | P_CORRIDORFLR1_23_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
34 | P_CORRIDORFLR1_24_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
35 | P_CORRIDORFLR1_25_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
36 | P_CORRIDORFLR1_26_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
37 | P_CORRIDORFLR1_27_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
38 | S_CORRIDORFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
39 | C_CORRIDORFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
40 | C_CORRIDORFLR1_1_1_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 4.11 | 0.30 | 0 | No | No |
41 | P_REARSTORAGEFLR1_10027_0_10025 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
42 | W_REARSTORAGEFLR1_2_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
43 | P_REARSTORAGEFLR1_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
44 | W_REARSTORAGEFLR1_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
45 | S_REARSTORAGEFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
46 | C_REARSTORAGEFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
47 | P_FRONTLOUNGEFLR1_10018_0_10016 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 28.04 | 11.63 | 0.16 | 0 | No | No |
48 | P_FRONTLOUNGEFLR1_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 28.04 | 11.63 | 0.16 | 0 | No | No |
49 | W_FRONTLOUNGEFLR1_4_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 3.35 | 28.04 | 11.63 | 0.16 | 4 | No | No |
50 | W_FRONTLOUNGEFLR1_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 28.04 | 11.63 | 0.16 | 3 | No | No |
51 | W_FRONTLOUNGEFLR1_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 28.04 | 11.63 | 0.16 | 2 | No | No |
52 | W_FRONTLOUNGEFLR1_5_0_0_0_1 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 28.04 | 11.63 | 0.16 | 2 | No | No |
53 | W_FRONTLOUNGEFLR1_5_0_0_0_2 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 28.04 | 11.63 | 0.16 | 2 | No | No |
54 | W_FRONTLOUNGEFLR1_5_0_0_0_3 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 28.04 | 11.63 | 0.16 | 2 | No | No |
55 | W_FRONTLOUNGEFLR1_5_0_0_0_4 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 28.04 | 11.63 | 0.16 | 2 | No | No |
56 | S_FRONTLOUNGEFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 28.04 | 11.63 | 0.16 | 0 | No | No |
57 | C_FRONTLOUNGEFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 28.04 | 11.63 | 0.16 | 0 | No | No |
58 | C_FRONTLOUNGEFLR1_1_1_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 28.04 | 11.63 | 0.16 | 0 | No | No |
59 | P_RESTROOMFLR1_10019_0_10017 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.00 | 0 | No | No |
60 | P_RESTROOMFLR1_10020_0_10018 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.00 | 0 | No | No |
61 | P_RESTROOMFLR1_10033_0_10030 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.00 | 0 | No | No |
62 | W_RESTROOMFLR1_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.00 | 0 | No | No |
63 | S_RESTROOMFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.00 | 0 | No | No |
64 | C_RESTROOMFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.00 | 0 | No | No |
65 | P_MEETINGROOMFLR1_10021_0_10019 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 8.93 | 0.15 | 0 | No | No |
66 | P_MEETINGROOMFLR1_10022_0_10020 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 8.93 | 0.15 | 0 | No | No |
67 | P_MEETINGROOMFLR1_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 8.93 | 0.15 | 0 | No | No |
68 | W_MEETINGROOMFLR1_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 9.75 | 8.93 | 0.15 | 3 | No | No |
69 | W_MEETINGROOMFLR1_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 9.75 | 8.93 | 0.15 | 2 | No | No |
70 | W_MEETINGROOMFLR1_5_0_0_0_1 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 9.75 | 8.93 | 0.15 | 2 | No | No |
71 | W_MEETINGROOMFLR1_5_0_0_0_2 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 9.75 | 8.93 | 0.15 | 2 | No | No |
72 | S_MEETINGROOMFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 8.93 | 0.15 | 0 | No | No |
73 | C_MEETINGROOMFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 8.93 | 0.15 | 0 | No | No |
74 | C_MEETINGROOMFLR1_1_1_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 9.75 | 8.93 | 0.15 | 0 | No | No |
75 | P_MECHANICALROOMFLR1_10023_0_10021 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.00 | 0 | No | No |
76 | P_MECHANICALROOMFLR1_10041_0_10034 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.00 | 0 | No | No |
77 | P_MECHANICALROOMFLR1_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.00 | 0 | No | No |
78 | W_MECHANICALROOMFLR1_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.00 | 0 | No | No |
79 | S_MECHANICALROOMFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.00 | 0 | No | No |
80 | C_MECHANICALROOMFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.00 | 0 | No | No |
81 | P_GUESTROOM101_10024_0_10022 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
82 | P_GUESTROOM101_10045_0_10036 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
83 | P_GUESTROOM101_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
84 | W_GUESTROOM101_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 4 | No | No |
85 | W_GUESTROOM101_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 2 | No | No |
86 | S_GUESTROOM101_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
87 | C_GUESTROOM101_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
88 | P_GUESTROOM102_10025_0_10023 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
89 | P_GUESTROOM102_10049_0_10038 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
90 | P_GUESTROOM102_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
91 | W_GUESTROOM102_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 4 | No | No |
92 | W_GUESTROOM102_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 2 | No | No |
93 | S_GUESTROOM102_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
94 | C_GUESTROOM102_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
95 | P_GUESTROOM103_10026_0_10024 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
96 | P_GUESTROOM103_10030_0_10027 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
97 | P_GUESTROOM103_10053_0_10040 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
98 | W_GUESTROOM103_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 4 | No | No |
99 | W_GUESTROOM103_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 2 | No | No |
100 | S_GUESTROOM103_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
101 | C_GUESTROOM103_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
102 | P_GUESTROOM104_10002_0_10001 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
103 | P_GUESTROOM104_10007_0_10005 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
104 | W_GUESTROOM104_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 4 | No | No |
105 | W_GUESTROOM104_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 1 | No | No |
106 | P_GUESTROOM104_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
107 | S_GUESTROOM104_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
108 | C_GUESTROOM104_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
109 | P_GUESTROOM105_10008_0_10006 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
110 | P_GUESTROOM105_10062_0_10043 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
111 | W_GUESTROOM105_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 4 | No | No |
112 | W_GUESTROOM105_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 2 | No | No |
113 | P_GUESTROOM105_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
114 | S_GUESTROOM105_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
115 | C_GUESTROOM105_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
116 | P_EMPLOYEELOUNGEFLR1_10009_0_10007 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
117 | P_EMPLOYEELOUNGEFLR1_10066_0_10045 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
118 | W_EMPLOYEELOUNGEFLR1_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 4 | No | No |
119 | W_EMPLOYEELOUNGEFLR1_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 1 | No | No |
120 | P_EMPLOYEELOUNGEFLR1_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
121 | S_EMPLOYEELOUNGEFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
122 | C_EMPLOYEELOUNGEFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
123 | P_LAUNDRYROOMFLR1_10010_0_10008 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 11.89 | 9.73 | 0.12 | 0 | No | No |
124 | P_LAUNDRYROOMFLR1_10070_0_10047 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 11.89 | 9.73 | 0.12 | 0 | No | No |
125 | W_LAUNDRYROOMFLR1_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 11.89 | 9.73 | 0.12 | 4 | No | No |
126 | W_LAUNDRYROOMFLR1_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 11.89 | 9.73 | 0.12 | 2 | No | No |
127 | W_LAUNDRYROOMFLR1_3_0_0_0_1 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 11.89 | 9.73 | 0.12 | 2 | No | No |
128 | W_LAUNDRYROOMFLR1_3_0_0_0_2 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 11.89 | 9.73 | 0.12 | 2 | No | No |
129 | P_LAUNDRYROOMFLR1_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 11.89 | 9.73 | 0.12 | 0 | No | No |
130 | S_LAUNDRYROOMFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 11.89 | 9.73 | 0.12 | 0 | No | No |
131 | C_LAUNDRYROOMFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 11.89 | 9.73 | 0.12 | 0 | No | No |
132 | C_LAUNDRYROOMFLR1_1_1_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 11.89 | 9.73 | 0.12 | 0 | No | No |
133 | P_ELEVATORCOREFLR1_10011_0_10009 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 1.83 | 2.99 | 0.00 | 0 | No | No |
134 | P_ELEVATORCOREFLR1_10012_0_10010 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 1.83 | 2.99 | 0.00 | 0 | No | No |
135 | P_ELEVATORCOREFLR1_10075_0_10050 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 1.83 | 2.99 | 0.00 | 0 | No | No |
136 | W_ELEVATORCOREFLR1_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 1.83 | 2.99 | 0.00 | 0 | No | No |
137 | S_ELEVATORCOREFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 1.83 | 2.99 | 0.00 | 0 | No | No |
138 | C_ELEVATORCOREFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 1.83 | 2.99 | 0.00 | 0 | No | No |
139 | P_EXERCISECENTERFLR1_10013_0_10011 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
140 | P_EXERCISECENTERFLR1_10014_0_10012 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
141 | W_EXERCISECENTERFLR1_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 3 | No | No |
142 | W_EXERCISECENTERFLR1_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 2 | No | No |
143 | P_EXERCISECENTERFLR1_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
144 | S_EXERCISECENTERFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
145 | C_EXERCISECENTERFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 3.96 | 5.35 | 0.12 | 0 | No | No |
146 | P_FRONTOFFICEFLR1_10015_0_10013 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 15.85 | 10.83 | 0.12 | 0 | No | No |
147 | P_FRONTOFFICEFLR1_10083_0_10053 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 15.85 | 10.83 | 0.12 | 0 | No | No |
148 | W_FRONTOFFICEFLR1_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 15.85 | 10.83 | 0.12 | 3 | No | No |
149 | W_FRONTOFFICEFLR1_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 15.85 | 10.83 | 0.12 | 2 | No | No |
150 | W_FRONTOFFICEFLR1_3_0_0_0_1 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 15.85 | 10.83 | 0.12 | 2 | No | No |
151 | W_FRONTOFFICEFLR1_3_0_0_0_2 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 15.85 | 10.83 | 0.12 | 2 | No | No |
152 | W_FRONTOFFICEFLR1_3_0_0_0_3 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 15.85 | 10.83 | 0.12 | 2 | No | No |
153 | P_FRONTOFFICEFLR1_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 15.85 | 10.83 | 0.12 | 0 | No | No |
154 | S_FRONTOFFICEFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 15.85 | 10.83 | 0.12 | 0 | No | No |
155 | C_FRONTOFFICEFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 15.85 | 10.83 | 0.12 | 0 | No | No |
156 | C_FRONTOFFICEFLR1_1_1_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 15.85 | 10.83 | 0.12 | 0 | No | No |
157 | P_FRONTSTAIRSFLR1_10017_0_10015 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
158 | P_FRONTSTAIRSFLR1_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
159 | W_FRONTSTAIRSFLR1_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
160 | W_FRONTSTAIRSFLR1_3_0_0_DOOR | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
161 | W_FRONTSTAIRSFLR1_4_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
162 | S_FRONTSTAIRSFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
163 | C_FRONTSTAIRSFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 10.67 | 3.76 | 0.00 | 0 | No | No |
164 | P_FRONTSTORAGEFLR1_10016_0_10014 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 1.52 | 2.57 | 0.00 | 0 | No | No |
165 | P_FRONTSTORAGEFLR1_10088_0_10056 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 1.52 | 2.57 | 0.00 | 0 | No | No |
166 | P_FRONTSTORAGEFLR1_10091_0_10058 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 1.52 | 2.57 | 0.00 | 0 | No | No |
167 | W_FRONTSTORAGEFLR1_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 3.35 | 1.52 | 2.57 | 0.00 | 0 | No | No |
168 | S_FRONTSTORAGEFLR1_0_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 1.52 | 2.57 | 0.00 | 0 | No | No |
169 | C_FRONTSTORAGEFLR1_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.35 | 1.52 | 2.57 | 0.00 | 0 | No | No |
170 | W_REARSTAIRSFLR2_2_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
171 | W_REARSTAIRSFLR2_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
172 | P_REARSTAIRSFLR2_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
173 | P_REARSTAIRSFLR2_5_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
174 | F_REARSTAIRSFLR2_10001_0_10000 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
175 | C_REARSTAIRSFLR2_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
176 | P_CORRIDORFLR2_10100_0_10062 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
177 | W_CORRIDORFLR2_2_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 3 | No | No |
178 | W_CORRIDORFLR2_2_0_0_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 2 | No | No |
179 | P_CORRIDORFLR2_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
180 | P_CORRIDORFLR2_5_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
181 | P_CORRIDORFLR2_6_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
182 | P_CORRIDORFLR2_7_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
183 | P_CORRIDORFLR2_8_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
184 | W_CORRIDORFLR2_9_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 4 | No | No |
185 | P_CORRIDORFLR2_10_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
186 | P_CORRIDORFLR2_11_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
187 | P_CORRIDORFLR2_12_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
188 | P_CORRIDORFLR2_13_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
189 | P_CORRIDORFLR2_14_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
190 | W_CORRIDORFLR2_15_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 3 | No | No |
191 | W_CORRIDORFLR2_15_0_0_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 2 | No | No |
192 | P_CORRIDORFLR2_16_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
193 | P_CORRIDORFLR2_17_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
194 | P_CORRIDORFLR2_18_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
195 | P_CORRIDORFLR2_19_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
196 | P_CORRIDORFLR2_20_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
197 | P_CORRIDORFLR2_21_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
198 | F_CORRIDORFLR2_10004_0_10003 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
199 | C_CORRIDORFLR2_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
200 | P_REARSTORAGEFLR2_10119_0_10079 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
201 | W_REARSTORAGEFLR2_2_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
202 | P_REARSTORAGEFLR2_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
203 | W_REARSTORAGEFLR2_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
204 | F_REARSTORAGEFLR2_10028_0_10026 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
205 | C_REARSTORAGEFLR2_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
206 | P_GUESTROOM201_10114_0_10074 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 0 | No | No |
207 | P_GUESTROOM201_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 0 | No | No |
208 | W_GUESTROOM201_4_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 4 | No | No |
209 | W_GUESTROOM201_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 4 | No | No |
210 | W_GUESTROOM201_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 1 | No | No |
211 | F_GUESTROOM201_10031_0_10028 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 0 | No | No |
212 | C_GUESTROOM201_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 0 | No | No |
213 | P_GUESTROOM202_205_10115_0_10075 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
214 | P_GUESTROOM202_205_10126_0_10083 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
215 | P_GUESTROOM202_205_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
216 | W_GUESTROOM202_205_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 4 | No | No |
217 | W_GUESTROOM202_205_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
218 | W_GUESTROOM202_205_5_0_0_0_1 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
219 | W_GUESTROOM202_205_5_0_0_0_2 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
220 | W_GUESTROOM202_205_5_0_0_0_3 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
221 | F_GUESTROOM202_205_10032_0_10029 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
222 | C_GUESTROOM202_205_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
223 | P_GUESTROOM206_208_10116_0_10076 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
224 | P_GUESTROOM206_208_10130_0_10085 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
225 | P_GUESTROOM206_208_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
226 | W_GUESTROOM206_208_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 3 | No | No |
227 | W_GUESTROOM206_208_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 2 | No | No |
228 | W_GUESTROOM206_208_5_0_0_0_1 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 2 | No | No |
229 | W_GUESTROOM206_208_5_0_0_0_2 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 2 | No | No |
230 | F_GUESTROOM206_208_10005_0_10004 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
231 | F_GUESTROOM206_208_10035_0_10031 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
232 | F_GUESTROOM206_208_10039_0_10032 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
233 | C_GUESTROOM206_208_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
234 | P_GUESTROOM209_212_10117_0_10077 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
235 | P_GUESTROOM209_212_10137_0_10087 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
236 | P_GUESTROOM209_212_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
237 | W_GUESTROOM209_212_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 3 | No | No |
238 | W_GUESTROOM209_212_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
239 | W_GUESTROOM209_212_5_0_0_0_1 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
240 | W_GUESTROOM209_212_5_0_0_0_2 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
241 | W_GUESTROOM209_212_5_0_0_0_3 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
242 | F_GUESTROOM209_212_10040_0_10033 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
243 | F_GUESTROOM209_212_10044_0_10035 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
244 | F_GUESTROOM209_212_10048_0_10037 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
245 | F_GUESTROOM209_212_10052_0_10039 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
246 | C_GUESTROOM209_212_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
247 | P_GUESTROOM213_10118_0_10078 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
248 | P_GUESTROOM213_10123_0_10081 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
249 | P_GUESTROOM213_10145_0_10089 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
250 | W_GUESTROOM213_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 4 | No | No |
251 | W_GUESTROOM213_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 1 | No | No |
252 | F_GUESTROOM213_10056_0_10041 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
253 | C_GUESTROOM213_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
254 | P_GUESTROOM214_10099_0_10061 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
255 | P_GUESTROOM214_10104_0_10064 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
256 | W_GUESTROOM214_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 4 | No | No |
257 | W_GUESTROOM214_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 1 | No | No |
258 | P_GUESTROOM214_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
259 | F_GUESTROOM214_10060_0_10042 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
260 | C_GUESTROOM214_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
261 | P_GUESTROOM215_218_10105_0_10065 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
262 | P_GUESTROOM215_218_10156_0_10092 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
263 | W_GUESTROOM215_218_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 3 | No | No |
264 | W_GUESTROOM215_218_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
265 | W_GUESTROOM215_218_3_0_0_0_1 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
266 | W_GUESTROOM215_218_3_0_0_0_2 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
267 | W_GUESTROOM215_218_3_0_0_0_3 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
268 | P_GUESTROOM215_218_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
269 | F_GUESTROOM215_218_10064_0_10044 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
270 | F_GUESTROOM215_218_10068_0_10046 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
271 | F_GUESTROOM215_218_10072_0_10048 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
272 | C_GUESTROOM215_218_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
273 | P_ELEVATORCOREFLR2_10107_0_10067 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
274 | P_ELEVATORCOREFLR2_10108_0_10068 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
275 | P_ELEVATORCOREFLR2_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
276 | W_ELEVATORCOREFLR2_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
277 | F_ELEVATORCOREFLR2_10077_0_10051 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
278 | C_ELEVATORCOREFLR2_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
279 | P_GUESTROOM219_10106_0_10066 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
280 | P_GUESTROOM219_10163_0_10094 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
281 | P_GUESTROOM219_10167_0_10096 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
282 | W_GUESTROOM219_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 3 | No | No |
283 | W_GUESTROOM219_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 2 | No | No |
284 | F_GUESTROOM219_10073_0_10049 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
285 | C_GUESTROOM219_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
286 | P_GUESTROOM220_223_10109_0_10069 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
287 | P_GUESTROOM220_223_10110_0_10070 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
288 | W_GUESTROOM220_223_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 4 | No | No |
289 | W_GUESTROOM220_223_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
290 | W_GUESTROOM220_223_3_0_0_0_1 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
291 | W_GUESTROOM220_223_3_0_0_0_2 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
292 | W_GUESTROOM220_223_3_0_0_0_3 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
293 | P_GUESTROOM220_223_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
294 | F_GUESTROOM220_223_10081_0_10052 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
295 | F_GUESTROOM220_223_10085_0_10054 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
296 | C_GUESTROOM220_223_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
297 | P_GUESTROOM224_10111_0_10071 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
298 | P_GUESTROOM224_10179_0_10099 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
299 | W_GUESTROOM224_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 3 | No | No |
300 | W_GUESTROOM224_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 2 | No | No |
301 | P_GUESTROOM224_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
302 | F_GUESTROOM224_10086_0_10055 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
303 | C_GUESTROOM224_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
304 | P_FRONTSTORAGEFLR2_10112_0_10072 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
305 | P_FRONTSTORAGEFLR2_10184_0_10101 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
306 | W_FRONTSTORAGEFLR2_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
307 | P_FRONTSTORAGEFLR2_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
308 | F_FRONTSTORAGEFLR2_10093_0_10059 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
309 | C_FRONTSTORAGEFLR2_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
310 | P_FRONTSTAIRSFLR2_10113_0_10073 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
311 | P_FRONTSTAIRSFLR2_10189_0_10103 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
312 | W_FRONTSTAIRSFLR2_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
313 | W_FRONTSTAIRSFLR2_4_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
314 | F_FRONTSTAIRSFLR2_10090_0_10057 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
315 | C_FRONTSTAIRSFLR2_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
316 | W_REARSTAIRSFLR3_2_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
317 | W_REARSTAIRSFLR3_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
318 | P_REARSTAIRSFLR3_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
319 | P_REARSTAIRSFLR3_5_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
320 | F_REARSTAIRSFLR3_10098_0_10060 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
321 | C_REARSTAIRSFLR3_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
322 | P_CORRIDORFLR3_10198_0_10107 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
323 | W_CORRIDORFLR3_2_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 3 | No | No |
324 | W_CORRIDORFLR3_2_0_0_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 2 | No | No |
325 | P_CORRIDORFLR3_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
326 | P_CORRIDORFLR3_5_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
327 | P_CORRIDORFLR3_6_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
328 | P_CORRIDORFLR3_7_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
329 | P_CORRIDORFLR3_8_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
330 | W_CORRIDORFLR3_9_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 3 | No | No |
331 | P_CORRIDORFLR3_10_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
332 | P_CORRIDORFLR3_11_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
333 | P_CORRIDORFLR3_12_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
334 | P_CORRIDORFLR3_13_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
335 | P_CORRIDORFLR3_14_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
336 | W_CORRIDORFLR3_15_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 3 | No | No |
337 | W_CORRIDORFLR3_15_0_0_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 2 | No | No |
338 | P_CORRIDORFLR3_16_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
339 | P_CORRIDORFLR3_17_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
340 | P_CORRIDORFLR3_18_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
341 | P_CORRIDORFLR3_19_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
342 | P_CORRIDORFLR3_20_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
343 | P_CORRIDORFLR3_21_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
344 | F_CORRIDORFLR3_10102_0_10063 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
345 | C_CORRIDORFLR3_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
346 | P_REARSTORAGEFLR3_10217_0_10124 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
347 | W_REARSTORAGEFLR3_2_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
348 | P_REARSTORAGEFLR3_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
349 | W_REARSTORAGEFLR3_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
350 | F_REARSTORAGEFLR3_10121_0_10080 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
351 | C_REARSTORAGEFLR3_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
352 | P_GUESTROOM301_10212_0_10119 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 0 | No | No |
353 | P_GUESTROOM301_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 0 | No | No |
354 | W_GUESTROOM301_4_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 4 | No | No |
355 | W_GUESTROOM301_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 3 | No | No |
356 | W_GUESTROOM301_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 2 | No | No |
357 | F_GUESTROOM301_10125_0_10082 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 0 | No | No |
358 | C_GUESTROOM301_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 0 | No | No |
359 | P_GUESTROOM302_305_10213_0_10120 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
360 | P_GUESTROOM302_305_10224_0_10128 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
361 | P_GUESTROOM302_305_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
362 | W_GUESTROOM302_305_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 4 | No | No |
363 | W_GUESTROOM302_305_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
364 | W_GUESTROOM302_305_5_0_0_0_1 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
365 | W_GUESTROOM302_305_5_0_0_0_2 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
366 | W_GUESTROOM302_305_5_0_0_0_3 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
367 | F_GUESTROOM302_305_10129_0_10084 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
368 | C_GUESTROOM302_305_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
369 | P_GUESTROOM306_308_10214_0_10121 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
370 | P_GUESTROOM306_308_10228_0_10130 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
371 | P_GUESTROOM306_308_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
372 | W_GUESTROOM306_308_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 3 | No | No |
373 | W_GUESTROOM306_308_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 2 | No | No |
374 | W_GUESTROOM306_308_5_0_0_0_1 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 1 | No | No |
375 | W_GUESTROOM306_308_5_0_0_0_2 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 2 | No | No |
376 | F_GUESTROOM306_308_10136_0_10086 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
377 | C_GUESTROOM306_308_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
378 | P_GUESTROOM309_312_10215_0_10122 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
379 | P_GUESTROOM309_312_10233_0_10132 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
380 | P_GUESTROOM309_312_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
381 | W_GUESTROOM309_312_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 3 | No | No |
382 | W_GUESTROOM309_312_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
383 | W_GUESTROOM309_312_5_0_0_0_1 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
384 | W_GUESTROOM309_312_5_0_0_0_2 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
385 | W_GUESTROOM309_312_5_0_0_0_3 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
386 | F_GUESTROOM309_312_10144_0_10088 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
387 | C_GUESTROOM309_312_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
388 | P_GUESTROOM313_10216_0_10123 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
389 | P_GUESTROOM313_10221_0_10126 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
390 | P_GUESTROOM313_10238_0_10134 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
391 | W_GUESTROOM313_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 3 | No | No |
392 | W_GUESTROOM313_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 2 | No | No |
393 | F_GUESTROOM313_10149_0_10090 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
394 | C_GUESTROOM313_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
395 | P_GUESTROOM314_10197_0_10106 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
396 | P_GUESTROOM314_10202_0_10109 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
397 | W_GUESTROOM314_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 3 | No | No |
398 | W_GUESTROOM314_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 2 | No | No |
399 | P_GUESTROOM314_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
400 | F_GUESTROOM314_10154_0_10091 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
401 | C_GUESTROOM314_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
402 | P_GUESTROOM315_318_10203_0_10110 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
403 | P_GUESTROOM315_318_10249_0_10137 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
404 | W_GUESTROOM315_318_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 3 | No | No |
405 | W_GUESTROOM315_318_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
406 | W_GUESTROOM315_318_3_0_0_0_1 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
407 | W_GUESTROOM315_318_3_0_0_0_2 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
408 | W_GUESTROOM315_318_3_0_0_0_3 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
409 | P_GUESTROOM315_318_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
410 | F_GUESTROOM315_318_10161_0_10093 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
411 | C_GUESTROOM315_318_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
412 | P_ELEVATORCOREFLR3_10205_0_10112 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
413 | P_ELEVATORCOREFLR3_10206_0_10113 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
414 | P_ELEVATORCOREFLR3_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
415 | W_ELEVATORCOREFLR3_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
416 | F_ELEVATORCOREFLR3_10166_0_10095 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
417 | C_ELEVATORCOREFLR3_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
418 | P_GUESTROOM319_10204_0_10111 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
419 | P_GUESTROOM319_10254_0_10139 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
420 | P_GUESTROOM319_10258_0_10141 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
421 | W_GUESTROOM319_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 3 | No | No |
422 | W_GUESTROOM319_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 2 | No | No |
423 | F_GUESTROOM319_10171_0_10097 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
424 | C_GUESTROOM319_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
425 | P_GUESTROOM320_323_10207_0_10114 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
426 | P_GUESTROOM320_323_10208_0_10115 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
427 | W_GUESTROOM320_323_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 4 | No | No |
428 | W_GUESTROOM320_323_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
429 | W_GUESTROOM320_323_3_0_0_0_1 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
430 | W_GUESTROOM320_323_3_0_0_0_2 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 2 | No | No |
431 | W_GUESTROOM320_323_3_0_0_0_3 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
432 | P_GUESTROOM320_323_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
433 | F_GUESTROOM320_323_10177_0_10098 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
434 | C_GUESTROOM320_323_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
435 | P_GUESTROOM324_10209_0_10116 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
436 | P_GUESTROOM324_10269_0_10144 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
437 | W_GUESTROOM324_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 3 | No | No |
438 | W_GUESTROOM324_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 2 | No | No |
439 | P_GUESTROOM324_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
440 | F_GUESTROOM324_10182_0_10100 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
441 | C_GUESTROOM324_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
442 | P_FRONTSTORAGEFLR3_10210_0_10117 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
443 | P_FRONTSTORAGEFLR3_10274_0_10146 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
444 | W_FRONTSTORAGEFLR3_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
445 | P_FRONTSTORAGEFLR3_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
446 | F_FRONTSTORAGEFLR3_10187_0_10102 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
447 | C_FRONTSTORAGEFLR3_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
448 | P_FRONTSTAIRSFLR3_10211_0_10118 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
449 | P_FRONTSTAIRSFLR3_10279_0_10148 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
450 | W_FRONTSTAIRSFLR3_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
451 | W_FRONTSTAIRSFLR3_4_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
452 | F_FRONTSTAIRSFLR3_10192_0_10104 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
453 | C_FRONTSTAIRSFLR3_1_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
454 | W_REARSTAIRSFLR4_2_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
455 | W_REARSTAIRSFLR4_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
456 | P_REARSTAIRSFLR4_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
457 | P_REARSTAIRSFLR4_5_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
458 | F_REARSTAIRSFLR4_10196_0_10105 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
459 | R_REARSTAIRSFLR4_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
460 | P_CORRIDORFLR4_10287_0_10151 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
461 | W_CORRIDORFLR4_2_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 3 | No | No |
462 | W_CORRIDORFLR4_2_0_0_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 2 | No | No |
463 | P_CORRIDORFLR4_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
464 | P_CORRIDORFLR4_5_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
465 | P_CORRIDORFLR4_6_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
466 | P_CORRIDORFLR4_7_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
467 | P_CORRIDORFLR4_8_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
468 | W_CORRIDORFLR4_9_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 3 | No | No |
469 | P_CORRIDORFLR4_10_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
470 | P_CORRIDORFLR4_11_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
471 | P_CORRIDORFLR4_12_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
472 | P_CORRIDORFLR4_13_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
473 | P_CORRIDORFLR4_14_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
474 | W_CORRIDORFLR4_15_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 3 | No | No |
475 | W_CORRIDORFLR4_15_0_0_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 2 | No | No |
476 | P_CORRIDORFLR4_16_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
477 | P_CORRIDORFLR4_17_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
478 | P_CORRIDORFLR4_18_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
479 | P_CORRIDORFLR4_19_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
480 | P_CORRIDORFLR4_20_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
481 | P_CORRIDORFLR4_21_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
482 | F_CORRIDORFLR4_10200_0_10108 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
483 | R_CORRIDORFLR4_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 6.71 | 3.86 | 0.14 | 0 | No | No |
484 | P_REARSTORAGEFLR4_10305_0_10167 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
485 | W_REARSTORAGEFLR4_2_0_0 | 0 | 211.83 | 138.95 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
486 | P_REARSTORAGEFLR4_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
487 | W_REARSTORAGEFLR4_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
488 | F_REARSTORAGEFLR4_10219_0_10125 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
489 | R_REARSTORAGEFLR4_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
490 | P_GUESTROOM401_10300_0_10162 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 0 | No | No |
491 | P_GUESTROOM401_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 0 | No | No |
492 | W_GUESTROOM401_4_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 3 | No | No |
493 | W_GUESTROOM401_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 3 | No | No |
494 | W_GUESTROOM401_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 1 | No | No |
495 | F_GUESTROOM401_10223_0_10127 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 0 | No | No |
496 | R_GUESTROOM401_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 12.19 | 5.35 | 4.92E-002 | 0 | No | No |
497 | P_GUESTROOM402_405_10301_0_10163 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
498 | P_GUESTROOM402_405_10310_0_10169 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
499 | P_GUESTROOM402_405_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
500 | W_GUESTROOM402_405_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 3 | No | No |
501 | W_GUESTROOM402_405_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
502 | W_GUESTROOM402_405_5_0_0_0_1 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
503 | W_GUESTROOM402_405_5_0_0_0_2 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
504 | W_GUESTROOM402_405_5_0_0_0_3 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
505 | F_GUESTROOM402_405_10227_0_10129 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
506 | R_GUESTROOM402_405_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
507 | P_GUESTROOM406_408_10302_0_10164 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
508 | P_GUESTROOM406_408_10313_0_10170 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
509 | P_GUESTROOM406_408_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
510 | W_GUESTROOM406_408_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 3 | No | No |
511 | W_GUESTROOM406_408_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 1 | No | No |
512 | W_GUESTROOM406_408_5_0_0_0_1 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 1 | No | No |
513 | W_GUESTROOM406_408_5_0_0_0_2 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 1 | No | No |
514 | F_GUESTROOM406_408_10232_0_10131 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
515 | R_GUESTROOM406_408_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 12.80 | 10.02 | 0.19 | 0 | No | No |
516 | P_GUESTROOM409_412_10303_0_10165 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
517 | P_GUESTROOM409_412_10317_0_10171 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
518 | P_GUESTROOM409_412_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
519 | W_GUESTROOM409_412_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 3 | No | No |
520 | W_GUESTROOM409_412_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
521 | W_GUESTROOM409_412_5_0_0_0_1 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
522 | W_GUESTROOM409_412_5_0_0_0_2 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
523 | W_GUESTROOM409_412_5_0_0_0_3 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
524 | F_GUESTROOM409_412_10237_0_10133 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
525 | R_GUESTROOM409_412_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
526 | P_GUESTROOM413_10304_0_10166 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
527 | P_GUESTROOM413_10308_0_10168 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
528 | P_GUESTROOM413_10321_0_10172 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
529 | W_GUESTROOM413_5_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 4 | No | No |
530 | W_GUESTROOM413_5_0_0_0_0 | 0 | 635.46 | 132.99 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 1 | No | No |
531 | F_GUESTROOM413_10242_0_10135 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
532 | R_GUESTROOM413_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
533 | P_GUESTROOM414_10286_0_10150 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
534 | P_GUESTROOM414_10290_0_10152 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
535 | W_GUESTROOM414_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 4 | No | No |
536 | W_GUESTROOM414_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 1 | No | No |
537 | P_GUESTROOM414_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
538 | F_GUESTROOM414_10247_0_10136 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
539 | R_GUESTROOM414_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
540 | P_GUESTROOM415_418_10291_0_10153 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
541 | P_GUESTROOM415_418_10330_0_10173 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
542 | W_GUESTROOM415_418_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 4 | No | No |
543 | W_GUESTROOM415_418_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
544 | W_GUESTROOM415_418_3_0_0_0_1 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
545 | W_GUESTROOM415_418_3_0_0_0_2 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
546 | W_GUESTROOM415_418_3_0_0_0_3 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
547 | P_GUESTROOM415_418_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
548 | F_GUESTROOM415_418_10252_0_10138 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
549 | R_GUESTROOM415_418_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
550 | P_ELEVATORCOREFLR4_10293_0_10155 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
551 | P_ELEVATORCOREFLR4_10294_0_10156 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
552 | P_ELEVATORCOREFLR4_2_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
553 | W_ELEVATORCOREFLR4_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
554 | F_ELEVATORCOREFLR4_10257_0_10140 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
555 | R_ELEVATORCOREFLR4_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 1.83 | 2.99 | 0.00 | 0 | No | No |
556 | P_GUESTROOM419_10292_0_10154 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
557 | P_GUESTROOM419_10334_0_10174 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
558 | P_GUESTROOM419_10337_0_10175 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
559 | W_GUESTROOM419_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 4 | No | No |
560 | W_GUESTROOM419_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 1 | No | No |
561 | F_GUESTROOM419_10262_0_10142 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
562 | R_GUESTROOM419_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
563 | P_GUESTROOM420_423_10295_0_10157 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
564 | P_GUESTROOM420_423_10296_0_10158 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
565 | W_GUESTROOM420_423_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 3 | No | No |
566 | W_GUESTROOM420_423_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
567 | W_GUESTROOM420_423_3_0_0_0_1 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
568 | W_GUESTROOM420_423_3_0_0_0_2 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
569 | W_GUESTROOM420_423_3_0_0_0_3 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 1 | No | No |
570 | P_GUESTROOM420_423_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
571 | F_GUESTROOM420_423_10267_0_10143 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
572 | R_GUESTROOM420_423_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 15.85 | 10.83 | 0.15 | 0 | No | No |
573 | P_GUESTROOM424_10297_0_10159 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
574 | P_GUESTROOM424_10346_0_10176 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
575 | W_GUESTROOM424_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 4 | No | No |
576 | W_GUESTROOM424_3_0_0_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 1 | No | No |
577 | P_GUESTROOM424_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
578 | F_GUESTROOM424_10272_0_10145 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
579 | R_GUESTROOM424_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 3.96 | 5.35 | 0.15 | 0 | No | No |
580 | P_FRONTSTORAGEFLR4_10298_0_10160 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
581 | P_FRONTSTORAGEFLR4_10350_0_10177 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
582 | W_FRONTSTORAGEFLR4_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
583 | P_FRONTSTORAGEFLR4_4_0_0 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
584 | F_FRONTSTORAGEFLR4_10277_0_10147 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
585 | R_FRONTSTORAGEFLR4_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 1.52 | 2.57 | 0.00 | 0 | No | No |
586 | P_FRONTSTAIRSFLR4_10299_0_10161 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
587 | P_FRONTSTAIRSFLR4_10354_0_10178 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
588 | W_FRONTSTAIRSFLR4_3_0_0 | 0 | 635.46 | 138.95 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
589 | W_FRONTSTAIRSFLR4_4_0_0 | 0 | 211.83 | 59.84 | 11.58 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
590 | F_FRONTSTAIRSFLR4_10282_0_10149 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
591 | R_FRONTSTAIRSFLR4_1_0_0 | 0 | 1003.40 | 167.12 | 0.00 | 0 | 2.74 | 10.67 | 3.76 | 0.00 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | CORRIDORFLR1_INFILTRATION | ALWAYSON | CORRIDORFLR1 | 150.51 | 0.0 | 1.972E-002 | 1.310E-004 | 5.690E-004 | 0.141 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | CORRIDORFLR1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | CORRIDORFLR1 | 150.51 | 0.0 | 0.916 | 6.083E-003 | 2.642E-002 | 6.532 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | CORRIDORFLR2_INFILTRATION | ALWAYSON | CORRIDORFLR2 | 125.42 | 0.0 | 1.047E-002 | 8.345E-005 | 5.690E-004 | 0.110 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | CORRIDORFLR3_INFILTRATION | ALWAYSON | CORRIDORFLR3 | 125.42 | 0.0 | 1.047E-002 | 8.345E-005 | 5.690E-004 | 0.110 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | CORRIDORFLR4_INFILTRATION | ALWAYSON | CORRIDORFLR4 | 125.42 | 0.0 | 1.047E-002 | 8.344E-005 | 7.277E-005 | 0.110 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | ELEVATORCOREFLR1_INFILTRATION | ALWAYSON | ELEVATORCOREFLR1 | 15.05 | 0.0 | 3.489E-003 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
7 | ELEVATORCOREFLR2_INFILTRATION | ALWAYSON | ELEVATORCOREFLR2 | 15.05 | 0.0 | 2.854E-003 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | ELEVATORCOREFLR3_INFILTRATION | ALWAYSON | ELEVATORCOREFLR3 | 15.05 | 0.0 | 2.854E-003 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
9 | ELEVATORCOREFLR4_INFILTRATION | ALWAYSON | ELEVATORCOREFLR4 | 15.05 | 0.0 | 2.855E-003 | 1.897E-004 | 1.423E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | EMPLOYEELOUNGEFLR1_INFILTRATION | COMMONAREA_INFIL_SCH | EMPLOYEELOUNGEFLR1 | 32.61 | 18.0 | 7.559E-003 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
11 | EXERCISECENTERFLR1_INFILTRATION | COMMONAREA_INFIL_SCH | EXERCISECENTERFLR1 | 32.61 | 7.0 | 7.559E-003 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | FRONTLOUNGEFLR1_INFILTRATION | COMMONAREA_INFIL_SCH | FRONTLOUNGEFLR1 | 163.06 | 53.0 | 5.349E-002 | 3.281E-004 | 5.690E-004 | 0.352 | 0.000 | 0.000 | 0.224 | 0.000 |
13 | FRONTOFFICEFLR1_INFILTRATION | COMMONAREA_INFIL_SCH | FRONTOFFICEFLR1 | 130.44 | 10.0 | 3.023E-002 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | FRONTSTAIRSFLR1_INFILTRATION | ALWAYSON | FRONTSTAIRSFLR1 | 20.07 | 0.0 | 2.146E-002 | 1.069E-003 | 5.690E-004 | 1.148 | 0.000 | 0.000 | 0.224 | 0.000 |
15 | FRONTSTAIRSFLR2_INFILTRATION | ALWAYSON | FRONTSTAIRSFLR2 | 20.07 | 0.0 | 1.665E-002 | 8.297E-004 | 5.690E-004 | 1.089 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | FRONTSTAIRSFLR3_INFILTRATION | ALWAYSON | FRONTSTAIRSFLR3 | 20.07 | 0.0 | 1.665E-002 | 8.297E-004 | 5.690E-004 | 1.089 | 0.000 | 0.000 | 0.224 | 0.000 |
17 | FRONTSTAIRSFLR4_INFILTRATION | ALWAYSON | FRONTSTAIRSFLR4 | 20.07 | 0.0 | 1.665E-002 | 8.296E-004 | 3.375E-004 | 1.089 | 0.000 | 0.000 | 0.224 | 0.000 |
18 | FRONTSTORAGEFLR1_INFILTRATION | ALWAYSON | FRONTSTORAGEFLR1 | 12.54 | 0.0 | 2.907E-003 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
19 | FRONTSTORAGEFLR2_INFILTRATION | ALWAYSON | FRONTSTORAGEFLR2 | 12.54 | 0.0 | 2.379E-003 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
20 | FRONTSTORAGEFLR3_INFILTRATION | ALWAYSON | FRONTSTORAGEFLR3 | 12.54 | 0.0 | 2.379E-003 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
21 | FRONTSTORAGEFLR4_INFILTRATION | ALWAYSON | FRONTSTORAGEFLR4 | 12.54 | 0.0 | 2.379E-003 | 1.897E-004 | 1.422E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
22 | GUESTROOM101_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM101 | 32.61 | 1.5 | 7.559E-003 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
23 | GUESTROOM102_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM102 | 32.61 | 1.5 | 7.559E-003 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
24 | GUESTROOM103_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM103 | 32.61 | 1.5 | 7.559E-003 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
25 | GUESTROOM104_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM104 | 32.61 | 1.5 | 7.559E-003 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
26 | GUESTROOM105_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM105 | 32.61 | 1.5 | 7.559E-003 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
27 | GUESTROOM201_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM201 | 32.61 | 1.5 | 1.903E-002 | 5.835E-004 | 5.690E-004 | 0.766 | 0.000 | 0.000 | 0.224 | 0.000 |
28 | GUESTROOM202_205_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM202_205 | 130.45 | 6.0 | 2.474E-002 | 1.896E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
29 | GUESTROOM206_208_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM206_208 | 105.36 | 4.5 | 1.998E-002 | 1.896E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
30 | GUESTROOM209_212_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM209_212 | 130.45 | 6.0 | 2.474E-002 | 1.896E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
31 | GUESTROOM213_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM213 | 32.61 | 1.5 | 6.184E-003 | 1.896E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
32 | GUESTROOM214_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM214 | 32.61 | 1.5 | 6.184E-003 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
33 | GUESTROOM215_218_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM215_218 | 130.44 | 6.0 | 2.474E-002 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
34 | GUESTROOM219_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM219 | 32.61 | 1.5 | 6.184E-003 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
35 | GUESTROOM220_223_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM220_223 | 130.44 | 6.0 | 2.474E-002 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
36 | GUESTROOM224_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM224 | 32.61 | 1.5 | 6.184E-003 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
37 | GUESTROOM301_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM301 | 32.61 | 1.5 | 1.903E-002 | 5.835E-004 | 5.690E-004 | 0.766 | 0.000 | 0.000 | 0.224 | 0.000 |
38 | GUESTROOM302_305_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM302_305 | 130.45 | 6.0 | 2.474E-002 | 1.896E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
39 | GUESTROOM306_308_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM306_308 | 105.36 | 4.5 | 1.998E-002 | 1.896E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
40 | GUESTROOM309_312_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM309_312 | 130.45 | 6.0 | 2.474E-002 | 1.896E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
41 | GUESTROOM313_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM313 | 32.61 | 1.5 | 6.184E-003 | 1.896E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
42 | GUESTROOM314_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM314 | 32.61 | 1.5 | 6.184E-003 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
43 | GUESTROOM315_318_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM315_318 | 130.44 | 6.0 | 2.474E-002 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
44 | GUESTROOM319_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM319 | 32.61 | 1.5 | 6.184E-003 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
45 | GUESTROOM320_323_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM320_323 | 130.44 | 6.0 | 2.474E-002 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
46 | GUESTROOM324_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM324 | 32.61 | 1.5 | 6.184E-003 | 1.897E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
47 | GUESTROOM401_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM401 | 32.61 | 1.5 | 1.903E-002 | 5.836E-004 | 2.881E-004 | 0.766 | 0.000 | 0.000 | 0.224 | 0.000 |
48 | GUESTROOM402_405_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM402_405 | 130.45 | 6.0 | 2.474E-002 | 1.896E-004 | 1.422E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
49 | GUESTROOM406_408_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM406_408 | 105.36 | 4.5 | 1.998E-002 | 1.896E-004 | 1.422E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
50 | GUESTROOM409_412_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM409_412 | 130.45 | 6.0 | 2.474E-002 | 1.896E-004 | 1.422E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
51 | GUESTROOM413_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM413 | 32.61 | 1.5 | 6.185E-003 | 1.896E-004 | 1.422E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
52 | GUESTROOM414_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM414 | 32.61 | 1.5 | 6.184E-003 | 1.897E-004 | 1.422E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
53 | GUESTROOM415_418_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM415_418 | 130.44 | 6.0 | 2.474E-002 | 1.897E-004 | 1.422E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
54 | GUESTROOM419_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM419 | 32.61 | 1.5 | 6.184E-003 | 1.897E-004 | 1.422E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
55 | GUESTROOM420_423_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM420_423 | 130.44 | 6.0 | 2.474E-002 | 1.897E-004 | 1.422E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
56 | GUESTROOM424_INFILTRATION | GUESTROOM_INFIL_SCH | GUESTROOM424 | 32.61 | 1.5 | 6.184E-003 | 1.897E-004 | 1.422E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
57 | LAUNDRYROOMFLR1_INFILTRATION | GUESTROOM_INFIL_SCH | LAUNDRYROOMFLR1 | 97.83 | 11.0 | 2.268E-002 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
58 | MECHANICALROOMFLR1_INFILTRATION | GUESTROOM_INFIL_SCH | MECHANICALROOMFLR1 | 32.61 | 0.0 | 7.559E-003 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
59 | MEETINGROOMFLR1_INFILTRATION | GUESTROOM_INFIL_SCH | MEETINGROOMFLR1 | 80.27 | 43.0 | 1.861E-002 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
60 | REARSTAIRSFLR1_INFILTRATION | ALWAYSON | REARSTAIRSFLR1 | 20.07 | 0.0 | 2.146E-002 | 1.069E-003 | 5.690E-004 | 1.148 | 0.000 | 0.000 | 0.224 | 0.000 |
61 | REARSTAIRSFLR2_INFILTRATION | ALWAYSON | REARSTAIRSFLR2 | 20.07 | 0.0 | 1.665E-002 | 8.296E-004 | 5.690E-004 | 1.089 | 0.000 | 0.000 | 0.224 | 0.000 |
62 | REARSTAIRSFLR3_INFILTRATION | ALWAYSON | REARSTAIRSFLR3 | 20.07 | 0.0 | 1.665E-002 | 8.296E-004 | 5.690E-004 | 1.089 | 0.000 | 0.000 | 0.224 | 0.000 |
63 | REARSTAIRSFLR4_INFILTRATION | ALWAYSON | REARSTAIRSFLR4 | 20.07 | 0.0 | 1.665E-002 | 8.296E-004 | 3.375E-004 | 1.089 | 0.000 | 0.000 | 0.224 | 0.000 |
64 | REARSTORAGEFLR1_INFILTRATION | ALWAYSON | REARSTORAGEFLR1 | 20.07 | 0.0 | 2.035E-002 | 1.014E-003 | 5.690E-004 | 1.089 | 0.000 | 0.000 | 0.224 | 0.000 |
65 | REARSTORAGEFLR2_INFILTRATION | ALWAYSON | REARSTORAGEFLR2 | 20.07 | 0.0 | 1.665E-002 | 8.296E-004 | 5.690E-004 | 1.089 | 0.000 | 0.000 | 0.224 | 0.000 |
66 | REARSTORAGEFLR3_INFILTRATION | ALWAYSON | REARSTORAGEFLR3 | 20.07 | 0.0 | 1.665E-002 | 8.296E-004 | 5.690E-004 | 1.089 | 0.000 | 0.000 | 0.224 | 0.000 |
67 | REARSTORAGEFLR4_INFILTRATION | ALWAYSON | REARSTORAGEFLR4 | 20.07 | 0.0 | 1.665E-002 | 8.296E-004 | 3.375E-004 | 1.089 | 0.000 | 0.000 | 0.224 | 0.000 |
68 | RESTROOMFLR1_INFILTRATION | COMMONAREA_INFIL_SCH | RESTROOMFLR1 | 32.61 | 1.0 | 7.559E-003 | 2.318E-004 | 5.690E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
1 | GUESTROOM103 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM103 | 32.61 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
2 | GUESTROOM202_205 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM202_205 | 130.45 | 6.0 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
3 | GUESTROOM206_208 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM206_208 | 105.36 | 4.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
4 | GUESTROOM209_212 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM209_212 | 130.45 | 6.0 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
5 | GUESTROOM213 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM213 | 32.61 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
6 | GUESTROOM309_312 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM309_312 | 130.45 | 6.0 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
7 | GUESTROOM401 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM401 | 32.61 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
8 | GUESTROOM409_412 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM409_412 | 130.45 | 6.0 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
9 | GUESTROOM104 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM104 | 32.61 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
10 | GUESTROOM105 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM105 | 32.61 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
11 | GUESTROOM214 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM214 | 32.61 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
12 | GUESTROOM219 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM219 | 32.61 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
13 | GUESTROOM220_223 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM220_223 | 130.44 | 6.0 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
14 | GUESTROOM224 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM224 | 32.61 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
15 | GUESTROOM314 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM314 | 32.61 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
16 | GUESTROOM315_318 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM315_318 | 130.44 | 6.0 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
17 | GUESTROOM320_323 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM320_323 | 130.44 | 6.0 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
18 | GUESTROOM415_418 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM415_418 | 130.44 | 6.0 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
19 | GUESTROOM419 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM419 | 32.61 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
20 | GUESTROOM420_423 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM420_423 | 130.44 | 6.0 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
21 | GUESTROOM424 SLIDING DOOR VENTILATION | Constant-0.0 | GUESTROOM424 | 32.61 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | REARSTAIRSFLR1 | Mixing/Well-Stirred |
2 | CORRIDORFLR1 | Mixing/Well-Stirred |
3 | REARSTORAGEFLR1 | Mixing/Well-Stirred |
4 | FRONTLOUNGEFLR1 | Mixing/Well-Stirred |
5 | RESTROOMFLR1 | Mixing/Well-Stirred |
6 | MEETINGROOMFLR1 | Mixing/Well-Stirred |
7 | MECHANICALROOMFLR1 | Mixing/Well-Stirred |
8 | GUESTROOM101 | Mixing/Well-Stirred |
9 | GUESTROOM102 | Mixing/Well-Stirred |
10 | GUESTROOM103 | Mixing/Well-Stirred |
11 | GUESTROOM104 | Mixing/Well-Stirred |
12 | GUESTROOM105 | Mixing/Well-Stirred |
13 | EMPLOYEELOUNGEFLR1 | Mixing/Well-Stirred |
14 | LAUNDRYROOMFLR1 | Mixing/Well-Stirred |
15 | ELEVATORCOREFLR1 | Mixing/Well-Stirred |
16 | EXERCISECENTERFLR1 | Mixing/Well-Stirred |
17 | FRONTOFFICEFLR1 | Mixing/Well-Stirred |
18 | FRONTSTAIRSFLR1 | Mixing/Well-Stirred |
19 | FRONTSTORAGEFLR1 | Mixing/Well-Stirred |
20 | REARSTAIRSFLR2 | Mixing/Well-Stirred |
21 | CORRIDORFLR2 | Mixing/Well-Stirred |
22 | REARSTORAGEFLR2 | Mixing/Well-Stirred |
23 | GUESTROOM201 | Mixing/Well-Stirred |
24 | GUESTROOM202_205 | Mixing/Well-Stirred |
25 | GUESTROOM206_208 | Mixing/Well-Stirred |
26 | GUESTROOM209_212 | Mixing/Well-Stirred |
27 | GUESTROOM213 | Mixing/Well-Stirred |
28 | GUESTROOM214 | Mixing/Well-Stirred |
29 | GUESTROOM215_218 | Mixing/Well-Stirred |
30 | ELEVATORCOREFLR2 | Mixing/Well-Stirred |
31 | GUESTROOM219 | Mixing/Well-Stirred |
32 | GUESTROOM220_223 | Mixing/Well-Stirred |
33 | GUESTROOM224 | Mixing/Well-Stirred |
34 | FRONTSTORAGEFLR2 | Mixing/Well-Stirred |
35 | FRONTSTAIRSFLR2 | Mixing/Well-Stirred |
36 | REARSTAIRSFLR3 | Mixing/Well-Stirred |
37 | CORRIDORFLR3 | Mixing/Well-Stirred |
38 | REARSTORAGEFLR3 | Mixing/Well-Stirred |
39 | GUESTROOM301 | Mixing/Well-Stirred |
40 | GUESTROOM302_305 | Mixing/Well-Stirred |
41 | GUESTROOM306_308 | Mixing/Well-Stirred |
42 | GUESTROOM309_312 | Mixing/Well-Stirred |
43 | GUESTROOM313 | Mixing/Well-Stirred |
44 | GUESTROOM314 | Mixing/Well-Stirred |
45 | GUESTROOM315_318 | Mixing/Well-Stirred |
46 | ELEVATORCOREFLR3 | Mixing/Well-Stirred |
47 | GUESTROOM319 | Mixing/Well-Stirred |
48 | GUESTROOM320_323 | Mixing/Well-Stirred |
49 | GUESTROOM324 | Mixing/Well-Stirred |
50 | FRONTSTORAGEFLR3 | Mixing/Well-Stirred |
51 | FRONTSTAIRSFLR3 | Mixing/Well-Stirred |
52 | REARSTAIRSFLR4 | Mixing/Well-Stirred |
53 | CORRIDORFLR4 | Mixing/Well-Stirred |
54 | REARSTORAGEFLR4 | Mixing/Well-Stirred |
55 | GUESTROOM401 | Mixing/Well-Stirred |
56 | GUESTROOM402_405 | Mixing/Well-Stirred |
57 | GUESTROOM406_408 | Mixing/Well-Stirred |
58 | GUESTROOM409_412 | Mixing/Well-Stirred |
59 | GUESTROOM413 | Mixing/Well-Stirred |
60 | GUESTROOM414 | Mixing/Well-Stirred |
61 | GUESTROOM415_418 | Mixing/Well-Stirred |
62 | ELEVATORCOREFLR4 | Mixing/Well-Stirred |
63 | GUESTROOM419 | Mixing/Well-Stirred |
64 | GUESTROOM420_423 | Mixing/Well-Stirred |
65 | GUESTROOM424 | Mixing/Well-Stirred |
66 | FRONTSTORAGEFLR4 | Mixing/Well-Stirred |
67 | FRONTSTAIRSFLR4 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone REARSTAIRSFLR1 | 1.2000 |
3 | Zone CORRIDORFLR1 | 1.2000 |
4 | Zone FRONTLOUNGEFLR1 | 1.2000 |
5 | Zone RESTROOMFLR1 | 1.2000 |
6 | Zone MEETINGROOMFLR1 | 1.2000 |
7 | Zone MECHANICALROOMFLR1 | 1.2000 |
8 | Zone GUESTROOM101 | 1.2000 |
9 | Zone GUESTROOM102 | 1.2000 |
10 | Zone GUESTROOM103 | 1.2000 |
11 | Zone GUESTROOM104 | 1.2000 |
12 | Zone GUESTROOM105 | 1.2000 |
13 | Zone EMPLOYEELOUNGEFLR1 | 1.2000 |
14 | Zone EXERCISECENTERFLR1 | 1.2000 |
15 | Zone FRONTOFFICEFLR1 | 1.2000 |
16 | Zone FRONTSTAIRSFLR1 | 1.2000 |
17 | Zone REARSTAIRSFLR2 | 1.2000 |
18 | Zone CORRIDORFLR2 | 1.2000 |
19 | Zone GUESTROOM201 | 1.2000 |
20 | Zone GUESTROOM202_205 | 1.2000 |
21 | Zone GUESTROOM206_208 | 1.2000 |
22 | Zone GUESTROOM209_212 | 1.2000 |
23 | Zone GUESTROOM213 | 1.2000 |
24 | Zone GUESTROOM214 | 1.2000 |
25 | Zone GUESTROOM215_218 | 1.2000 |
26 | Zone GUESTROOM219 | 1.2000 |
27 | Zone GUESTROOM220_223 | 1.2000 |
28 | Zone GUESTROOM224 | 1.2000 |
29 | Zone FRONTSTAIRSFLR2 | 1.2000 |
30 | Zone REARSTAIRSFLR3 | 1.2000 |
31 | Zone CORRIDORFLR3 | 1.2000 |
32 | Zone GUESTROOM301 | 1.2000 |
33 | Zone GUESTROOM302_305 | 1.2000 |
34 | Zone GUESTROOM306_308 | 1.2000 |
35 | Zone GUESTROOM309_312 | 1.2000 |
36 | Zone GUESTROOM313 | 1.2000 |
37 | Zone GUESTROOM314 | 1.2000 |
38 | Zone GUESTROOM315_318 | 1.2000 |
39 | Zone GUESTROOM319 | 1.2000 |
40 | Zone GUESTROOM320_323 | 1.2000 |
41 | Zone GUESTROOM324 | 1.2000 |
42 | Zone FRONTSTAIRSFLR3 | 1.2000 |
43 | Zone REARSTAIRSFLR4 | 1.2000 |
44 | Zone CORRIDORFLR4 | 1.2000 |
45 | Zone GUESTROOM401 | 1.2000 |
46 | Zone GUESTROOM402_405 | 1.2000 |
47 | Zone GUESTROOM406_408 | 1.2000 |
48 | Zone GUESTROOM409_412 | 1.2000 |
49 | Zone GUESTROOM413 | 1.2000 |
50 | Zone GUESTROOM414 | 1.2000 |
51 | Zone GUESTROOM415_418 | 1.2000 |
52 | Zone GUESTROOM419 | 1.2000 |
53 | Zone GUESTROOM420_423 | 1.2000 |
54 | Zone GUESTROOM424 | 1.2000 |
55 | Zone FRONTSTAIRSFLR4 | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone REARSTAIRSFLR1 | 1.2000 |
3 | Zone CORRIDORFLR1 | 1.2000 |
4 | Zone FRONTLOUNGEFLR1 | 1.2000 |
5 | Zone RESTROOMFLR1 | 1.2000 |
6 | Zone MEETINGROOMFLR1 | 1.2000 |
7 | Zone MECHANICALROOMFLR1 | 1.2000 |
8 | Zone GUESTROOM101 | 1.2000 |
9 | Zone GUESTROOM102 | 1.2000 |
10 | Zone GUESTROOM103 | 1.2000 |
11 | Zone GUESTROOM104 | 1.2000 |
12 | Zone GUESTROOM105 | 1.2000 |
13 | Zone EMPLOYEELOUNGEFLR1 | 1.2000 |
14 | Zone EXERCISECENTERFLR1 | 1.2000 |
15 | Zone FRONTOFFICEFLR1 | 1.2000 |
16 | Zone FRONTSTAIRSFLR1 | 1.2000 |
17 | Zone REARSTAIRSFLR2 | 1.2000 |
18 | Zone CORRIDORFLR2 | 1.2000 |
19 | Zone GUESTROOM201 | 1.2000 |
20 | Zone GUESTROOM202_205 | 1.2000 |
21 | Zone GUESTROOM206_208 | 1.2000 |
22 | Zone GUESTROOM209_212 | 1.2000 |
23 | Zone GUESTROOM213 | 1.2000 |
24 | Zone GUESTROOM214 | 1.2000 |
25 | Zone GUESTROOM215_218 | 1.2000 |
26 | Zone GUESTROOM219 | 1.2000 |
27 | Zone GUESTROOM220_223 | 1.2000 |
28 | Zone GUESTROOM224 | 1.2000 |
29 | Zone FRONTSTAIRSFLR2 | 1.2000 |
30 | Zone REARSTAIRSFLR3 | 1.2000 |
31 | Zone CORRIDORFLR3 | 1.2000 |
32 | Zone GUESTROOM301 | 1.2000 |
33 | Zone GUESTROOM302_305 | 1.2000 |
34 | Zone GUESTROOM306_308 | 1.2000 |
35 | Zone GUESTROOM309_312 | 1.2000 |
36 | Zone GUESTROOM313 | 1.2000 |
37 | Zone GUESTROOM314 | 1.2000 |
38 | Zone GUESTROOM315_318 | 1.2000 |
39 | Zone GUESTROOM319 | 1.2000 |
40 | Zone GUESTROOM320_323 | 1.2000 |
41 | Zone GUESTROOM324 | 1.2000 |
42 | Zone FRONTSTAIRSFLR3 | 1.2000 |
43 | Zone REARSTAIRSFLR4 | 1.2000 |
44 | Zone CORRIDORFLR4 | 1.2000 |
45 | Zone GUESTROOM401 | 1.2000 |
46 | Zone GUESTROOM402_405 | 1.2000 |
47 | Zone GUESTROOM406_408 | 1.2000 |
48 | Zone GUESTROOM409_412 | 1.2000 |
49 | Zone GUESTROOM413 | 1.2000 |
50 | Zone GUESTROOM414 | 1.2000 |
51 | Zone GUESTROOM415_418 | 1.2000 |
52 | Zone GUESTROOM419 | 1.2000 |
53 | Zone GUESTROOM420_423 | 1.2000 |
54 | Zone GUESTROOM424 | 1.2000 |
55 | Zone FRONTSTAIRSFLR4 | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | REARSTAIRSFLR1 | Cooling | 0.00000 | 0.00000 | 0.00000 | 6.11554E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 40.80000 | 5.57864E-003 | 20.07186 | 0.00000 | 6.11554E-003 | 0.00000 | |
2 | REARSTAIRSFLR1 | Heating | 0.00000 | 0.00000 | 0.00000 | 6.11554E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 0.50000 | 4.31558E-003 | 20.07186 | 0.00000 | 6.11554E-003 | 0.00000 | |
3 | CORRIDORFLR1 | Cooling | 32240.45863 | 38688.55036 | 2.92330 | 3.50797 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 37.60800 | 5.57864E-003 | 150.50577 | 0.00000 | 4.58564E-002 | 0.00000 |
4 | CORRIDORFLR1 | Heating | 22396.66334 | 26875.99601 | 0.69496 | 0.83395 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 150.50577 | 0.00000 | 4.58564E-002 | 0.00000 |
5 | FRONTLOUNGEFLR1 | Cooling | 8977.40650 | 10772.88780 | 0.81500 | 0.97800 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 40.53400 | 5.57865E-003 | 163.05641 | 53.00000 | 0.23598 | 0.00000 |
6 | FRONTLOUNGEFLR1 | Heating | 984.64305 | 1181.57166 | 3.05754E-002 | 0.23598 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 07:20:00 | 0.50000 | 4.31558E-003 | 163.05641 | 53.00000 | 0.23598 | 0.00000 |
7 | RESTROOMFLR1 | Cooling | 768.19120 | 921.82944 | 6.96883E-002 | 8.36260E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:20:00 | 39.64733 | 5.57864E-003 | 32.61128 | 1.00000 | 0.00000 | 0.00000 |
8 | RESTROOMFLR1 | Heating | 40.64964 | 48.77957 | 1.26226E-003 | 1.51471E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 07:30:00 | 0.50000 | 4.31558E-003 | 32.61128 | 1.00000 | 0.00000 | 0.00000 |
9 | MEETINGROOMFLR1 | Cooling | 4283.93035 | 5140.71642 | 0.38911 | 0.46693 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 40.80000 | 5.57864E-003 | 80.27392 | 43.00000 | 0.12637 | 0.00000 |
10 | MEETINGROOMFLR1 | Heating | 275.47894 | 330.57473 | 8.55424E-003 | 0.12637 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 07:00:00 | 0.50000 | 4.31558E-003 | 80.27392 | 43.00000 | 0.12637 | 0.00000 |
11 | GUESTROOM101 | Cooling | 856.74163 | 1028.08996 | 0.10808 | 0.12969 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:50:00 | 40.13500 | 5.57864E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
12 | GUESTROOM101 | Heating | 102.03121 | 122.43745 | 3.16830E-003 | 1.34741E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 07:50:00 | 0.50000 | 4.31558E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
13 | GUESTROOM102 | Cooling | 665.55054 | 798.66065 | 8.39583E-002 | 0.10075 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:50:00 | 40.13500 | 5.57864E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
14 | GUESTROOM102 | Heating | 159.25126 | 191.10152 | 4.94511E-003 | 1.34741E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 07:30:00 | 0.50000 | 4.31558E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
15 | GUESTROOM103 | Cooling | 1326.98097 | 1592.37716 | 0.16741 | 0.20089 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:10:00 | 37.27550 | 5.57864E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
16 | GUESTROOM103 | Heating | 304.52444 | 365.42933 | 9.45616E-003 | 1.34741E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 07:40:00 | 0.50000 | 4.31558E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
17 | GUESTROOM104 | Cooling | 1439.98192 | 1727.97830 | 0.18167 | 0.21800 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 39.47000 | 5.57864E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
18 | GUESTROOM104 | Heating | 289.54619 | 347.45542 | 8.99106E-003 | 1.34731E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:10:00 | 0.50000 | 4.31558E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
19 | GUESTROOM105 | Cooling | 1920.56411 | 2304.67694 | 0.24230 | 0.29075 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.57864E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
20 | GUESTROOM105 | Heating | 152.11527 | 182.53832 | 4.72352E-003 | 1.34731E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:30:00 | 0.50000 | 4.31558E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
21 | EMPLOYEELOUNGEFLR1 | Cooling | 8063.52745 | 9676.23294 | 0.73219 | 0.87862 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.57864E-003 | 32.60897 | 18.00000 | 5.13328E-002 | 0.00000 |
22 | EMPLOYEELOUNGEFLR1 | Heating | 92.28918 | 110.74702 | 2.86578E-003 | 5.13328E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:10:00 | 0.50000 | 4.31558E-003 | 32.60897 | 18.00000 | 5.13328E-002 | 0.00000 |
23 | EXERCISECENTERFLR1 | Cooling | 1606.59145 | 1927.90974 | 0.14581 | 0.17497 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 38.93800 | 5.57864E-003 | 32.60897 | 7.00000 | 4.30533E-002 | 0.00000 |
24 | EXERCISECENTERFLR1 | Heating | 0.00000 | 0.00000 | 0.00000 | 4.30533E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 0.50000 | 4.31558E-003 | 32.60897 | 7.00000 | 4.30533E-002 | 0.00000 | |
25 | FRONTOFFICEFLR1 | Cooling | 3966.92088 | 4760.30505 | 0.35991 | 0.43189 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.57864E-003 | 130.43587 | 10.00000 | 5.63004E-002 | 0.00000 |
26 | FRONTOFFICEFLR1 | Heating | 573.37706 | 688.05247 | 1.78046E-002 | 5.63004E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 06:20:00 | 0.50000 | 4.31558E-003 | 130.43587 | 10.00000 | 5.63004E-002 | 0.00000 |
27 | FRONTSTAIRSFLR1 | Cooling | 0.00000 | 0.00000 | 0.00000 | 6.11407E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 40.80000 | 5.57864E-003 | 20.06706 | 0.00000 | 6.11407E-003 | 0.00000 | |
28 | FRONTSTAIRSFLR1 | Heating | 0.00000 | 0.00000 | 0.00000 | 6.11407E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 0.50000 | 4.31558E-003 | 20.06706 | 0.00000 | 6.11407E-003 | 0.00000 | |
29 | REARSTAIRSFLR2 | Cooling | 0.00000 | 0.00000 | 0.00000 | 6.11554E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 40.80000 | 5.57864E-003 | 20.07186 | 0.00000 | 6.11554E-003 | 0.00000 | |
30 | REARSTAIRSFLR2 | Heating | 0.00000 | 0.00000 | 0.00000 | 6.11554E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 0.50000 | 4.31558E-003 | 20.07186 | 0.00000 | 6.11554E-003 | 0.00000 | |
31 | CORRIDORFLR2 | Cooling | 3009.46086 | 3611.35303 | 0.27300 | 0.32759 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:50:00 | 39.11533 | 5.57865E-003 | 125.42017 | 0.00000 | 3.82133E-002 | 0.00000 |
32 | CORRIDORFLR2 | Heating | 358.76044 | 430.51253 | 1.11402E-002 | 3.82133E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:30:00 | 0.50000 | 4.31558E-003 | 125.42017 | 0.00000 | 3.82133E-002 | 0.00000 |
33 | GUESTROOM201 | Cooling | 971.15326 | 1165.38392 | 0.12250 | 0.14700 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 40.46750 | 5.57865E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
34 | GUESTROOM201 | Heating | 280.16246 | 336.19495 | 8.69967E-003 | 1.34741E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:40:00 | 0.50000 | 4.31558E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
35 | GUESTROOM202_205 | Cooling | 4141.44434 | 4969.73321 | 0.52249 | 0.62699 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.57864E-003 | 130.44512 | 6.00000 | 5.38964E-002 | 0.00000 |
36 | GUESTROOM202_205 | Heating | 593.09126 | 711.70951 | 1.84168E-002 | 5.38964E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:10:00 | 0.50000 | 4.31558E-003 | 130.44512 | 6.00000 | 5.38964E-002 | 0.00000 |
37 | GUESTROOM206_208 | Cooling | 3389.67614 | 4067.61136 | 0.42764 | 0.51317 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.57864E-003 | 105.35952 | 4.50000 | 4.27148E-002 | 0.00000 |
38 | GUESTROOM206_208 | Heating | 442.15848 | 530.59018 | 1.37300E-002 | 4.27148E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 0.50000 | 4.31558E-003 | 105.35952 | 4.50000 | 4.27148E-002 | 0.00000 |
39 | GUESTROOM209_212 | Cooling | 3950.55446 | 4740.66536 | 0.49840 | 0.59809 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.57864E-003 | 130.44512 | 6.00000 | 5.38964E-002 | 0.00000 |
40 | GUESTROOM209_212 | Heating | 498.79420 | 598.55304 | 1.54887E-002 | 5.38964E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:20:00 | 0.50000 | 4.31558E-003 | 130.44512 | 6.00000 | 5.38964E-002 | 0.00000 |
41 | GUESTROOM213 | Cooling | 1150.77093 | 1380.92512 | 0.14518 | 0.17422 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 37.60800 | 5.57864E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
42 | GUESTROOM213 | Heating | 300.72993 | 360.87592 | 9.33834E-003 | 1.34741E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 0.50000 | 4.31558E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
43 | GUESTROOM214 | Cooling | 1364.84204 | 1637.81044 | 0.17219 | 0.20663 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 39.47000 | 5.57864E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
44 | GUESTROOM214 | Heating | 273.61381 | 328.33657 | 8.49632E-003 | 1.34731E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 10:40:00 | 0.50000 | 4.31558E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
45 | GUESTROOM215_218 | Cooling | 13293.30950 | 15951.97140 | 1.67692 | 2.01231 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.57864E-003 | 130.43587 | 6.00000 | 5.38926E-002 | 0.00000 |
46 | GUESTROOM215_218 | Heating | 422.04785 | 506.45742 | 1.31055E-002 | 5.38926E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:10:00 | 0.50000 | 4.31558E-003 | 130.43587 | 6.00000 | 5.38926E-002 | 0.00000 |
47 | GUESTROOM219 | Cooling | 7404.15218 | 8884.98261 | 0.93409 | 1.12091 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.57864E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
48 | GUESTROOM219 | Heating | 62.44399 | 74.93279 | 1.93903E-003 | 1.34731E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 0.50000 | 4.31558E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
49 | GUESTROOM220_223 | Cooling | 4286.15224 | 5143.38269 | 0.54074 | 0.64889 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 40.40100 | 5.57864E-003 | 130.43587 | 6.00000 | 5.38926E-002 | 0.00000 |
50 | GUESTROOM220_223 | Heating | 480.12298 | 576.14757 | 1.49089E-002 | 5.38926E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 130.43587 | 6.00000 | 5.38926E-002 | 0.00000 |
51 | GUESTROOM224 | Cooling | 1271.21248 | 1525.45497 | 0.16038 | 0.19245 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.57864E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
52 | GUESTROOM224 | Heating | 238.51956 | 286.22347 | 7.40656E-003 | 1.34731E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:30:00 | 0.50000 | 4.31558E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
53 | FRONTSTAIRSFLR2 | Cooling | 0.00000 | 0.00000 | 0.00000 | 6.11407E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 40.80000 | 5.57864E-003 | 20.06706 | 0.00000 | 6.11407E-003 | 0.00000 | |
54 | FRONTSTAIRSFLR2 | Heating | 0.00000 | 0.00000 | 0.00000 | 6.11407E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 0.50000 | 4.31558E-003 | 20.06706 | 0.00000 | 6.11407E-003 | 0.00000 | |
55 | REARSTAIRSFLR3 | Cooling | 0.00000 | 0.00000 | 0.00000 | 6.11554E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 40.80000 | 5.57864E-003 | 20.07186 | 0.00000 | 6.11554E-003 | 0.00000 | |
56 | REARSTAIRSFLR3 | Heating | 0.00000 | 0.00000 | 0.00000 | 6.11554E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 0.50000 | 4.31558E-003 | 20.07186 | 0.00000 | 6.11554E-003 | 0.00000 | |
57 | CORRIDORFLR3 | Cooling | 980.53466 | 1176.64159 | 8.89464E-002 | 0.10674 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 38.93800 | 5.57864E-003 | 125.42017 | 0.00000 | 3.82133E-002 | 0.00000 |
58 | CORRIDORFLR3 | Heating | 565.63223 | 678.75868 | 1.75639E-002 | 3.82133E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 17:10:00 | 0.50000 | 4.31558E-003 | 125.42017 | 0.00000 | 3.82133E-002 | 0.00000 |
59 | GUESTROOM301 | Cooling | 771.67739 | 926.01286 | 9.73385E-002 | 0.11681 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 40.80000 | 5.57864E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
60 | GUESTROOM301 | Heating | 306.66216 | 367.99459 | 9.52254E-003 | 1.34741E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 23:40:00 | 0.50000 | 4.31558E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
61 | GUESTROOM302_305 | Cooling | 1658.22208 | 1989.86650 | 0.20918 | 0.25102 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:50:00 | 40.13500 | 5.57864E-003 | 130.44512 | 6.00000 | 5.38964E-002 | 0.00000 |
62 | GUESTROOM302_305 | Heating | 671.49473 | 805.79368 | 2.08514E-002 | 5.38964E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 0.50000 | 4.31558E-003 | 130.44512 | 6.00000 | 5.38964E-002 | 0.00000 |
63 | GUESTROOM306_308 | Cooling | 1428.44384 | 1714.13261 | 0.18019 | 0.21623 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:50:00 | 40.13500 | 5.57864E-003 | 105.35952 | 4.50000 | 4.27148E-002 | 0.00000 |
64 | GUESTROOM306_308 | Heating | 564.10741 | 676.92889 | 1.75168E-002 | 4.27148E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 16:10:00 | 0.50000 | 4.31558E-003 | 105.35952 | 4.50000 | 4.27148E-002 | 0.00000 |
65 | GUESTROOM309_312 | Cooling | 3684.07632 | 4420.89158 | 0.46478 | 0.55774 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:00:00 | 40.00200 | 5.57864E-003 | 130.44512 | 6.00000 | 5.38964E-002 | 0.00000 |
66 | GUESTROOM309_312 | Heating | 658.23297 | 789.87957 | 2.04396E-002 | 5.38964E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 0.50000 | 4.31558E-003 | 130.44512 | 6.00000 | 5.38964E-002 | 0.00000 |
67 | GUESTROOM313 | Cooling | 668.03410 | 801.64092 | 8.42708E-002 | 0.10112 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:10:00 | 37.27550 | 5.57864E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
68 | GUESTROOM313 | Heating | 342.86189 | 411.43427 | 1.06466E-002 | 1.34741E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 0.50000 | 4.31558E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
69 | GUESTROOM314 | Cooling | 1195.89385 | 1435.07262 | 0.15087 | 0.18105 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | 39.29267 | 5.57865E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
70 | GUESTROOM314 | Heating | 314.20584 | 377.04701 | 9.75679E-003 | 1.34731E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 18:00:00 | 0.50000 | 4.31558E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
71 | GUESTROOM315_318 | Cooling | 4922.80279 | 5907.36335 | 0.62106 | 0.74527 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.57864E-003 | 130.43587 | 6.00000 | 5.38926E-002 | 0.00000 |
72 | GUESTROOM315_318 | Heating | 631.96466 | 758.35759 | 1.96239E-002 | 5.38926E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 13:30:00 | 0.50000 | 4.31558E-003 | 130.43587 | 6.00000 | 5.38926E-002 | 0.00000 |
73 | GUESTROOM319 | Cooling | 1226.79955 | 1472.15946 | 0.15476 | 0.18571 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:50:00 | 40.13500 | 5.57864E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
74 | GUESTROOM319 | Heating | 163.28035 | 195.93642 | 5.07022E-003 | 1.34731E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 13:40:00 | 0.50000 | 4.31558E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
75 | GUESTROOM320_323 | Cooling | 3868.47001 | 4642.16401 | 0.48805 | 0.58566 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.57864E-003 | 130.43587 | 6.00000 | 5.38926E-002 | 0.00000 |
76 | GUESTROOM320_323 | Heating | 631.54375 | 757.85251 | 1.96108E-002 | 5.38926E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 14:40:00 | 0.50000 | 4.31558E-003 | 130.43587 | 6.00000 | 5.38926E-002 | 0.00000 |
77 | GUESTROOM324 | Cooling | 704.50562 | 845.40674 | 8.88716E-002 | 0.10665 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:50:00 | 40.13500 | 5.57864E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
78 | GUESTROOM324 | Heating | 285.27495 | 342.32994 | 8.85842E-003 | 1.34731E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 0.50000 | 4.31558E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
79 | FRONTSTAIRSFLR3 | Cooling | 0.00000 | 0.00000 | 0.00000 | 6.11407E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 40.80000 | 5.57864E-003 | 20.06706 | 0.00000 | 6.11407E-003 | 0.00000 | |
80 | FRONTSTAIRSFLR3 | Heating | 0.00000 | 0.00000 | 0.00000 | 6.11407E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 0.50000 | 4.31558E-003 | 20.06706 | 0.00000 | 6.11407E-003 | 0.00000 | |
81 | REARSTAIRSFLR4 | Cooling | 0.00000 | 0.00000 | 0.00000 | 6.11554E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 40.80000 | 5.57864E-003 | 20.07186 | 0.00000 | 6.11554E-003 | 0.00000 | |
82 | REARSTAIRSFLR4 | Heating | 0.00000 | 0.00000 | 0.00000 | 6.11554E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 0.50000 | 4.31558E-003 | 20.07186 | 0.00000 | 6.11554E-003 | 0.00000 | |
83 | CORRIDORFLR4 | Cooling | 1464.58290 | 1757.49948 | 0.13286 | 0.15943 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.57864E-003 | 125.42017 | 0.00000 | 3.82133E-002 | 0.00000 |
84 | CORRIDORFLR4 | Heating | 1155.30498 | 1386.36597 | 3.58744E-002 | 4.30493E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 23:30:00 | 0.50000 | 4.31558E-003 | 125.42017 | 0.00000 | 3.82133E-002 | 0.00000 |
85 | GUESTROOM401 | Cooling | 1484.41338 | 1781.29606 | 0.18726 | 0.22471 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 40.68917 | 5.57864E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
86 | GUESTROOM401 | Heating | 429.63701 | 515.56441 | 1.33412E-002 | 1.60094E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 23:40:00 | 0.50000 | 4.31558E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
87 | GUESTROOM402_405 | Cooling | 2217.97775 | 2661.57330 | 0.27979 | 0.33575 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 40.80000 | 5.57864E-003 | 130.44512 | 6.00000 | 5.38964E-002 | 0.00000 |
88 | GUESTROOM402_405 | Heating | 1103.94433 | 1324.73319 | 3.42799E-002 | 5.38964E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 23:40:00 | 0.50000 | 4.31558E-003 | 130.44512 | 6.00000 | 5.38964E-002 | 0.00000 |
89 | GUESTROOM406_408 | Cooling | 1884.28186 | 2261.13823 | 0.23770 | 0.28523 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 40.80000 | 5.57864E-003 | 105.35952 | 4.50000 | 4.27148E-002 | 0.00000 |
90 | GUESTROOM406_408 | Heating | 928.35493 | 1114.02591 | 2.88275E-002 | 4.27148E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 23:20:00 | 0.50000 | 4.31558E-003 | 105.35952 | 4.50000 | 4.27148E-002 | 0.00000 |
91 | GUESTROOM409_412 | Cooling | 4487.18318 | 5384.61982 | 0.56610 | 0.67932 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 40.80000 | 5.57864E-003 | 130.44512 | 6.00000 | 5.38964E-002 | 0.00000 |
92 | GUESTROOM409_412 | Heating | 1105.65932 | 1326.79118 | 3.43332E-002 | 5.38964E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 0.50000 | 4.31558E-003 | 130.44512 | 6.00000 | 5.38964E-002 | 0.00000 |
93 | GUESTROOM413 | Cooling | 876.84905 | 1052.21886 | 0.11061 | 0.13273 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.57864E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
94 | GUESTROOM413 | Heating | 485.99939 | 583.19927 | 1.50914E-002 | 1.81096E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 0.50000 | 4.31558E-003 | 32.61128 | 1.50000 | 1.34741E-002 | 0.00000 |
95 | GUESTROOM414 | Cooling | 947.97478 | 1137.56974 | 0.11958 | 0.14350 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 40.40100 | 5.57864E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
96 | GUESTROOM414 | Heating | 457.33879 | 548.80655 | 1.42014E-002 | 1.70417E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 0.50000 | 4.31558E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
97 | GUESTROOM415_418 | Cooling | 4839.11827 | 5806.94193 | 0.61050 | 0.73260 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 40.80000 | 5.57864E-003 | 130.43587 | 6.00000 | 5.38926E-002 | 0.00000 |
98 | GUESTROOM415_418 | Heating | 1092.57302 | 1311.08763 | 3.39268E-002 | 5.38926E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 17:50:00 | 0.50000 | 4.31558E-003 | 130.43587 | 6.00000 | 5.38926E-002 | 0.00000 |
99 | GUESTROOM419 | Cooling | 1366.50262 | 1639.80315 | 0.17240 | 0.20688 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 40.80000 | 5.57864E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
100 | GUESTROOM419 | Heating | 317.79229 | 381.35075 | 9.86816E-003 | 1.34731E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 18:50:00 | 0.50000 | 4.31558E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
101 | GUESTROOM420_423 | Cooling | 4713.91093 | 5656.69312 | 0.59471 | 0.71365 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 40.80000 | 5.57864E-003 | 130.43587 | 6.00000 | 5.38926E-002 | 0.00000 |
102 | GUESTROOM420_423 | Heating | 1078.73317 | 1294.47980 | 3.34971E-002 | 5.38926E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 19:20:00 | 0.50000 | 4.31558E-003 | 130.43587 | 6.00000 | 5.38926E-002 | 0.00000 |
103 | GUESTROOM424 | Cooling | 1393.22089 | 1671.86506 | 0.17577 | 0.21092 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 40.66700 | 5.57864E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
104 | GUESTROOM424 | Heating | 430.14314 | 516.17177 | 1.33569E-002 | 1.60283E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 0.50000 | 4.31558E-003 | 32.60897 | 1.50000 | 1.34731E-002 | 0.00000 |
105 | FRONTSTAIRSFLR4 | Cooling | 0.00000 | 0.00000 | 0.00000 | 6.11407E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 40.80000 | 5.57864E-003 | 20.06706 | 0.00000 | 6.11407E-003 | 0.00000 | |
106 | FRONTSTAIRSFLR4 | Heating | 0.00000 | 0.00000 | 0.00000 | 6.11407E-003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 0.50000 | 4.31558E-003 | 20.06706 | 0.00000 | 6.11407E-003 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | SAC_FRONTOFFICE | Cooling | Sensible | 6674.67 | 0.43189 | 0.43189 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | SAC_FRONTOFFICE | Heating | Sensible | 2442.93 | 5.63004E-002 | 5.63004E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
3 | SAC_FRONTLOUNGE | Cooling | Sensible | 17081.45 | 0.97800 | 0.97800 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | SAC_FRONTLOUNGE | Heating | Sensible | 10239.49 | 0.23598 | 0.23598 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
5 | SAC_MEETINGROOM | Cooling | Sensible | 8440.94 | 0.46693 | 0.46693 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
6 | SAC_MEETINGROOM | Heating | Sensible | 5483.17 | 0.12637 | 0.12637 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
7 | SAC_EXC_EMPLGE_RESTRM | Cooling | Sensible | 16515.13 | 1.13722 | 1.13722 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
8 | SAC_EXC_EMPLGE_RESTRM | Heating | Sensible | 4126.94 | 9.59008E-002 | 9.59008E-002 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 07:30:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | ZoneHVAC:UnitHeater | REARSTAIRSFLR1 UNITHEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 6.11554E-003 |
2 | Fan:ConstantVolume | REARSTAIRSFLR1UNITHEATERFAN | Design Size Maximum Flow Rate [m3/s] | 6.11554E-003 |
3 | Coil:Heating:Electric | REARSTAIRSFLR1UNITHEATERHEATINGCOIL | Design Size Nominal Capacity [W] | 291.77826 |
4 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR1 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 3.50797 |
5 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR1 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
6 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR1 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 3.50797 |
7 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR1 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
8 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR1 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 3.50797 |
9 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR1 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
10 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR1 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 4.58564E-002 |
11 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR1 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 4.58699E-002 |
12 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR1 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 4.58564E-002 |
13 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR1 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 4.58699E-002 |
14 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR1 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 4.58564E-002 |
15 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR1 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 4.58699E-002 |
16 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR1 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
17 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR1 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1851.63180 |
18 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR1 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
19 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR1 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
20 | Coil:Heating:Electric | CORRIDORFLR1 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 27932.60728 |
21 | Fan:OnOff | CORRIDORFLR1 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
22 | AirTerminal:SingleDuct:Uncontrolled | FRONTLOUNGEFLR1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.97800 |
23 | AirTerminal:SingleDuct:Uncontrolled | RESTROOMFLR1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 8.36260E-002 |
24 | AirTerminal:SingleDuct:Uncontrolled | MEETINGROOMFLR1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.46693 |
25 | ZoneHVAC:UnitHeater | MECHRM UNITHEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.00000 |
26 | Fan:ConstantVolume | MECHRMUNITHEATERFAN | Design Size Maximum Flow Rate [m3/s] | 0.00000 |
27 | Coil:Heating:Electric | MECHRMUNITHEATERHEATINGCOIL | Design Size Nominal Capacity [W] | 0.00000 |
28 | ZoneHVAC:PackagedTerminalAirConditioner | 101 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
29 | ZoneHVAC:PackagedTerminalAirConditioner | 101 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
30 | ZoneHVAC:PackagedTerminalAirConditioner | 101 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
31 | ZoneHVAC:PackagedTerminalAirConditioner | 101 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34741E-002 |
32 | ZoneHVAC:PackagedTerminalAirConditioner | 101 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
33 | ZoneHVAC:PackagedTerminalAirConditioner | 101 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34741E-002 |
34 | ZoneHVAC:PackagedTerminalAirConditioner | 101 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
35 | ZoneHVAC:PackagedTerminalAirConditioner | 101 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34741E-002 |
36 | ZoneHVAC:PackagedTerminalAirConditioner | 101 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
37 | Coil:Cooling:DX:SingleSpeed | 101 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
38 | Coil:Cooling:DX:SingleSpeed | 101 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1752.38472 |
39 | Coil:Cooling:DX:SingleSpeed | 101 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
40 | Coil:Cooling:DX:SingleSpeed | 101 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
41 | Coil:Heating:Electric | 101 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.49778 |
42 | Fan:OnOff | 101 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
43 | ZoneHVAC:PackagedTerminalAirConditioner | 102 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.10075 |
44 | ZoneHVAC:PackagedTerminalAirConditioner | 102 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
45 | ZoneHVAC:PackagedTerminalAirConditioner | 102 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.10075 |
46 | ZoneHVAC:PackagedTerminalAirConditioner | 102 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
47 | ZoneHVAC:PackagedTerminalAirConditioner | 102 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.10075 |
48 | ZoneHVAC:PackagedTerminalAirConditioner | 102 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
49 | ZoneHVAC:PackagedTerminalAirConditioner | 102 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34741E-002 |
50 | ZoneHVAC:PackagedTerminalAirConditioner | 102 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
51 | ZoneHVAC:PackagedTerminalAirConditioner | 102 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34741E-002 |
52 | ZoneHVAC:PackagedTerminalAirConditioner | 102 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
53 | ZoneHVAC:PackagedTerminalAirConditioner | 102 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34741E-002 |
54 | ZoneHVAC:PackagedTerminalAirConditioner | 102 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
55 | Coil:Cooling:DX:SingleSpeed | 102 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
56 | Coil:Cooling:DX:SingleSpeed | 102 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1843.34374 |
57 | Coil:Cooling:DX:SingleSpeed | 102 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
58 | Coil:Cooling:DX:SingleSpeed | 102 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
59 | Coil:Heating:Electric | 102 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.49778 |
60 | Fan:OnOff | 102 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
61 | ZoneHVAC:PackagedTerminalAirConditioner | 103 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.20089 |
62 | ZoneHVAC:PackagedTerminalAirConditioner | 103 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
63 | ZoneHVAC:PackagedTerminalAirConditioner | 103 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.20089 |
64 | ZoneHVAC:PackagedTerminalAirConditioner | 103 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
65 | ZoneHVAC:PackagedTerminalAirConditioner | 103 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.20089 |
66 | ZoneHVAC:PackagedTerminalAirConditioner | 103 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
67 | ZoneHVAC:PackagedTerminalAirConditioner | 103 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34741E-002 |
68 | ZoneHVAC:PackagedTerminalAirConditioner | 103 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
69 | ZoneHVAC:PackagedTerminalAirConditioner | 103 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34741E-002 |
70 | ZoneHVAC:PackagedTerminalAirConditioner | 103 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
71 | ZoneHVAC:PackagedTerminalAirConditioner | 103 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34741E-002 |
72 | ZoneHVAC:PackagedTerminalAirConditioner | 103 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
73 | Coil:Cooling:DX:SingleSpeed | 103 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
74 | Coil:Cooling:DX:SingleSpeed | 103 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1540.03421 |
75 | Coil:Cooling:DX:SingleSpeed | 103 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
76 | Coil:Cooling:DX:SingleSpeed | 103 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
77 | Coil:Heating:Electric | 103 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.49778 |
78 | Fan:OnOff | 103 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
79 | ZoneHVAC:PackagedTerminalAirConditioner | 104 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.21800 |
80 | ZoneHVAC:PackagedTerminalAirConditioner | 104 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
81 | ZoneHVAC:PackagedTerminalAirConditioner | 104 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.21800 |
82 | ZoneHVAC:PackagedTerminalAirConditioner | 104 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
83 | ZoneHVAC:PackagedTerminalAirConditioner | 104 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.21800 |
84 | ZoneHVAC:PackagedTerminalAirConditioner | 104 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
85 | ZoneHVAC:PackagedTerminalAirConditioner | 104 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34731E-002 |
86 | ZoneHVAC:PackagedTerminalAirConditioner | 104 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
87 | ZoneHVAC:PackagedTerminalAirConditioner | 104 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34731E-002 |
88 | ZoneHVAC:PackagedTerminalAirConditioner | 104 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
89 | ZoneHVAC:PackagedTerminalAirConditioner | 104 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34731E-002 |
90 | ZoneHVAC:PackagedTerminalAirConditioner | 104 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
91 | Coil:Cooling:DX:SingleSpeed | 104 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
92 | Coil:Cooling:DX:SingleSpeed | 104 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1593.94900 |
93 | Coil:Cooling:DX:SingleSpeed | 104 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
94 | Coil:Cooling:DX:SingleSpeed | 104 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
95 | Coil:Heating:Electric | 104 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.44502 |
96 | Fan:OnOff | 104 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
97 | ZoneHVAC:PackagedTerminalAirConditioner | 105 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.29075 |
98 | ZoneHVAC:PackagedTerminalAirConditioner | 105 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
99 | ZoneHVAC:PackagedTerminalAirConditioner | 105 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.29075 |
100 | ZoneHVAC:PackagedTerminalAirConditioner | 105 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
101 | ZoneHVAC:PackagedTerminalAirConditioner | 105 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.29075 |
102 | ZoneHVAC:PackagedTerminalAirConditioner | 105 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
103 | ZoneHVAC:PackagedTerminalAirConditioner | 105 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34731E-002 |
104 | ZoneHVAC:PackagedTerminalAirConditioner | 105 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
105 | ZoneHVAC:PackagedTerminalAirConditioner | 105 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34731E-002 |
106 | ZoneHVAC:PackagedTerminalAirConditioner | 105 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
107 | ZoneHVAC:PackagedTerminalAirConditioner | 105 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34731E-002 |
108 | ZoneHVAC:PackagedTerminalAirConditioner | 105 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
109 | Coil:Cooling:DX:SingleSpeed | 105 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
110 | Coil:Cooling:DX:SingleSpeed | 105 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1571.96754 |
111 | Coil:Cooling:DX:SingleSpeed | 105 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
112 | Coil:Cooling:DX:SingleSpeed | 105 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
113 | Coil:Heating:Electric | 105 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.44502 |
114 | Fan:OnOff | 105 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
115 | AirTerminal:SingleDuct:Uncontrolled | EMPLOYEELOUNGEFLR1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.87862 |
116 | AirTerminal:SingleDuct:Uncontrolled | EXERCISECENTERFLR1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.17497 |
117 | AirTerminal:SingleDuct:Uncontrolled | FRONTOFFICEFLR1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.43189 |
118 | ZoneHVAC:UnitHeater | FRONTSTAIRSFLR1 UNITHEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 6.11407E-003 |
119 | Fan:ConstantVolume | FRONTSTAIRSFLR1UNITHEATERFAN | Design Size Maximum Flow Rate [m3/s] | 6.11407E-003 |
120 | Coil:Heating:Electric | FRONTSTAIRSFLR1UNITHEATERHEATINGCOIL | Design Size Nominal Capacity [W] | 291.70840 |
121 | ZoneHVAC:UnitHeater | REARSTAIRSFLR2 UNITHEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 6.11554E-003 |
122 | Fan:ConstantVolume | REARSTAIRSFLR2UNITHEATERFAN | Design Size Maximum Flow Rate [m3/s] | 6.11554E-003 |
123 | Coil:Heating:Electric | REARSTAIRSFLR2UNITHEATERHEATINGCOIL | Design Size Nominal Capacity [W] | 291.77826 |
124 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR2 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.32759 |
125 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR2 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
126 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR2 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.32759 |
127 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR2 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
128 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR2 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.32759 |
129 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR2 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
130 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR2 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 3.82133E-002 |
131 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR2 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 3.82254E-002 |
132 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR2 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 3.82133E-002 |
133 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR2 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 3.82254E-002 |
134 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR2 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 3.82133E-002 |
135 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR2 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 3.82254E-002 |
136 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR2 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
137 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR2 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 2100.45125 |
138 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR2 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
139 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR2 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
140 | Coil:Heating:Electric | CORRIDORFLR2 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2108.59938 |
141 | Fan:OnOff | CORRIDORFLR2 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
142 | ZoneHVAC:PackagedTerminalAirConditioner | 201 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.14700 |
143 | ZoneHVAC:PackagedTerminalAirConditioner | 201 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
144 | ZoneHVAC:PackagedTerminalAirConditioner | 201 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.14700 |
145 | ZoneHVAC:PackagedTerminalAirConditioner | 201 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
146 | ZoneHVAC:PackagedTerminalAirConditioner | 201 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.14700 |
147 | ZoneHVAC:PackagedTerminalAirConditioner | 201 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
148 | ZoneHVAC:PackagedTerminalAirConditioner | 201 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34741E-002 |
149 | ZoneHVAC:PackagedTerminalAirConditioner | 201 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
150 | ZoneHVAC:PackagedTerminalAirConditioner | 201 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34741E-002 |
151 | ZoneHVAC:PackagedTerminalAirConditioner | 201 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
152 | ZoneHVAC:PackagedTerminalAirConditioner | 201 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34741E-002 |
153 | ZoneHVAC:PackagedTerminalAirConditioner | 201 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
154 | Coil:Cooling:DX:SingleSpeed | 201 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
155 | Coil:Cooling:DX:SingleSpeed | 201 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1734.41807 |
156 | Coil:Cooling:DX:SingleSpeed | 201 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
157 | Coil:Cooling:DX:SingleSpeed | 201 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
158 | Coil:Heating:Electric | 201 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.49778 |
159 | Fan:OnOff | 201 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
160 | ZoneHVAC:PackagedTerminalAirConditioner | 202_205 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.62699 |
161 | ZoneHVAC:PackagedTerminalAirConditioner | 202_205 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.51920 |
162 | ZoneHVAC:PackagedTerminalAirConditioner | 202_205 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.62699 |
163 | ZoneHVAC:PackagedTerminalAirConditioner | 202_205 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.51920 |
164 | ZoneHVAC:PackagedTerminalAirConditioner | 202_205 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.62699 |
165 | ZoneHVAC:PackagedTerminalAirConditioner | 202_205 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.51920 |
166 | ZoneHVAC:PackagedTerminalAirConditioner | 202_205 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.38964E-002 |
167 | ZoneHVAC:PackagedTerminalAirConditioner | 202_205 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.39108E-002 |
168 | ZoneHVAC:PackagedTerminalAirConditioner | 202_205 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.38964E-002 |
169 | ZoneHVAC:PackagedTerminalAirConditioner | 202_205 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.39108E-002 |
170 | ZoneHVAC:PackagedTerminalAirConditioner | 202_205 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.38964E-002 |
171 | ZoneHVAC:PackagedTerminalAirConditioner | 202_205 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.39108E-002 |
172 | Coil:Cooling:DX:SingleSpeed | 202_205 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.51920 |
173 | Coil:Cooling:DX:SingleSpeed | 202_205 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6769.88057 |
174 | Coil:Cooling:DX:SingleSpeed | 202_205 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 10550.99667 |
175 | Coil:Cooling:DX:SingleSpeed | 202_205 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
176 | Coil:Heating:Electric | 202_205 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2973.99113 |
177 | Fan:OnOff | 202_205 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.52000 |
178 | ZoneHVAC:PackagedTerminalAirConditioner | 206_208 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.51317 |
179 | ZoneHVAC:PackagedTerminalAirConditioner | 206_208 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.38940 |
180 | ZoneHVAC:PackagedTerminalAirConditioner | 206_208 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.51317 |
181 | ZoneHVAC:PackagedTerminalAirConditioner | 206_208 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.38940 |
182 | ZoneHVAC:PackagedTerminalAirConditioner | 206_208 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.51317 |
183 | ZoneHVAC:PackagedTerminalAirConditioner | 206_208 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.38940 |
184 | ZoneHVAC:PackagedTerminalAirConditioner | 206_208 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 4.27148E-002 |
185 | ZoneHVAC:PackagedTerminalAirConditioner | 206_208 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 4.27312E-002 |
186 | ZoneHVAC:PackagedTerminalAirConditioner | 206_208 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 4.27148E-002 |
187 | ZoneHVAC:PackagedTerminalAirConditioner | 206_208 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 4.27312E-002 |
188 | ZoneHVAC:PackagedTerminalAirConditioner | 206_208 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 4.27148E-002 |
189 | ZoneHVAC:PackagedTerminalAirConditioner | 206_208 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 4.27312E-002 |
190 | Coil:Cooling:DX:SingleSpeed | 206_208 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.38940 |
191 | Coil:Cooling:DX:SingleSpeed | 206_208 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5054.49176 |
192 | Coil:Cooling:DX:SingleSpeed | 206_208 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 7913.24750 |
193 | Coil:Cooling:DX:SingleSpeed | 206_208 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
194 | Coil:Heating:Electric | 206_208 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2356.99022 |
195 | Fan:OnOff | 206_208 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.39000 |
196 | ZoneHVAC:PackagedTerminalAirConditioner | 209_212 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.59809 |
197 | ZoneHVAC:PackagedTerminalAirConditioner | 209_212 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.51920 |
198 | ZoneHVAC:PackagedTerminalAirConditioner | 209_212 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.59809 |
199 | ZoneHVAC:PackagedTerminalAirConditioner | 209_212 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.51920 |
200 | ZoneHVAC:PackagedTerminalAirConditioner | 209_212 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.59809 |
201 | ZoneHVAC:PackagedTerminalAirConditioner | 209_212 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.51920 |
202 | ZoneHVAC:PackagedTerminalAirConditioner | 209_212 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.38964E-002 |
203 | ZoneHVAC:PackagedTerminalAirConditioner | 209_212 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.39108E-002 |
204 | ZoneHVAC:PackagedTerminalAirConditioner | 209_212 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.38964E-002 |
205 | ZoneHVAC:PackagedTerminalAirConditioner | 209_212 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.39108E-002 |
206 | ZoneHVAC:PackagedTerminalAirConditioner | 209_212 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.38964E-002 |
207 | ZoneHVAC:PackagedTerminalAirConditioner | 209_212 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.39108E-002 |
208 | Coil:Cooling:DX:SingleSpeed | 209_212 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.51920 |
209 | Coil:Cooling:DX:SingleSpeed | 209_212 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6819.82625 |
210 | Coil:Cooling:DX:SingleSpeed | 209_212 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 10550.99667 |
211 | Coil:Cooling:DX:SingleSpeed | 209_212 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
212 | Coil:Heating:Electric | 209_212 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2973.99113 |
213 | Fan:OnOff | 209_212 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.52000 |
214 | ZoneHVAC:PackagedTerminalAirConditioner | 213 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.17422 |
215 | ZoneHVAC:PackagedTerminalAirConditioner | 213 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
216 | ZoneHVAC:PackagedTerminalAirConditioner | 213 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.17422 |
217 | ZoneHVAC:PackagedTerminalAirConditioner | 213 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
218 | ZoneHVAC:PackagedTerminalAirConditioner | 213 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.17422 |
219 | ZoneHVAC:PackagedTerminalAirConditioner | 213 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
220 | ZoneHVAC:PackagedTerminalAirConditioner | 213 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34741E-002 |
221 | ZoneHVAC:PackagedTerminalAirConditioner | 213 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
222 | ZoneHVAC:PackagedTerminalAirConditioner | 213 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34741E-002 |
223 | ZoneHVAC:PackagedTerminalAirConditioner | 213 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
224 | ZoneHVAC:PackagedTerminalAirConditioner | 213 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34741E-002 |
225 | ZoneHVAC:PackagedTerminalAirConditioner | 213 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
226 | Coil:Cooling:DX:SingleSpeed | 213 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
227 | Coil:Cooling:DX:SingleSpeed | 213 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1576.53562 |
228 | Coil:Cooling:DX:SingleSpeed | 213 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
229 | Coil:Cooling:DX:SingleSpeed | 213 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
230 | Coil:Heating:Electric | 213 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.49778 |
231 | Fan:OnOff | 213 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
232 | ZoneHVAC:PackagedTerminalAirConditioner | 214 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.20663 |
233 | ZoneHVAC:PackagedTerminalAirConditioner | 214 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
234 | ZoneHVAC:PackagedTerminalAirConditioner | 214 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.20663 |
235 | ZoneHVAC:PackagedTerminalAirConditioner | 214 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
236 | ZoneHVAC:PackagedTerminalAirConditioner | 214 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.20663 |
237 | ZoneHVAC:PackagedTerminalAirConditioner | 214 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
238 | ZoneHVAC:PackagedTerminalAirConditioner | 214 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34731E-002 |
239 | ZoneHVAC:PackagedTerminalAirConditioner | 214 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
240 | ZoneHVAC:PackagedTerminalAirConditioner | 214 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34731E-002 |
241 | ZoneHVAC:PackagedTerminalAirConditioner | 214 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
242 | ZoneHVAC:PackagedTerminalAirConditioner | 214 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34731E-002 |
243 | ZoneHVAC:PackagedTerminalAirConditioner | 214 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
244 | Coil:Cooling:DX:SingleSpeed | 214 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
245 | Coil:Cooling:DX:SingleSpeed | 214 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1603.86058 |
246 | Coil:Cooling:DX:SingleSpeed | 214 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
247 | Coil:Cooling:DX:SingleSpeed | 214 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
248 | Coil:Heating:Electric | 214 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.44502 |
249 | Fan:OnOff | 214 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
250 | ZoneHVAC:PackagedTerminalAirConditioner | 215_218 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.01231 |
251 | ZoneHVAC:PackagedTerminalAirConditioner | 215_218 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.51920 |
252 | ZoneHVAC:PackagedTerminalAirConditioner | 215_218 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 2.01231 |
253 | ZoneHVAC:PackagedTerminalAirConditioner | 215_218 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.51920 |
254 | ZoneHVAC:PackagedTerminalAirConditioner | 215_218 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 2.01231 |
255 | ZoneHVAC:PackagedTerminalAirConditioner | 215_218 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.51920 |
256 | ZoneHVAC:PackagedTerminalAirConditioner | 215_218 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.38926E-002 |
257 | ZoneHVAC:PackagedTerminalAirConditioner | 215_218 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.39108E-002 |
258 | ZoneHVAC:PackagedTerminalAirConditioner | 215_218 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.38926E-002 |
259 | ZoneHVAC:PackagedTerminalAirConditioner | 215_218 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.39108E-002 |
260 | ZoneHVAC:PackagedTerminalAirConditioner | 215_218 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.38926E-002 |
261 | ZoneHVAC:PackagedTerminalAirConditioner | 215_218 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.39108E-002 |
262 | Coil:Cooling:DX:SingleSpeed | 215_218 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.51920 |
263 | Coil:Cooling:DX:SingleSpeed | 215_218 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6058.43325 |
264 | Coil:Cooling:DX:SingleSpeed | 215_218 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 10550.99667 |
265 | Coil:Cooling:DX:SingleSpeed | 215_218 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
266 | Coil:Heating:Electric | 215_218 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2973.78010 |
267 | Fan:OnOff | 215_218 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.52000 |
268 | ZoneHVAC:PackagedTerminalAirConditioner | 219 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.12091 |
269 | ZoneHVAC:PackagedTerminalAirConditioner | 219 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
270 | ZoneHVAC:PackagedTerminalAirConditioner | 219 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 1.12091 |
271 | ZoneHVAC:PackagedTerminalAirConditioner | 219 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
272 | ZoneHVAC:PackagedTerminalAirConditioner | 219 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 1.12091 |
273 | ZoneHVAC:PackagedTerminalAirConditioner | 219 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
274 | ZoneHVAC:PackagedTerminalAirConditioner | 219 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34731E-002 |
275 | ZoneHVAC:PackagedTerminalAirConditioner | 219 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
276 | ZoneHVAC:PackagedTerminalAirConditioner | 219 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34731E-002 |
277 | ZoneHVAC:PackagedTerminalAirConditioner | 219 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
278 | ZoneHVAC:PackagedTerminalAirConditioner | 219 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34731E-002 |
279 | ZoneHVAC:PackagedTerminalAirConditioner | 219 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
280 | Coil:Cooling:DX:SingleSpeed | 219 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
281 | Coil:Cooling:DX:SingleSpeed | 219 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1465.63180 |
282 | Coil:Cooling:DX:SingleSpeed | 219 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
283 | Coil:Cooling:DX:SingleSpeed | 219 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
284 | Coil:Heating:Electric | 219 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.44502 |
285 | Fan:OnOff | 219 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
286 | ZoneHVAC:PackagedTerminalAirConditioner | 220_223 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.64889 |
287 | ZoneHVAC:PackagedTerminalAirConditioner | 220_223 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.51920 |
288 | ZoneHVAC:PackagedTerminalAirConditioner | 220_223 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.64889 |
289 | ZoneHVAC:PackagedTerminalAirConditioner | 220_223 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.51920 |
290 | ZoneHVAC:PackagedTerminalAirConditioner | 220_223 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.64889 |
291 | ZoneHVAC:PackagedTerminalAirConditioner | 220_223 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.51920 |
292 | ZoneHVAC:PackagedTerminalAirConditioner | 220_223 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.38926E-002 |
293 | ZoneHVAC:PackagedTerminalAirConditioner | 220_223 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.39108E-002 |
294 | ZoneHVAC:PackagedTerminalAirConditioner | 220_223 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.38926E-002 |
295 | ZoneHVAC:PackagedTerminalAirConditioner | 220_223 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.39108E-002 |
296 | ZoneHVAC:PackagedTerminalAirConditioner | 220_223 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.38926E-002 |
297 | ZoneHVAC:PackagedTerminalAirConditioner | 220_223 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.39108E-002 |
298 | Coil:Cooling:DX:SingleSpeed | 220_223 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.51920 |
299 | Coil:Cooling:DX:SingleSpeed | 220_223 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6754.01598 |
300 | Coil:Cooling:DX:SingleSpeed | 220_223 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 10550.99667 |
301 | Coil:Cooling:DX:SingleSpeed | 220_223 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
302 | Coil:Heating:Electric | 220_223 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2973.78010 |
303 | Fan:OnOff | 220_223 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.52000 |
304 | ZoneHVAC:PackagedTerminalAirConditioner | 224 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.19245 |
305 | ZoneHVAC:PackagedTerminalAirConditioner | 224 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
306 | ZoneHVAC:PackagedTerminalAirConditioner | 224 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.19245 |
307 | ZoneHVAC:PackagedTerminalAirConditioner | 224 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
308 | ZoneHVAC:PackagedTerminalAirConditioner | 224 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.19245 |
309 | ZoneHVAC:PackagedTerminalAirConditioner | 224 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
310 | ZoneHVAC:PackagedTerminalAirConditioner | 224 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34731E-002 |
311 | ZoneHVAC:PackagedTerminalAirConditioner | 224 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
312 | ZoneHVAC:PackagedTerminalAirConditioner | 224 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34731E-002 |
313 | ZoneHVAC:PackagedTerminalAirConditioner | 224 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
314 | ZoneHVAC:PackagedTerminalAirConditioner | 224 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34731E-002 |
315 | ZoneHVAC:PackagedTerminalAirConditioner | 224 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
316 | Coil:Cooling:DX:SingleSpeed | 224 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
317 | Coil:Cooling:DX:SingleSpeed | 224 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1644.26992 |
318 | Coil:Cooling:DX:SingleSpeed | 224 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
319 | Coil:Cooling:DX:SingleSpeed | 224 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
320 | Coil:Heating:Electric | 224 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.44502 |
321 | Fan:OnOff | 224 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
322 | ZoneHVAC:UnitHeater | FRONTSTAIRSFLR2 UNITHEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 6.11407E-003 |
323 | Fan:ConstantVolume | FRONTSTAIRSFLR2UNITHEATERFAN | Design Size Maximum Flow Rate [m3/s] | 6.11407E-003 |
324 | Coil:Heating:Electric | FRONTSTAIRSFLR2UNITHEATERHEATINGCOIL | Design Size Nominal Capacity [W] | 291.70840 |
325 | ZoneHVAC:UnitHeater | REARSTAIRSFLR3 UNITHEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 6.11554E-003 |
326 | Fan:ConstantVolume | REARSTAIRSFLR3UNITHEATERFAN | Design Size Maximum Flow Rate [m3/s] | 6.11554E-003 |
327 | Coil:Heating:Electric | REARSTAIRSFLR3UNITHEATERHEATINGCOIL | Design Size Nominal Capacity [W] | 291.77826 |
328 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR3 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.10674 |
329 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR3 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
330 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR3 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.10674 |
331 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR3 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
332 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR3 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.10674 |
333 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR3 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
334 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR3 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 3.82133E-002 |
335 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR3 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 3.82254E-002 |
336 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR3 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 3.82133E-002 |
337 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR3 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 3.82254E-002 |
338 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR3 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 3.82133E-002 |
339 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR3 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 3.82254E-002 |
340 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR3 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
341 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR3 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
342 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR3 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
343 | Coil:Heating:Electric | CORRIDORFLR3 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2108.59938 |
344 | Fan:OnOff | CORRIDORFLR3 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
345 | ZoneHVAC:PackagedTerminalAirConditioner | 301 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.11681 |
346 | ZoneHVAC:PackagedTerminalAirConditioner | 301 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
347 | ZoneHVAC:PackagedTerminalAirConditioner | 301 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.11681 |
348 | ZoneHVAC:PackagedTerminalAirConditioner | 301 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
349 | ZoneHVAC:PackagedTerminalAirConditioner | 301 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.11681 |
350 | ZoneHVAC:PackagedTerminalAirConditioner | 301 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
351 | ZoneHVAC:PackagedTerminalAirConditioner | 301 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34741E-002 |
352 | ZoneHVAC:PackagedTerminalAirConditioner | 301 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
353 | ZoneHVAC:PackagedTerminalAirConditioner | 301 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34741E-002 |
354 | ZoneHVAC:PackagedTerminalAirConditioner | 301 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
355 | ZoneHVAC:PackagedTerminalAirConditioner | 301 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34741E-002 |
356 | ZoneHVAC:PackagedTerminalAirConditioner | 301 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
357 | Coil:Cooling:DX:SingleSpeed | 301 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
358 | Coil:Cooling:DX:SingleSpeed | 301 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1825.80000 |
359 | Coil:Cooling:DX:SingleSpeed | 301 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
360 | Coil:Cooling:DX:SingleSpeed | 301 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
361 | Coil:Heating:Electric | 301 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.49778 |
362 | Fan:OnOff | 301 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
363 | ZoneHVAC:PackagedTerminalAirConditioner | 302_305 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.25102 |
364 | ZoneHVAC:PackagedTerminalAirConditioner | 302_305 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.51920 |
365 | ZoneHVAC:PackagedTerminalAirConditioner | 302_305 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.25102 |
366 | ZoneHVAC:PackagedTerminalAirConditioner | 302_305 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.51920 |
367 | ZoneHVAC:PackagedTerminalAirConditioner | 302_305 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.25102 |
368 | ZoneHVAC:PackagedTerminalAirConditioner | 302_305 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.51920 |
369 | ZoneHVAC:PackagedTerminalAirConditioner | 302_305 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.38964E-002 |
370 | ZoneHVAC:PackagedTerminalAirConditioner | 302_305 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.39108E-002 |
371 | ZoneHVAC:PackagedTerminalAirConditioner | 302_305 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.38964E-002 |
372 | ZoneHVAC:PackagedTerminalAirConditioner | 302_305 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.39108E-002 |
373 | ZoneHVAC:PackagedTerminalAirConditioner | 302_305 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.38964E-002 |
374 | ZoneHVAC:PackagedTerminalAirConditioner | 302_305 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.39108E-002 |
375 | Coil:Cooling:DX:SingleSpeed | 302_305 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.51920 |
376 | Coil:Cooling:DX:SingleSpeed | 302_305 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 8338.16843 |
377 | Coil:Cooling:DX:SingleSpeed | 302_305 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 10550.99667 |
378 | Coil:Cooling:DX:SingleSpeed | 302_305 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
379 | Coil:Heating:Electric | 302_305 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2973.99113 |
380 | Fan:OnOff | 302_305 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.52000 |
381 | ZoneHVAC:PackagedTerminalAirConditioner | 306_308 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.21623 |
382 | ZoneHVAC:PackagedTerminalAirConditioner | 306_308 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.38940 |
383 | ZoneHVAC:PackagedTerminalAirConditioner | 306_308 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.21623 |
384 | ZoneHVAC:PackagedTerminalAirConditioner | 306_308 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.38940 |
385 | ZoneHVAC:PackagedTerminalAirConditioner | 306_308 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.21623 |
386 | ZoneHVAC:PackagedTerminalAirConditioner | 306_308 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.38940 |
387 | ZoneHVAC:PackagedTerminalAirConditioner | 306_308 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 4.27148E-002 |
388 | ZoneHVAC:PackagedTerminalAirConditioner | 306_308 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 4.27312E-002 |
389 | ZoneHVAC:PackagedTerminalAirConditioner | 306_308 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 4.27148E-002 |
390 | ZoneHVAC:PackagedTerminalAirConditioner | 306_308 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 4.27312E-002 |
391 | ZoneHVAC:PackagedTerminalAirConditioner | 306_308 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 4.27148E-002 |
392 | ZoneHVAC:PackagedTerminalAirConditioner | 306_308 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 4.27312E-002 |
393 | Coil:Cooling:DX:SingleSpeed | 306_308 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.38940 |
394 | Coil:Cooling:DX:SingleSpeed | 306_308 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6103.48781 |
395 | Coil:Cooling:DX:SingleSpeed | 306_308 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 7913.24750 |
396 | Coil:Cooling:DX:SingleSpeed | 306_308 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
397 | Coil:Heating:Electric | 306_308 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2356.99022 |
398 | Fan:OnOff | 306_308 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.39000 |
399 | ZoneHVAC:PackagedTerminalAirConditioner | 309_312 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.51920 |
400 | ZoneHVAC:PackagedTerminalAirConditioner | 309_312 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.51920 |
401 | ZoneHVAC:PackagedTerminalAirConditioner | 309_312 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.51920 |
402 | ZoneHVAC:PackagedTerminalAirConditioner | 309_312 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.38964E-002 |
403 | ZoneHVAC:PackagedTerminalAirConditioner | 309_312 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.39108E-002 |
404 | ZoneHVAC:PackagedTerminalAirConditioner | 309_312 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.38964E-002 |
405 | ZoneHVAC:PackagedTerminalAirConditioner | 309_312 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.39108E-002 |
406 | ZoneHVAC:PackagedTerminalAirConditioner | 309_312 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.38964E-002 |
407 | ZoneHVAC:PackagedTerminalAirConditioner | 309_312 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.39108E-002 |
408 | Coil:Cooling:DX:SingleSpeed | 309_312 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.51920 |
409 | Coil:Cooling:DX:SingleSpeed | 309_312 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6858.92935 |
410 | Coil:Cooling:DX:SingleSpeed | 309_312 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 10550.99667 |
411 | Coil:Cooling:DX:SingleSpeed | 309_312 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
412 | Coil:Heating:Electric | 309_312 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2973.99113 |
413 | Fan:OnOff | 309_312 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.52000 |
414 | ZoneHVAC:PackagedTerminalAirConditioner | 313 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.10112 |
415 | ZoneHVAC:PackagedTerminalAirConditioner | 313 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
416 | ZoneHVAC:PackagedTerminalAirConditioner | 313 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.10112 |
417 | ZoneHVAC:PackagedTerminalAirConditioner | 313 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
418 | ZoneHVAC:PackagedTerminalAirConditioner | 313 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.10112 |
419 | ZoneHVAC:PackagedTerminalAirConditioner | 313 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
420 | ZoneHVAC:PackagedTerminalAirConditioner | 313 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34741E-002 |
421 | ZoneHVAC:PackagedTerminalAirConditioner | 313 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
422 | ZoneHVAC:PackagedTerminalAirConditioner | 313 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34741E-002 |
423 | ZoneHVAC:PackagedTerminalAirConditioner | 313 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
424 | ZoneHVAC:PackagedTerminalAirConditioner | 313 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34741E-002 |
425 | ZoneHVAC:PackagedTerminalAirConditioner | 313 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
426 | Coil:Cooling:DX:SingleSpeed | 313 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
427 | Coil:Cooling:DX:SingleSpeed | 313 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1717.15705 |
428 | Coil:Cooling:DX:SingleSpeed | 313 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
429 | Coil:Cooling:DX:SingleSpeed | 313 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
430 | Coil:Heating:Electric | 313 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.49778 |
431 | Fan:OnOff | 313 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
432 | ZoneHVAC:PackagedTerminalAirConditioner | 314 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.18105 |
433 | ZoneHVAC:PackagedTerminalAirConditioner | 314 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
434 | ZoneHVAC:PackagedTerminalAirConditioner | 314 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.18105 |
435 | ZoneHVAC:PackagedTerminalAirConditioner | 314 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
436 | ZoneHVAC:PackagedTerminalAirConditioner | 314 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.18105 |
437 | ZoneHVAC:PackagedTerminalAirConditioner | 314 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
438 | ZoneHVAC:PackagedTerminalAirConditioner | 314 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34731E-002 |
439 | ZoneHVAC:PackagedTerminalAirConditioner | 314 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
440 | ZoneHVAC:PackagedTerminalAirConditioner | 314 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34731E-002 |
441 | ZoneHVAC:PackagedTerminalAirConditioner | 314 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
442 | ZoneHVAC:PackagedTerminalAirConditioner | 314 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34731E-002 |
443 | ZoneHVAC:PackagedTerminalAirConditioner | 314 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
444 | Coil:Cooling:DX:SingleSpeed | 314 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
445 | Coil:Cooling:DX:SingleSpeed | 314 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1624.80982 |
446 | Coil:Cooling:DX:SingleSpeed | 314 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
447 | Coil:Cooling:DX:SingleSpeed | 314 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
448 | Coil:Heating:Electric | 314 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.44502 |
449 | Fan:OnOff | 314 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
450 | ZoneHVAC:PackagedTerminalAirConditioner | 315_318 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.74527 |
451 | ZoneHVAC:PackagedTerminalAirConditioner | 315_318 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.51920 |
452 | ZoneHVAC:PackagedTerminalAirConditioner | 315_318 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.74527 |
453 | ZoneHVAC:PackagedTerminalAirConditioner | 315_318 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.51920 |
454 | ZoneHVAC:PackagedTerminalAirConditioner | 315_318 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.74527 |
455 | ZoneHVAC:PackagedTerminalAirConditioner | 315_318 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.51920 |
456 | ZoneHVAC:PackagedTerminalAirConditioner | 315_318 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.38926E-002 |
457 | ZoneHVAC:PackagedTerminalAirConditioner | 315_318 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.39108E-002 |
458 | ZoneHVAC:PackagedTerminalAirConditioner | 315_318 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.38926E-002 |
459 | ZoneHVAC:PackagedTerminalAirConditioner | 315_318 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.39108E-002 |
460 | ZoneHVAC:PackagedTerminalAirConditioner | 315_318 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.38926E-002 |
461 | ZoneHVAC:PackagedTerminalAirConditioner | 315_318 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.39108E-002 |
462 | Coil:Cooling:DX:SingleSpeed | 315_318 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.51920 |
463 | Coil:Cooling:DX:SingleSpeed | 315_318 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6606.25924 |
464 | Coil:Cooling:DX:SingleSpeed | 315_318 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 10550.99667 |
465 | Coil:Cooling:DX:SingleSpeed | 315_318 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
466 | Coil:Heating:Electric | 315_318 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2973.78010 |
467 | Fan:OnOff | 315_318 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.52000 |
468 | ZoneHVAC:PackagedTerminalAirConditioner | 319 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.18571 |
469 | ZoneHVAC:PackagedTerminalAirConditioner | 319 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
470 | ZoneHVAC:PackagedTerminalAirConditioner | 319 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.18571 |
471 | ZoneHVAC:PackagedTerminalAirConditioner | 319 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
472 | ZoneHVAC:PackagedTerminalAirConditioner | 319 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.18571 |
473 | ZoneHVAC:PackagedTerminalAirConditioner | 319 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
474 | ZoneHVAC:PackagedTerminalAirConditioner | 319 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34731E-002 |
475 | ZoneHVAC:PackagedTerminalAirConditioner | 319 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
476 | ZoneHVAC:PackagedTerminalAirConditioner | 319 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34731E-002 |
477 | ZoneHVAC:PackagedTerminalAirConditioner | 319 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
478 | ZoneHVAC:PackagedTerminalAirConditioner | 319 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34731E-002 |
479 | ZoneHVAC:PackagedTerminalAirConditioner | 319 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
480 | Coil:Cooling:DX:SingleSpeed | 319 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
481 | Coil:Cooling:DX:SingleSpeed | 319 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1655.80248 |
482 | Coil:Cooling:DX:SingleSpeed | 319 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
483 | Coil:Cooling:DX:SingleSpeed | 319 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
484 | Coil:Heating:Electric | 319 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.44502 |
485 | Fan:OnOff | 319 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
486 | ZoneHVAC:PackagedTerminalAirConditioner | 320_323 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.58566 |
487 | ZoneHVAC:PackagedTerminalAirConditioner | 320_323 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.51920 |
488 | ZoneHVAC:PackagedTerminalAirConditioner | 320_323 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.58566 |
489 | ZoneHVAC:PackagedTerminalAirConditioner | 320_323 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.51920 |
490 | ZoneHVAC:PackagedTerminalAirConditioner | 320_323 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.58566 |
491 | ZoneHVAC:PackagedTerminalAirConditioner | 320_323 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.51920 |
492 | ZoneHVAC:PackagedTerminalAirConditioner | 320_323 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.38926E-002 |
493 | ZoneHVAC:PackagedTerminalAirConditioner | 320_323 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.39108E-002 |
494 | ZoneHVAC:PackagedTerminalAirConditioner | 320_323 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.38926E-002 |
495 | ZoneHVAC:PackagedTerminalAirConditioner | 320_323 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.39108E-002 |
496 | ZoneHVAC:PackagedTerminalAirConditioner | 320_323 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.38926E-002 |
497 | ZoneHVAC:PackagedTerminalAirConditioner | 320_323 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.39108E-002 |
498 | Coil:Cooling:DX:SingleSpeed | 320_323 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.51920 |
499 | Coil:Cooling:DX:SingleSpeed | 320_323 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6844.32490 |
500 | Coil:Cooling:DX:SingleSpeed | 320_323 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 10550.99667 |
501 | Coil:Cooling:DX:SingleSpeed | 320_323 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
502 | Coil:Heating:Electric | 320_323 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2973.78010 |
503 | Fan:OnOff | 320_323 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.52000 |
504 | ZoneHVAC:PackagedTerminalAirConditioner | 324 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.10665 |
505 | ZoneHVAC:PackagedTerminalAirConditioner | 324 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
506 | ZoneHVAC:PackagedTerminalAirConditioner | 324 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.10665 |
507 | ZoneHVAC:PackagedTerminalAirConditioner | 324 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
508 | ZoneHVAC:PackagedTerminalAirConditioner | 324 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.10665 |
509 | ZoneHVAC:PackagedTerminalAirConditioner | 324 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
510 | ZoneHVAC:PackagedTerminalAirConditioner | 324 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34731E-002 |
511 | ZoneHVAC:PackagedTerminalAirConditioner | 324 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
512 | ZoneHVAC:PackagedTerminalAirConditioner | 324 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34731E-002 |
513 | ZoneHVAC:PackagedTerminalAirConditioner | 324 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
514 | ZoneHVAC:PackagedTerminalAirConditioner | 324 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34731E-002 |
515 | ZoneHVAC:PackagedTerminalAirConditioner | 324 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
516 | Coil:Cooling:DX:SingleSpeed | 324 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
517 | Coil:Cooling:DX:SingleSpeed | 324 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1821.54818 |
518 | Coil:Cooling:DX:SingleSpeed | 324 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
519 | Coil:Cooling:DX:SingleSpeed | 324 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
520 | Coil:Heating:Electric | 324 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.44502 |
521 | Fan:OnOff | 324 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
522 | ZoneHVAC:UnitHeater | FRONTSTAIRSFLR3 UNITHEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 6.11407E-003 |
523 | Fan:ConstantVolume | FRONTSTAIRSFLR3UNITHEATERFAN | Design Size Maximum Flow Rate [m3/s] | 6.11407E-003 |
524 | Coil:Heating:Electric | FRONTSTAIRSFLR3UNITHEATERHEATINGCOIL | Design Size Nominal Capacity [W] | 291.70840 |
525 | ZoneHVAC:UnitHeater | REARSTAIRSFLR4 UNITHEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 6.11554E-003 |
526 | Fan:ConstantVolume | REARSTAIRSFLR4UNITHEATERFAN | Design Size Maximum Flow Rate [m3/s] | 6.11554E-003 |
527 | Coil:Heating:Electric | REARSTAIRSFLR4UNITHEATERHEATINGCOIL | Design Size Nominal Capacity [W] | 291.77826 |
528 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR4 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.15943 |
529 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR4 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
530 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR4 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.15943 |
531 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR4 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
532 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR4 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.15943 |
533 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR4 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
534 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR4 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 3.82133E-002 |
535 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR4 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 3.82254E-002 |
536 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR4 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 3.82133E-002 |
537 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR4 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 3.82254E-002 |
538 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR4 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 3.82133E-002 |
539 | ZoneHVAC:PackagedTerminalAirConditioner | CORRIDORFLR4 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 3.82254E-002 |
540 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR4 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
541 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR4 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
542 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR4 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
543 | Coil:Heating:Electric | CORRIDORFLR4 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2264.61796 |
544 | Fan:OnOff | CORRIDORFLR4 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
545 | ZoneHVAC:PackagedTerminalAirConditioner | 401 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.22471 |
546 | ZoneHVAC:PackagedTerminalAirConditioner | 401 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
547 | ZoneHVAC:PackagedTerminalAirConditioner | 401 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.22471 |
548 | ZoneHVAC:PackagedTerminalAirConditioner | 401 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
549 | ZoneHVAC:PackagedTerminalAirConditioner | 401 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.22471 |
550 | ZoneHVAC:PackagedTerminalAirConditioner | 401 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
551 | ZoneHVAC:PackagedTerminalAirConditioner | 401 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34741E-002 |
552 | ZoneHVAC:PackagedTerminalAirConditioner | 401 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
553 | ZoneHVAC:PackagedTerminalAirConditioner | 401 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34741E-002 |
554 | ZoneHVAC:PackagedTerminalAirConditioner | 401 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
555 | ZoneHVAC:PackagedTerminalAirConditioner | 401 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34741E-002 |
556 | ZoneHVAC:PackagedTerminalAirConditioner | 401 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
557 | Coil:Cooling:DX:SingleSpeed | 401 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
558 | Coil:Cooling:DX:SingleSpeed | 401 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1633.36290 |
559 | Coil:Cooling:DX:SingleSpeed | 401 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
560 | Coil:Cooling:DX:SingleSpeed | 401 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
561 | Coil:Heating:Electric | 401 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 825.22764 |
562 | Fan:OnOff | 401 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
563 | ZoneHVAC:PackagedTerminalAirConditioner | 402_405 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.33575 |
564 | ZoneHVAC:PackagedTerminalAirConditioner | 402_405 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.51920 |
565 | ZoneHVAC:PackagedTerminalAirConditioner | 402_405 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.33575 |
566 | ZoneHVAC:PackagedTerminalAirConditioner | 402_405 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.51920 |
567 | ZoneHVAC:PackagedTerminalAirConditioner | 402_405 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.33575 |
568 | ZoneHVAC:PackagedTerminalAirConditioner | 402_405 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.51920 |
569 | ZoneHVAC:PackagedTerminalAirConditioner | 402_405 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.38964E-002 |
570 | ZoneHVAC:PackagedTerminalAirConditioner | 402_405 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.39108E-002 |
571 | ZoneHVAC:PackagedTerminalAirConditioner | 402_405 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.38964E-002 |
572 | ZoneHVAC:PackagedTerminalAirConditioner | 402_405 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.39108E-002 |
573 | ZoneHVAC:PackagedTerminalAirConditioner | 402_405 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.38964E-002 |
574 | ZoneHVAC:PackagedTerminalAirConditioner | 402_405 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.39108E-002 |
575 | Coil:Cooling:DX:SingleSpeed | 402_405 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.51920 |
576 | Coil:Cooling:DX:SingleSpeed | 402_405 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7834.64692 |
577 | Coil:Cooling:DX:SingleSpeed | 402_405 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 10550.99667 |
578 | Coil:Cooling:DX:SingleSpeed | 402_405 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
579 | Coil:Heating:Electric | 402_405 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2973.99113 |
580 | Fan:OnOff | 402_405 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.52000 |
581 | ZoneHVAC:PackagedTerminalAirConditioner | 406_408 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.28523 |
582 | ZoneHVAC:PackagedTerminalAirConditioner | 406_408 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.38940 |
583 | ZoneHVAC:PackagedTerminalAirConditioner | 406_408 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.28523 |
584 | ZoneHVAC:PackagedTerminalAirConditioner | 406_408 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.38940 |
585 | ZoneHVAC:PackagedTerminalAirConditioner | 406_408 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.28523 |
586 | ZoneHVAC:PackagedTerminalAirConditioner | 406_408 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.38940 |
587 | ZoneHVAC:PackagedTerminalAirConditioner | 406_408 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 4.27148E-002 |
588 | ZoneHVAC:PackagedTerminalAirConditioner | 406_408 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 4.27312E-002 |
589 | ZoneHVAC:PackagedTerminalAirConditioner | 406_408 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 4.27148E-002 |
590 | ZoneHVAC:PackagedTerminalAirConditioner | 406_408 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 4.27312E-002 |
591 | ZoneHVAC:PackagedTerminalAirConditioner | 406_408 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 4.27148E-002 |
592 | ZoneHVAC:PackagedTerminalAirConditioner | 406_408 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 4.27312E-002 |
593 | Coil:Cooling:DX:SingleSpeed | 406_408 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.38940 |
594 | Coil:Cooling:DX:SingleSpeed | 406_408 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5775.65783 |
595 | Coil:Cooling:DX:SingleSpeed | 406_408 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 7913.24750 |
596 | Coil:Cooling:DX:SingleSpeed | 406_408 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
597 | Coil:Heating:Electric | 406_408 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2356.99022 |
598 | Fan:OnOff | 406_408 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.39000 |
599 | ZoneHVAC:PackagedTerminalAirConditioner | 409_412 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.67932 |
600 | ZoneHVAC:PackagedTerminalAirConditioner | 409_412 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.51920 |
601 | ZoneHVAC:PackagedTerminalAirConditioner | 409_412 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.67932 |
602 | ZoneHVAC:PackagedTerminalAirConditioner | 409_412 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.51920 |
603 | ZoneHVAC:PackagedTerminalAirConditioner | 409_412 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.67932 |
604 | ZoneHVAC:PackagedTerminalAirConditioner | 409_412 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.51920 |
605 | ZoneHVAC:PackagedTerminalAirConditioner | 409_412 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.38964E-002 |
606 | ZoneHVAC:PackagedTerminalAirConditioner | 409_412 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.39108E-002 |
607 | ZoneHVAC:PackagedTerminalAirConditioner | 409_412 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.38964E-002 |
608 | ZoneHVAC:PackagedTerminalAirConditioner | 409_412 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.39108E-002 |
609 | ZoneHVAC:PackagedTerminalAirConditioner | 409_412 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.38964E-002 |
610 | ZoneHVAC:PackagedTerminalAirConditioner | 409_412 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.39108E-002 |
611 | Coil:Cooling:DX:SingleSpeed | 409_412 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.51920 |
612 | Coil:Cooling:DX:SingleSpeed | 409_412 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6768.07684 |
613 | Coil:Cooling:DX:SingleSpeed | 409_412 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 10550.99667 |
614 | Coil:Cooling:DX:SingleSpeed | 409_412 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
615 | Coil:Heating:Electric | 409_412 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2973.99113 |
616 | Fan:OnOff | 409_412 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.52000 |
617 | ZoneHVAC:PackagedTerminalAirConditioner | 413 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
618 | ZoneHVAC:PackagedTerminalAirConditioner | 413 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
619 | ZoneHVAC:PackagedTerminalAirConditioner | 413 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
620 | ZoneHVAC:PackagedTerminalAirConditioner | 413 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34741E-002 |
621 | ZoneHVAC:PackagedTerminalAirConditioner | 413 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
622 | ZoneHVAC:PackagedTerminalAirConditioner | 413 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34741E-002 |
623 | ZoneHVAC:PackagedTerminalAirConditioner | 413 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
624 | ZoneHVAC:PackagedTerminalAirConditioner | 413 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34741E-002 |
625 | ZoneHVAC:PackagedTerminalAirConditioner | 413 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
626 | Coil:Cooling:DX:SingleSpeed | 413 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
627 | Coil:Cooling:DX:SingleSpeed | 413 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1751.16748 |
628 | Coil:Cooling:DX:SingleSpeed | 413 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
629 | Coil:Cooling:DX:SingleSpeed | 413 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
630 | Coil:Heating:Electric | 413 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 892.86250 |
631 | Fan:OnOff | 413 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
632 | ZoneHVAC:PackagedTerminalAirConditioner | 414 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.14350 |
633 | ZoneHVAC:PackagedTerminalAirConditioner | 414 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
634 | ZoneHVAC:PackagedTerminalAirConditioner | 414 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.14350 |
635 | ZoneHVAC:PackagedTerminalAirConditioner | 414 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
636 | ZoneHVAC:PackagedTerminalAirConditioner | 414 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.14350 |
637 | ZoneHVAC:PackagedTerminalAirConditioner | 414 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
638 | ZoneHVAC:PackagedTerminalAirConditioner | 414 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34731E-002 |
639 | ZoneHVAC:PackagedTerminalAirConditioner | 414 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
640 | ZoneHVAC:PackagedTerminalAirConditioner | 414 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34731E-002 |
641 | ZoneHVAC:PackagedTerminalAirConditioner | 414 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
642 | ZoneHVAC:PackagedTerminalAirConditioner | 414 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34731E-002 |
643 | ZoneHVAC:PackagedTerminalAirConditioner | 414 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
644 | Coil:Cooling:DX:SingleSpeed | 414 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
645 | Coil:Cooling:DX:SingleSpeed | 414 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1732.55191 |
646 | Coil:Cooling:DX:SingleSpeed | 414 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
647 | Coil:Cooling:DX:SingleSpeed | 414 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
648 | Coil:Heating:Electric | 414 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 858.46978 |
649 | Fan:OnOff | 414 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
650 | ZoneHVAC:PackagedTerminalAirConditioner | 415_418 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.73260 |
651 | ZoneHVAC:PackagedTerminalAirConditioner | 415_418 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.51920 |
652 | ZoneHVAC:PackagedTerminalAirConditioner | 415_418 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.73260 |
653 | ZoneHVAC:PackagedTerminalAirConditioner | 415_418 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.51920 |
654 | ZoneHVAC:PackagedTerminalAirConditioner | 415_418 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.73260 |
655 | ZoneHVAC:PackagedTerminalAirConditioner | 415_418 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.51920 |
656 | ZoneHVAC:PackagedTerminalAirConditioner | 415_418 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.38926E-002 |
657 | ZoneHVAC:PackagedTerminalAirConditioner | 415_418 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.39108E-002 |
658 | ZoneHVAC:PackagedTerminalAirConditioner | 415_418 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.38926E-002 |
659 | ZoneHVAC:PackagedTerminalAirConditioner | 415_418 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.39108E-002 |
660 | ZoneHVAC:PackagedTerminalAirConditioner | 415_418 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.38926E-002 |
661 | ZoneHVAC:PackagedTerminalAirConditioner | 415_418 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.39108E-002 |
662 | Coil:Cooling:DX:SingleSpeed | 415_418 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.51920 |
663 | Coil:Cooling:DX:SingleSpeed | 415_418 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6695.75773 |
664 | Coil:Cooling:DX:SingleSpeed | 415_418 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 10550.99667 |
665 | Coil:Cooling:DX:SingleSpeed | 415_418 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
666 | Coil:Heating:Electric | 415_418 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2973.78010 |
667 | Fan:OnOff | 415_418 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.52000 |
668 | ZoneHVAC:PackagedTerminalAirConditioner | 419 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.20688 |
669 | ZoneHVAC:PackagedTerminalAirConditioner | 419 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
670 | ZoneHVAC:PackagedTerminalAirConditioner | 419 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.20688 |
671 | ZoneHVAC:PackagedTerminalAirConditioner | 419 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
672 | ZoneHVAC:PackagedTerminalAirConditioner | 419 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.20688 |
673 | ZoneHVAC:PackagedTerminalAirConditioner | 419 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
674 | ZoneHVAC:PackagedTerminalAirConditioner | 419 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34731E-002 |
675 | ZoneHVAC:PackagedTerminalAirConditioner | 419 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
676 | ZoneHVAC:PackagedTerminalAirConditioner | 419 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34731E-002 |
677 | ZoneHVAC:PackagedTerminalAirConditioner | 419 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
678 | ZoneHVAC:PackagedTerminalAirConditioner | 419 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34731E-002 |
679 | ZoneHVAC:PackagedTerminalAirConditioner | 419 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
680 | Coil:Cooling:DX:SingleSpeed | 419 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
681 | Coil:Cooling:DX:SingleSpeed | 419 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1647.43436 |
682 | Coil:Cooling:DX:SingleSpeed | 419 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
683 | Coil:Cooling:DX:SingleSpeed | 419 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
684 | Coil:Heating:Electric | 419 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 743.44502 |
685 | Fan:OnOff | 419 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
686 | ZoneHVAC:PackagedTerminalAirConditioner | 420_423 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.71365 |
687 | ZoneHVAC:PackagedTerminalAirConditioner | 420_423 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.51920 |
688 | ZoneHVAC:PackagedTerminalAirConditioner | 420_423 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.71365 |
689 | ZoneHVAC:PackagedTerminalAirConditioner | 420_423 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.51920 |
690 | ZoneHVAC:PackagedTerminalAirConditioner | 420_423 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.71365 |
691 | ZoneHVAC:PackagedTerminalAirConditioner | 420_423 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.51920 |
692 | ZoneHVAC:PackagedTerminalAirConditioner | 420_423 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.38926E-002 |
693 | ZoneHVAC:PackagedTerminalAirConditioner | 420_423 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 5.39108E-002 |
694 | ZoneHVAC:PackagedTerminalAirConditioner | 420_423 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.38926E-002 |
695 | ZoneHVAC:PackagedTerminalAirConditioner | 420_423 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 5.39108E-002 |
696 | ZoneHVAC:PackagedTerminalAirConditioner | 420_423 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.38926E-002 |
697 | ZoneHVAC:PackagedTerminalAirConditioner | 420_423 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.39108E-002 |
698 | Coil:Cooling:DX:SingleSpeed | 420_423 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.51920 |
699 | Coil:Cooling:DX:SingleSpeed | 420_423 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6720.25160 |
700 | Coil:Cooling:DX:SingleSpeed | 420_423 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 10550.99667 |
701 | Coil:Cooling:DX:SingleSpeed | 420_423 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
702 | Coil:Heating:Electric | 420_423 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 2973.78010 |
703 | Fan:OnOff | 420_423 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.52000 |
704 | ZoneHVAC:PackagedTerminalAirConditioner | 424 PTAC | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.21092 |
705 | ZoneHVAC:PackagedTerminalAirConditioner | 424 PTAC | User-Specified Cooling Supply Air Flow Rate [m3/s] | 0.12980 |
706 | ZoneHVAC:PackagedTerminalAirConditioner | 424 PTAC | Design Size Heating Supply Air Flow Rate [m3/s] | 0.21092 |
707 | ZoneHVAC:PackagedTerminalAirConditioner | 424 PTAC | User-Specified Heating Supply Air Flow Rate [m3/s] | 0.12980 |
708 | ZoneHVAC:PackagedTerminalAirConditioner | 424 PTAC | Design Size No Load Supply Air Flow Rate [m3/s] | 0.21092 |
709 | ZoneHVAC:PackagedTerminalAirConditioner | 424 PTAC | User-Specified No Load Supply Air Flow Rate [m3/s] | 0.12980 |
710 | ZoneHVAC:PackagedTerminalAirConditioner | 424 PTAC | Design Size Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34731E-002 |
711 | ZoneHVAC:PackagedTerminalAirConditioner | 424 PTAC | User-Specified Outdoor Air Flow Rate During Cooling Operation [m3/s] | 1.34777E-002 |
712 | ZoneHVAC:PackagedTerminalAirConditioner | 424 PTAC | Design Size Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34731E-002 |
713 | ZoneHVAC:PackagedTerminalAirConditioner | 424 PTAC | User-Specified Outdoor Air Flow Rate During Heating Operation [m3/s] | 1.34777E-002 |
714 | ZoneHVAC:PackagedTerminalAirConditioner | 424 PTAC | Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34731E-002 |
715 | ZoneHVAC:PackagedTerminalAirConditioner | 424 PTAC | User-Specified Outdoor Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 1.34777E-002 |
716 | Coil:Cooling:DX:SingleSpeed | 424 PTAC COOLING COIL | User-Specified Rated Air Flow Rate [m3/s] | 0.12980 |
717 | Coil:Cooling:DX:SingleSpeed | 424 PTAC COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 1639.13283 |
718 | Coil:Cooling:DX:SingleSpeed | 424 PTAC COOLING COIL | User-Specified Gross Rated Total Cooling Capacity [W] | 2637.74917 |
719 | Coil:Cooling:DX:SingleSpeed | 424 PTAC COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.76648 |
720 | Coil:Heating:Electric | 424 PTAC HEATING COIL | Design Size Nominal Capacity [W] | 825.83500 |
721 | Fan:OnOff | 424 PTAC SUPPLY FAN | User-Specified Maximum Flow Rate [m3/s] | 0.13000 |
722 | ZoneHVAC:UnitHeater | FRONTSTAIRSFLR4 UNITHEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 6.11407E-003 |
723 | Fan:ConstantVolume | FRONTSTAIRSFLR4UNITHEATERFAN | Design Size Maximum Flow Rate [m3/s] | 6.11407E-003 |
724 | Coil:Heating:Electric | FRONTSTAIRSFLR4UNITHEATERHEATINGCOIL | Design Size Nominal Capacity [W] | 291.70840 |
725 | AirLoopHVAC | SAC_FRONTOFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.43189 |
726 | AirLoopHVAC | SAC_FRONTOFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.43189 |
727 | AirLoopHVAC | SAC_FRONTOFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.43189 |
728 | AirLoopHVAC | SAC_FRONTOFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.43189 |
729 | AirLoopHVAC | SAC_FRONTOFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.43189 |
730 | AirLoopHVAC | SAC_FRONTOFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.43189 |
731 | AirLoopHVAC | SAC_FRONTOFFICE | User Heating Air Flow Ratio [] | 1.00000 |
732 | AirLoopHVAC | SAC_FRONTOFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
733 | AirLoopHVAC | SAC_FRONTLOUNGE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.97800 |
734 | AirLoopHVAC | SAC_FRONTLOUNGE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.97800 |
735 | AirLoopHVAC | SAC_FRONTLOUNGE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.97800 |
736 | AirLoopHVAC | SAC_FRONTLOUNGE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.97800 |
737 | AirLoopHVAC | SAC_FRONTLOUNGE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.97800 |
738 | AirLoopHVAC | SAC_FRONTLOUNGE | Adjusted Main Design Air Flow Rate [m3/s] | 0.97800 |
739 | AirLoopHVAC | SAC_FRONTLOUNGE | User Heating Air Flow Ratio [] | 1.00000 |
740 | AirLoopHVAC | SAC_FRONTLOUNGE | Calculated Heating Air Flow Ratio [] | 1.00000 |
741 | AirLoopHVAC | SAC_MEETINGROOM | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.46693 |
742 | AirLoopHVAC | SAC_MEETINGROOM | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.46693 |
743 | AirLoopHVAC | SAC_MEETINGROOM | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.46693 |
744 | AirLoopHVAC | SAC_MEETINGROOM | Adjusted Heating Design Air Flow Rate [m3/s] | 0.46693 |
745 | AirLoopHVAC | SAC_MEETINGROOM | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.46693 |
746 | AirLoopHVAC | SAC_MEETINGROOM | Adjusted Main Design Air Flow Rate [m3/s] | 0.46693 |
747 | AirLoopHVAC | SAC_MEETINGROOM | User Heating Air Flow Ratio [] | 1.00000 |
748 | AirLoopHVAC | SAC_MEETINGROOM | Calculated Heating Air Flow Ratio [] | 1.00000 |
749 | AirLoopHVAC | SAC_EXC_EMPLGE_RESTRM | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.13722 |
750 | AirLoopHVAC | SAC_EXC_EMPLGE_RESTRM | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.13722 |
751 | AirLoopHVAC | SAC_EXC_EMPLGE_RESTRM | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.13722 |
752 | AirLoopHVAC | SAC_EXC_EMPLGE_RESTRM | Adjusted Heating Design Air Flow Rate [m3/s] | 1.13722 |
753 | AirLoopHVAC | SAC_EXC_EMPLGE_RESTRM | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.13722 |
754 | AirLoopHVAC | SAC_EXC_EMPLGE_RESTRM | Adjusted Main Design Air Flow Rate [m3/s] | 1.13722 |
755 | AirLoopHVAC | SAC_EXC_EMPLGE_RESTRM | User Heating Air Flow Ratio [] | 1.00000 |
756 | AirLoopHVAC | SAC_EXC_EMPLGE_RESTRM | Calculated Heating Air Flow Ratio [] | 1.00000 |
757 | AirLoopHVAC | SAC_FRONTOFFICE | Design Supply Air Flow Rate [m3/s] | 0.43189 |
758 | AirLoopHVAC | SAC_FRONTLOUNGE | Design Supply Air Flow Rate [m3/s] | 0.97800 |
759 | AirLoopHVAC | SAC_MEETINGROOM | Design Supply Air Flow Rate [m3/s] | 0.46693 |
760 | AirLoopHVAC | SAC_EXC_EMPLGE_RESTRM | Design Supply Air Flow Rate [m3/s] | 1.13722 |
761 | Controller:OutdoorAir | SAC_FRONTOFFICE OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.43189 |
762 | Controller:OutdoorAir | SAC_FRONTOFFICE OA CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.63004E-002 |
763 | AirLoopHVAC:UnitarySystem | SAC_FRONTOFFICE | Design Size Supply Air Flow Rate [m3/s] | 0.43189 |
764 | AirLoopHVAC:UnitarySystem | SAC_FRONTOFFICE | Design Size Heating Supply Air Flow Rate [m3/s] | 0.43189 |
765 | AirLoopHVAC:UnitarySystem | SAC_FRONTOFFICE | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.43189 |
766 | AirLoopHVAC:UnitarySystem | SAC_FRONTOFFICE | Design Size No Load Supply Air Flow Rate [m3/s] | 0.43189 |
767 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTOFFICE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.43189 |
768 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTOFFICE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.21595 |
769 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTOFFICE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.28793 |
770 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTOFFICE COOLING COIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 8203.97908 |
771 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTOFFICE COOLING COIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 8554.06000 |
772 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTOFFICE COOLING COIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 4277.03000 |
773 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTOFFICE COOLING COIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 4277.03000 |
774 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTOFFICE COOLING COIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.73828 |
775 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTOFFICE COOLING COIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.73828 |
776 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTOFFICE COOLING COIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.73828 |
777 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTOFFICE COOLING COIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.73828 |
778 | AirLoopHVAC:UnitarySystem | SAC_FRONTOFFICE | User-Specified Nominal Cooling Capacity [W] | 8554.06000 |
779 | AirLoopHVAC:UnitarySystem | SAC_FRONTOFFICE | Design Size Nominal Heating Capacity [W] | 10236.39378 |
780 | AirLoopHVAC:UnitarySystem | SAC_FRONTOFFICE | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
781 | AirLoopHVAC:UnitarySystem | SAC_FRONTOFFICE | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
782 | Fan:SystemModel | SAC_FO_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.43189 |
783 | Fan:SystemModel | SAC_FO_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 483.76899 |
784 | Coil:Heating:Fuel | SAC_FRONTOFFICE HEATING COIL | Design Size Nominal Capacity [W] | 10236.39378 |
785 | Controller:OutdoorAir | SAC_FRONTLOUNGE OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.97800 |
786 | Controller:OutdoorAir | SAC_FRONTLOUNGE OA CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.23598 |
787 | AirLoopHVAC:UnitarySystem | SAC_FRONTLOUNGE | Design Size Supply Air Flow Rate [m3/s] | 0.97800 |
788 | AirLoopHVAC:UnitarySystem | SAC_FRONTLOUNGE | Design Size Heating Supply Air Flow Rate [m3/s] | 0.97800 |
789 | AirLoopHVAC:UnitarySystem | SAC_FRONTLOUNGE | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.97800 |
790 | AirLoopHVAC:UnitarySystem | SAC_FRONTLOUNGE | Design Size No Load Supply Air Flow Rate [m3/s] | 0.64548 |
791 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTLOUNGE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.97800 |
792 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTLOUNGE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.48900 |
793 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTLOUNGE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.65200 |
794 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTLOUNGE COOLING COIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 20959.77735 |
795 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTLOUNGE COOLING COIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 21703.16000 |
796 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTLOUNGE COOLING COIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 10851.58000 |
797 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTLOUNGE COOLING COIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 10851.58000 |
798 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTLOUNGE COOLING COIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70525 |
799 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTLOUNGE COOLING COIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70525 |
800 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTLOUNGE COOLING COIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70525 |
801 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTLOUNGE COOLING COIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70525 |
802 | AirLoopHVAC:UnitarySystem | SAC_FRONTLOUNGE | User-Specified Nominal Cooling Capacity [W] | 21703.16000 |
803 | AirLoopHVAC:UnitarySystem | SAC_FRONTLOUNGE | Design Size Nominal Heating Capacity [W] | 25636.06962 |
804 | AirLoopHVAC:UnitarySystem | SAC_FRONTLOUNGE | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
805 | AirLoopHVAC:UnitarySystem | SAC_FRONTLOUNGE | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
806 | Fan:SystemModel | SAC_FL_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.97800 |
807 | Fan:SystemModel | SAC_FL_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 1082.79854 |
808 | Coil:Heating:Fuel | SAC_FRONTLOUNGE HEATING COIL | Design Size Nominal Capacity [W] | 25636.06962 |
809 | Controller:OutdoorAir | SAC_MEETINGROOM OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.46693 |
810 | Controller:OutdoorAir | SAC_MEETINGROOM OA CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.12637 |
811 | AirLoopHVAC:UnitarySystem | SAC_MEETINGROOM | Design Size Supply Air Flow Rate [m3/s] | 0.46693 |
812 | AirLoopHVAC:UnitarySystem | SAC_MEETINGROOM | Design Size Heating Supply Air Flow Rate [m3/s] | 0.46693 |
813 | AirLoopHVAC:UnitarySystem | SAC_MEETINGROOM | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.46693 |
814 | AirLoopHVAC:UnitarySystem | SAC_MEETINGROOM | Design Size No Load Supply Air Flow Rate [m3/s] | 0.46693 |
815 | Coil:Cooling:DX:MultiSpeed | SAC_MEETINGROOM COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.46693 |
816 | Coil:Cooling:DX:MultiSpeed | SAC_MEETINGROOM COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.23347 |
817 | Coil:Cooling:DX:MultiSpeed | SAC_MEETINGROOM COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.31129 |
818 | Coil:Cooling:DX:MultiSpeed | SAC_MEETINGROOM COOLING COIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 10975.67077 |
819 | Coil:Cooling:DX:MultiSpeed | SAC_MEETINGROOM COOLING COIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 11314.36000 |
820 | Coil:Cooling:DX:MultiSpeed | SAC_MEETINGROOM COOLING COIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 5657.18000 |
821 | Coil:Cooling:DX:MultiSpeed | SAC_MEETINGROOM COOLING COIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 5657.18000 |
822 | Coil:Cooling:DX:MultiSpeed | SAC_MEETINGROOM COOLING COIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.68216 |
823 | Coil:Cooling:DX:MultiSpeed | SAC_MEETINGROOM COOLING COIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.68216 |
824 | Coil:Cooling:DX:MultiSpeed | SAC_MEETINGROOM COOLING COIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.68216 |
825 | Coil:Cooling:DX:MultiSpeed | SAC_MEETINGROOM COOLING COIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.68216 |
826 | AirLoopHVAC:UnitarySystem | SAC_MEETINGROOM | User-Specified Nominal Cooling Capacity [W] | 11314.36000 |
827 | AirLoopHVAC:UnitarySystem | SAC_MEETINGROOM | Design Size Nominal Heating Capacity [W] | 12549.76204 |
828 | AirLoopHVAC:UnitarySystem | SAC_MEETINGROOM | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
829 | AirLoopHVAC:UnitarySystem | SAC_MEETINGROOM | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
830 | Fan:SystemModel | SAC_MR_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.46693 |
831 | Fan:SystemModel | SAC_MR_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 523.01269 |
832 | Coil:Heating:Fuel | SAC_MEETINGROOM HEATING COIL | Design Size Nominal Capacity [W] | 12549.76204 |
833 | Controller:OutdoorAir | SAC_EXC_EMPLGE_RESTRM OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.13722 |
834 | Controller:OutdoorAir | SAC_EXC_EMPLGE_RESTRM OA CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 9.43861E-002 |
835 | AirLoopHVAC:UnitarySystem | SAC_EXC_EMPLGE_RESTRM | Design Size Supply Air Flow Rate [m3/s] | 1.13722 |
836 | AirLoopHVAC:UnitarySystem | SAC_EXC_EMPLGE_RESTRM | Design Size Heating Supply Air Flow Rate [m3/s] | 1.13722 |
837 | AirLoopHVAC:UnitarySystem | SAC_EXC_EMPLGE_RESTRM | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.13722 |
838 | AirLoopHVAC:UnitarySystem | SAC_EXC_EMPLGE_RESTRM | Design Size No Load Supply Air Flow Rate [m3/s] | 0.75056 |
839 | Coil:Cooling:DX:MultiSpeed | SAC_EXC_EMPLGE_RESTRM COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.13722 |
840 | Coil:Cooling:DX:MultiSpeed | SAC_EXC_EMPLGE_RESTRM COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.56861 |
841 | Coil:Cooling:DX:MultiSpeed | SAC_EXC_EMPLGE_RESTRM COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.75815 |
842 | Coil:Cooling:DX:MultiSpeed | SAC_EXC_EMPLGE_RESTRM COOLING COIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 20997.15732 |
843 | Coil:Cooling:DX:MultiSpeed | SAC_EXC_EMPLGE_RESTRM COOLING COIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 21919.30000 |
844 | Coil:Cooling:DX:MultiSpeed | SAC_EXC_EMPLGE_RESTRM COOLING COIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 10959.65000 |
845 | Coil:Cooling:DX:MultiSpeed | SAC_EXC_EMPLGE_RESTRM COOLING COIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 10959.65000 |
846 | Coil:Cooling:DX:MultiSpeed | SAC_EXC_EMPLGE_RESTRM COOLING COIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.74675 |
847 | Coil:Cooling:DX:MultiSpeed | SAC_EXC_EMPLGE_RESTRM COOLING COIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.74675 |
848 | Coil:Cooling:DX:MultiSpeed | SAC_EXC_EMPLGE_RESTRM COOLING COIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.74675 |
849 | Coil:Cooling:DX:MultiSpeed | SAC_EXC_EMPLGE_RESTRM COOLING COIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.74675 |
850 | AirLoopHVAC:UnitarySystem | SAC_EXC_EMPLGE_RESTRM | User-Specified Nominal Cooling Capacity [W] | 21919.30000 |
851 | AirLoopHVAC:UnitarySystem | SAC_EXC_EMPLGE_RESTRM | Design Size Nominal Heating Capacity [W] | 25733.91927 |
852 | AirLoopHVAC:UnitarySystem | SAC_EXC_EMPLGE_RESTRM | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
853 | AirLoopHVAC:UnitarySystem | SAC_EXC_EMPLGE_RESTRM | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 0.15386 |
854 | Fan:SystemModel | SAC_EXC_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.13722 |
855 | Fan:SystemModel | SAC_EXC_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 1259.08049 |
856 | Coil:Heating:Fuel | SAC_EXC_EMPLGE_RESTRM HEATING COIL | Design Size Nominal Capacity [W] | 25733.91927 |
857 | PlantLoop | SHWSYSSHOWER | Maximum Loop Flow Rate [m3/s] | 1.79949E-004 |
858 | PlantLoop | SHWSYSSHOWER | Plant Loop Volume [m3] | 2.15939E-002 |
859 | Pump:ConstantSpeed | SHWSYSSHOWER PUMP | Design Flow Rate [m3/s] | 1.79949E-004 |
860 | Pump:ConstantSpeed | SHWSYSSHOWER PUMP | Design Power Consumption [W] | 8.11290 |
861 | WaterHeater:Mixed | SHWSYSSHOWER WATER HEATER | Use Side Design Flow Rate [m3/s] | 1.79949E-004 |
862 | PlantLoop | SHWSYSLAUNDRY | Maximum Loop Flow Rate [m3/s] | 1.29330E-004 |
863 | PlantLoop | SHWSYSLAUNDRY | Plant Loop Volume [m3] | 1.55196E-002 |
864 | Pump:ConstantSpeed | SHWSYSLAUNDRY PUMP | Design Flow Rate [m3/s] | 1.29330E-004 |
865 | Pump:ConstantSpeed | SHWSYSLAUNDRY PUMP | Design Power Consumption [W] | 5.52692E-007 |
866 | WaterHeater:Mixed | SHWSYSLAUNDRY WATER HEATER | Use Side Design Flow Rate [m3/s] | 1.29330E-004 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR1 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
2 | Coil:Cooling:DX:SingleSpeed | 101 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
3 | Coil:Cooling:DX:SingleSpeed | 102 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
4 | Coil:Cooling:DX:SingleSpeed | 103 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
5 | Coil:Cooling:DX:SingleSpeed | 104 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
6 | Coil:Cooling:DX:SingleSpeed | 105 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
7 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR2 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
8 | Coil:Cooling:DX:SingleSpeed | 201 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
9 | Coil:Cooling:DX:SingleSpeed | 202_205 PTAC COOLING COIL | 10147.8 | 3.20 | 10.92 | 11.57 | 10.93 |
10 | Coil:Cooling:DX:SingleSpeed | 206_208 PTAC COOLING COIL | 7610.9 | 3.20 | 10.92 | 11.57 | 10.93 |
11 | Coil:Cooling:DX:SingleSpeed | 209_212 PTAC COOLING COIL | 10147.8 | 3.20 | 10.92 | 11.57 | 10.93 |
12 | Coil:Cooling:DX:SingleSpeed | 213 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
13 | Coil:Cooling:DX:SingleSpeed | 214 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
14 | Coil:Cooling:DX:SingleSpeed | 215_218 PTAC COOLING COIL | 10147.8 | 3.20 | 10.92 | 11.57 | 10.93 |
15 | Coil:Cooling:DX:SingleSpeed | 219 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
16 | Coil:Cooling:DX:SingleSpeed | 220_223 PTAC COOLING COIL | 10147.8 | 3.20 | 10.92 | 11.57 | 10.93 |
17 | Coil:Cooling:DX:SingleSpeed | 224 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
18 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR3 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
19 | Coil:Cooling:DX:SingleSpeed | 301 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
20 | Coil:Cooling:DX:SingleSpeed | 302_305 PTAC COOLING COIL | 10147.8 | 3.20 | 10.92 | 11.57 | 10.93 |
21 | Coil:Cooling:DX:SingleSpeed | 306_308 PTAC COOLING COIL | 7610.9 | 3.20 | 10.92 | 11.57 | 10.93 |
22 | Coil:Cooling:DX:SingleSpeed | 309_312 PTAC COOLING COIL | 10147.8 | 3.20 | 10.92 | 11.57 | 10.93 |
23 | Coil:Cooling:DX:SingleSpeed | 313 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
24 | Coil:Cooling:DX:SingleSpeed | 314 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
25 | Coil:Cooling:DX:SingleSpeed | 315_318 PTAC COOLING COIL | 10147.8 | 3.20 | 10.92 | 11.57 | 10.93 |
26 | Coil:Cooling:DX:SingleSpeed | 319 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
27 | Coil:Cooling:DX:SingleSpeed | 320_323 PTAC COOLING COIL | 10147.8 | 3.20 | 10.92 | 11.57 | 10.93 |
28 | Coil:Cooling:DX:SingleSpeed | 324 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
29 | Coil:Cooling:DX:SingleSpeed | CORRIDORFLR4 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
30 | Coil:Cooling:DX:SingleSpeed | 401 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
31 | Coil:Cooling:DX:SingleSpeed | 402_405 PTAC COOLING COIL | 10147.8 | 3.20 | 10.92 | 11.57 | 10.93 |
32 | Coil:Cooling:DX:SingleSpeed | 406_408 PTAC COOLING COIL | 7610.9 | 3.20 | 10.92 | 11.57 | 10.93 |
33 | Coil:Cooling:DX:SingleSpeed | 409_412 PTAC COOLING COIL | 10147.8 | 3.20 | 10.92 | 11.57 | 10.93 |
34 | Coil:Cooling:DX:SingleSpeed | 413 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
35 | Coil:Cooling:DX:SingleSpeed | 414 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
36 | Coil:Cooling:DX:SingleSpeed | 415_418 PTAC COOLING COIL | 10147.8 | 3.20 | 10.92 | 11.57 | 10.93 |
37 | Coil:Cooling:DX:SingleSpeed | 419 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
38 | Coil:Cooling:DX:SingleSpeed | 420_423 PTAC COOLING COIL | 10147.8 | 3.20 | 10.92 | 11.57 | 10.93 |
39 | Coil:Cooling:DX:SingleSpeed | 424 PTAC COOLING COIL | 2537.0 | 3.20 | 10.92 | 11.57 | 10.93 |
40 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTOFFICE COOLING COIL | 8218.7 | 12.33 | |||
41 | Coil:Cooling:DX:MultiSpeed | SAC_FRONTLOUNGE COOLING COIL | 20943.4 | 16.38 | |||
42 | Coil:Cooling:DX:MultiSpeed | SAC_MEETINGROOM COOLING COIL | 10951.5 | 46.77 | |||
43 | Coil:Cooling:DX:MultiSpeed | SAC_EXC_EMPLGE_RESTRM COOLING COIL | 21036.4 | 33.37 |
Zone Name | # Surfaces | |
1 | REARSTAIRSFLR1 | 7 |
2 | CORRIDORFLR1 | 33 |
3 | REARSTORAGEFLR1 | 6 |
4 | FRONTLOUNGEFLR1 | 12 |
5 | RESTROOMFLR1 | 6 |
6 | MEETINGROOMFLR1 | 10 |
7 | MECHANICALROOMFLR1 | 6 |
8 | GUESTROOM101 | 7 |
9 | GUESTROOM102 | 7 |
10 | GUESTROOM103 | 7 |
11 | GUESTROOM104 | 7 |
12 | GUESTROOM105 | 7 |
13 | EMPLOYEELOUNGEFLR1 | 7 |
14 | LAUNDRYROOMFLR1 | 10 |
15 | ELEVATORCOREFLR1 | 6 |
16 | EXERCISECENTERFLR1 | 7 |
17 | FRONTOFFICEFLR1 | 11 |
18 | FRONTSTAIRSFLR1 | 7 |
19 | FRONTSTORAGEFLR1 | 6 |
20 | REARSTAIRSFLR2 | 6 |
21 | CORRIDORFLR2 | 24 |
22 | REARSTORAGEFLR2 | 6 |
23 | GUESTROOM201 | 7 |
24 | GUESTROOM202_205 | 10 |
25 | GUESTROOM206_208 | 11 |
26 | GUESTROOM209_212 | 13 |
27 | GUESTROOM213 | 7 |
28 | GUESTROOM214 | 7 |
29 | GUESTROOM215_218 | 12 |
30 | ELEVATORCOREFLR2 | 6 |
31 | GUESTROOM219 | 7 |
32 | GUESTROOM220_223 | 11 |
33 | GUESTROOM224 | 7 |
34 | FRONTSTORAGEFLR2 | 6 |
35 | FRONTSTAIRSFLR2 | 6 |
36 | REARSTAIRSFLR3 | 6 |
37 | CORRIDORFLR3 | 24 |
38 | REARSTORAGEFLR3 | 6 |
39 | GUESTROOM301 | 7 |
40 | GUESTROOM302_305 | 10 |
41 | GUESTROOM306_308 | 9 |
42 | GUESTROOM309_312 | 10 |
43 | GUESTROOM313 | 7 |
44 | GUESTROOM314 | 7 |
45 | GUESTROOM315_318 | 10 |
46 | ELEVATORCOREFLR3 | 6 |
47 | GUESTROOM319 | 7 |
48 | GUESTROOM320_323 | 10 |
49 | GUESTROOM324 | 7 |
50 | FRONTSTORAGEFLR3 | 6 |
51 | FRONTSTAIRSFLR3 | 6 |
52 | REARSTAIRSFLR4 | 6 |
53 | CORRIDORFLR4 | 24 |
54 | REARSTORAGEFLR4 | 6 |
55 | GUESTROOM401 | 7 |
56 | GUESTROOM402_405 | 10 |
57 | GUESTROOM406_408 | 9 |
58 | GUESTROOM409_412 | 10 |
59 | GUESTROOM413 | 7 |
60 | GUESTROOM414 | 7 |
61 | GUESTROOM415_418 | 10 |
62 | ELEVATORCOREFLR4 | 6 |
63 | GUESTROOM419 | 7 |
64 | GUESTROOM420_423 | 10 |
65 | GUESTROOM424 | 7 |
66 | FRONTSTORAGEFLR4 | 6 |
67 | FRONTSTAIRSFLR4 | 6 |
Number of Shading Surfaces | # Surfaces | |
1 | Number of Shading Surfaces | 2 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | W_REARSTAIRSFLR1_2_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | W_REARSTAIRSFLR1_3_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 6.23 | 8.18 | 6.23 | 180.00 | 90.00 | 2.44 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | W_REARSTAIRSFLR1_3_0_0_DOOR | Door | W_REARSTAIRSFLR1_3_0_0 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
4 | P_REARSTAIRSFLR1_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_GUESTROOM104_10002_0_10001 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
5 | P_REARSTAIRSFLR1_5_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 8.18 | 8.18 | 8.18 | 0.00 | 90.00 | 2.44 | 3.35 | 0.00 | P_CORRIDORFLR1_10003_0_10002 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
6 | S_REARSTAIRSFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_REARSTAIRSFLR1_0_0_0_FFACTOR | 0.750 | 0.634 | 20.07 | 20.07 | 20.07 | 180.00 | 180.00 | 2.44 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
7 | C_REARSTAIRSFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 20.07 | 20.07 | 20.07 | 0.00 | 0.00 | 2.44 | 8.23 | 0.00 | F_REARSTAIRSFLR2_10001_0_10000 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
8 | P_CORRIDORFLR1_10003_0_10002 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 8.18 | 8.18 | 8.18 | 180.00 | 90.00 | 2.44 | 3.35 | 0.00 | P_REARSTAIRSFLR1_5_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
9 | W_CORRIDORFLR1_2_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 3.44 | 6.13 | 3.44 | 270.00 | 90.00 | 1.83 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | W_CORRIDORFLR1_2_0_0_0_0 | Window | W_CORRIDORFLR1_2_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 2.69 | 2.69 | 2.69 | 270.00 | 90.00 | 1.14 | 2.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
11 | P_CORRIDORFLR1_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 180.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_GUESTROOM104_10007_0_10005 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | P_CORRIDORFLR1_5_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 180.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_GUESTROOM105_10008_0_10006 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
13 | P_CORRIDORFLR1_6_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 180.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_EMPLOYEELOUNGEFLR1_10009_0_10007 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
14 | P_CORRIDORFLR1_7_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 39.86 | 39.86 | 39.86 | 180.00 | 90.00 | 11.89 | 3.35 | 0.00 | P_LAUNDRYROOMFLR1_10010_0_10008 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
15 | P_CORRIDORFLR1_8_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.13 | 6.13 | 6.13 | 180.00 | 90.00 | 1.83 | 3.35 | 0.00 | P_ELEVATORCOREFLR1_10011_0_10009 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | P_CORRIDORFLR1_9_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_ELEVATORCOREFLR1_10012_0_10010 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | W_CORRIDORFLR1_10_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 8.27 | 10.22 | 8.27 | 180.00 | 90.00 | 3.05 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | W_CORRIDORFLR1_10_0_0_DOOR | Door | W_CORRIDORFLR1_10_0_0 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
19 | P_CORRIDORFLR1_11_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_EXERCISECENTERFLR1_10013_0_10011 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | P_CORRIDORFLR1_12_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 180.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_EXERCISECENTERFLR1_10014_0_10012 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | P_CORRIDORFLR1_13_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 53.14 | 53.14 | 53.14 | 180.00 | 90.00 | 15.85 | 3.35 | 0.00 | P_FRONTOFFICEFLR1_10015_0_10013 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | P_CORRIDORFLR1_14_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 5.11 | 5.11 | 5.11 | 180.00 | 90.00 | 1.52 | 3.35 | 0.00 | P_FRONTSTORAGEFLR1_10016_0_10014 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
23 | P_CORRIDORFLR1_15_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 8.18 | 8.18 | 8.18 | 180.00 | 90.00 | 2.44 | 3.35 | 0.00 | P_FRONTSTAIRSFLR1_10017_0_10015 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
24 | W_CORRIDORFLR1_16_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 1.69 | 6.13 | 1.69 | 90.00 | 90.00 | 1.83 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.96 | 3.65E-002 | 4 | ||
25 | D_CORRIDORFLR1_16_0_0_0_0 | Window | W_CORRIDORFLR1_16_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 4.44 | 4.44 | 4.44 | 90.00 | 90.00 | 1.82 | 2.43 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.83 | 0.17 | 4 |
26 | P_CORRIDORFLR1_17_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.43 | 66.43 | 66.43 | 0.00 | 90.00 | 19.81 | 3.35 | 0.00 | P_FRONTLOUNGEFLR1_10018_0_10016 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
27 | P_CORRIDORFLR1_18_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_RESTROOMFLR1_10019_0_10017 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
28 | P_CORRIDORFLR1_19_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_RESTROOMFLR1_10020_0_10018 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
29 | W_CORRIDORFLR1_20_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 7.53 | 10.22 | 7.53 | 0.00 | 90.00 | 3.05 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
30 | W_CORRIDORFLR1_20_0_0_0_0 | Window | W_CORRIDORFLR1_20_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 2.69 | 2.69 | 2.69 | 0.00 | 90.00 | 1.14 | 2.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
31 | P_CORRIDORFLR1_21_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_MEETINGROOMFLR1_10021_0_10019 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
32 | P_CORRIDORFLR1_22_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 32.70 | 32.70 | 32.70 | 0.00 | 90.00 | 9.75 | 3.35 | 0.00 | P_MEETINGROOMFLR1_10022_0_10020 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | P_CORRIDORFLR1_23_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_MECHANICALROOMFLR1_10023_0_10021 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
34 | P_CORRIDORFLR1_24_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_GUESTROOM101_10024_0_10022 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | P_CORRIDORFLR1_25_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_GUESTROOM102_10025_0_10023 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
36 | P_CORRIDORFLR1_26_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_GUESTROOM103_10026_0_10024 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
37 | P_CORRIDORFLR1_27_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 8.18 | 8.18 | 8.18 | 0.00 | 90.00 | 2.44 | 3.35 | 0.00 | P_REARSTORAGEFLR1_10027_0_10025 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
38 | S_CORRIDORFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_CORRIDORFLR1_0_0_0_FFACTOR | 8.294E-002 | 8.130E-002 | 150.51 | 150.51 | 150.51 | 180.00 | 180.00 | 12.27 | 12.27 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 12 | ||
39 | C_CORRIDORFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 125.42 | 125.42 | 125.42 | 0.00 | 0.00 | 11.20 | 11.20 | 0.00 | F_CORRIDORFLR2_10004_0_10003 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
40 | C_CORRIDORFLR1_1_1_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 25.09 | 25.09 | 25.09 | 0.00 | 0.00 | 3.05 | 8.23 | 0.00 | F_GUESTROOM206_208_10005_0_10004 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
41 | P_REARSTORAGEFLR1_10027_0_10025 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 8.18 | 8.18 | 8.18 | 180.00 | 90.00 | 2.44 | 3.35 | 0.00 | P_CORRIDORFLR1_27_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
42 | W_REARSTORAGEFLR1_2_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | P_REARSTORAGEFLR1_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_GUESTROOM103_10030_0_10027 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
44 | W_REARSTORAGEFLR1_5_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 8.18 | 8.18 | 8.18 | 0.00 | 90.00 | 2.44 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
45 | S_REARSTORAGEFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_REARSTORAGEFLR1_0_0_0_FFACTOR | 0.750 | 0.634 | 20.07 | 20.07 | 20.07 | 180.00 | 180.00 | 2.44 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
46 | C_REARSTORAGEFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 20.07 | 20.07 | 20.07 | 0.00 | 0.00 | 2.44 | 8.23 | 0.00 | F_REARSTORAGEFLR2_10028_0_10026 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
47 | P_FRONTLOUNGEFLR1_10018_0_10016 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.43 | 66.43 | 66.43 | 180.00 | 90.00 | 19.81 | 3.35 | 0.00 | P_CORRIDORFLR1_17_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
48 | P_FRONTLOUNGEFLR1_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_RESTROOMFLR1_10033_0_10030 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | W_FRONTLOUNGEFLR1_4_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.68 | 0.32 | 4 | ||
50 | W_FRONTLOUNGEFLR1_5_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 51.60 | 66.43 | 51.60 | 0.00 | 90.00 | 19.81 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | W_FRONTLOUNGEFLR1_5_0_0_0_0 | Window | W_FRONTLOUNGEFLR1_5_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 2.97 | 2.97 | 2.97 | 0.00 | 90.00 | 2.05 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
52 | W_FRONTLOUNGEFLR1_5_0_0_0_1 | Window | W_FRONTLOUNGEFLR1_5_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 2.97 | 2.97 | 2.97 | 0.00 | 90.00 | 2.05 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
53 | W_FRONTLOUNGEFLR1_5_0_0_0_2 | Window | W_FRONTLOUNGEFLR1_5_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 2.97 | 2.97 | 2.97 | 0.00 | 90.00 | 2.05 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
54 | W_FRONTLOUNGEFLR1_5_0_0_0_3 | Window | W_FRONTLOUNGEFLR1_5_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 2.97 | 2.97 | 2.97 | 0.00 | 90.00 | 2.05 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
55 | W_FRONTLOUNGEFLR1_5_0_0_0_4 | Window | W_FRONTLOUNGEFLR1_5_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 2.97 | 2.97 | 2.97 | 0.00 | 90.00 | 2.05 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
56 | S_FRONTLOUNGEFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_FRONTLOUNGEFLR1_0_0_0_FFACTOR | 0.225 | 0.213 | 163.06 | 163.06 | 163.06 | 180.00 | 180.00 | 19.81 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
57 | C_FRONTLOUNGEFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM201_10031_0_10028 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
58 | C_FRONTLOUNGEFLR1_1_1_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 130.45 | 130.45 | 130.45 | 0.00 | 0.00 | 15.85 | 8.23 | 0.00 | F_GUESTROOM202_205_10032_0_10029 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | P_RESTROOMFLR1_10019_0_10017 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 180.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_CORRIDORFLR1_18_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | P_RESTROOMFLR1_10020_0_10018 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_CORRIDORFLR1_19_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | P_RESTROOMFLR1_10033_0_10030 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_FRONTLOUNGEFLR1_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
62 | W_RESTROOMFLR1_5_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 13.29 | 13.29 | 13.29 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | S_RESTROOMFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_RESTROOMFLR1_0_0_0_FFACTOR | 0.157 | 0.151 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
64 | C_RESTROOMFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM206_208_10035_0_10031 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
65 | P_MEETINGROOMFLR1_10021_0_10019 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_CORRIDORFLR1_21_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
66 | P_MEETINGROOMFLR1_10022_0_10020 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 32.70 | 32.70 | 32.70 | 180.00 | 90.00 | 9.75 | 3.35 | 0.00 | P_CORRIDORFLR1_22_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
67 | P_MEETINGROOMFLR1_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_MECHANICALROOMFLR1_10041_0_10034 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
68 | W_MEETINGROOMFLR1_5_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 27.77 | 32.70 | 27.77 | 0.00 | 90.00 | 9.75 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | W_MEETINGROOMFLR1_5_0_0_0_0 | Window | W_MEETINGROOMFLR1_5_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | W_MEETINGROOMFLR1_5_0_0_0_1 | Window | W_MEETINGROOMFLR1_5_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
71 | W_MEETINGROOMFLR1_5_0_0_0_2 | Window | W_MEETINGROOMFLR1_5_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
72 | S_MEETINGROOMFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_MEETINGROOMFLR1_0_0_0_FFACTOR | 0.157 | 0.151 | 80.27 | 80.27 | 80.27 | 180.00 | 180.00 | 9.75 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
73 | C_MEETINGROOMFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 47.66 | 47.66 | 47.66 | 0.00 | 0.00 | 5.79 | 8.23 | 0.00 | F_GUESTROOM206_208_10039_0_10032 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
74 | C_MEETINGROOMFLR1_1_1_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM209_212_10040_0_10033 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
75 | P_MECHANICALROOMFLR1_10023_0_10021 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 180.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_CORRIDORFLR1_23_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
76 | P_MECHANICALROOMFLR1_10041_0_10034 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_MEETINGROOMFLR1_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
77 | P_MECHANICALROOMFLR1_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_GUESTROOM101_10045_0_10036 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
78 | W_MECHANICALROOMFLR1_5_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 13.29 | 13.29 | 13.29 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
79 | S_MECHANICALROOMFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_MECHANICALROOMFLR1_0_0_0_FFACTOR | 0.157 | 0.151 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
80 | C_MECHANICALROOMFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM209_212_10044_0_10035 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
81 | P_GUESTROOM101_10024_0_10022 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 180.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_CORRIDORFLR1_24_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
82 | P_GUESTROOM101_10045_0_10036 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_MECHANICALROOMFLR1_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
83 | P_GUESTROOM101_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_GUESTROOM102_10049_0_10038 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
84 | W_GUESTROOM101_5_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 11.64 | 13.29 | 11.64 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
85 | W_GUESTROOM101_5_0_0_0_0 | Window | W_GUESTROOM101_5_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
86 | S_GUESTROOM101_0_0_0 | Floor | CTF - ConductionTransferFunction | S_GUESTROOM101_0_0_0_FFACTOR | 0.157 | 0.151 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
87 | C_GUESTROOM101_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM209_212_10048_0_10037 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
88 | P_GUESTROOM102_10025_0_10023 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 180.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_CORRIDORFLR1_25_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
89 | P_GUESTROOM102_10049_0_10038 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_GUESTROOM101_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
90 | P_GUESTROOM102_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_GUESTROOM103_10053_0_10040 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
91 | W_GUESTROOM102_5_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 11.64 | 13.29 | 11.64 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
92 | W_GUESTROOM102_5_0_0_0_0 | Window | W_GUESTROOM102_5_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
93 | S_GUESTROOM102_0_0_0 | Floor | CTF - ConductionTransferFunction | S_GUESTROOM102_0_0_0_FFACTOR | 0.157 | 0.151 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
94 | C_GUESTROOM102_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM209_212_10052_0_10039 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
95 | P_GUESTROOM103_10026_0_10024 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 180.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_CORRIDORFLR1_26_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
96 | P_GUESTROOM103_10030_0_10027 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_REARSTORAGEFLR1_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
97 | P_GUESTROOM103_10053_0_10040 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_GUESTROOM102_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
98 | W_GUESTROOM103_5_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 11.64 | 13.29 | 11.64 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
99 | W_GUESTROOM103_5_0_0_0_0 | Window | W_GUESTROOM103_5_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
100 | S_GUESTROOM103_0_0_0 | Floor | CTF - ConductionTransferFunction | S_GUESTROOM103_0_0_0_FFACTOR | 0.157 | 0.151 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
101 | C_GUESTROOM103_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM213_10056_0_10041 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
102 | P_GUESTROOM104_10002_0_10001 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_REARSTAIRSFLR1_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
103 | P_GUESTROOM104_10007_0_10005 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_CORRIDORFLR1_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
104 | W_GUESTROOM104_3_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 11.64 | 13.29 | 11.64 | 180.00 | 90.00 | 3.96 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | W_GUESTROOM104_3_0_0_0_0 | Window | W_GUESTROOM104_3_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
106 | P_GUESTROOM104_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_GUESTROOM105_10062_0_10043 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
107 | S_GUESTROOM104_0_0_0 | Floor | CTF - ConductionTransferFunction | S_GUESTROOM104_0_0_0_FFACTOR | 0.157 | 0.151 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
108 | C_GUESTROOM104_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM214_10060_0_10042 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
109 | P_GUESTROOM105_10008_0_10006 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_CORRIDORFLR1_5_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
110 | P_GUESTROOM105_10062_0_10043 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_GUESTROOM104_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
111 | W_GUESTROOM105_3_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 11.64 | 13.29 | 11.64 | 180.00 | 90.00 | 3.96 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
112 | W_GUESTROOM105_3_0_0_0_0 | Window | W_GUESTROOM105_3_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
113 | P_GUESTROOM105_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_EMPLOYEELOUNGEFLR1_10066_0_10045 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
114 | S_GUESTROOM105_0_0_0 | Floor | CTF - ConductionTransferFunction | S_GUESTROOM105_0_0_0_FFACTOR | 0.157 | 0.151 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
115 | C_GUESTROOM105_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM215_218_10064_0_10044 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
116 | P_EMPLOYEELOUNGEFLR1_10009_0_10007 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_CORRIDORFLR1_6_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
117 | P_EMPLOYEELOUNGEFLR1_10066_0_10045 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_GUESTROOM105_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
118 | W_EMPLOYEELOUNGEFLR1_3_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 11.64 | 13.29 | 11.64 | 180.00 | 90.00 | 3.96 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
119 | W_EMPLOYEELOUNGEFLR1_3_0_0_0_0 | Window | W_EMPLOYEELOUNGEFLR1_3_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
120 | P_EMPLOYEELOUNGEFLR1_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_LAUNDRYROOMFLR1_10070_0_10047 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
121 | S_EMPLOYEELOUNGEFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_EMPLOYEELOUNGEFLR1_0_0_0_FFACTOR | 0.157 | 0.151 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
122 | C_EMPLOYEELOUNGEFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM215_218_10068_0_10046 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
123 | P_LAUNDRYROOMFLR1_10010_0_10008 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 39.86 | 39.86 | 39.86 | 0.00 | 90.00 | 11.89 | 3.35 | 0.00 | P_CORRIDORFLR1_7_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
124 | P_LAUNDRYROOMFLR1_10070_0_10047 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_EMPLOYEELOUNGEFLR1_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
125 | W_LAUNDRYROOMFLR1_3_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 34.92 | 39.86 | 34.92 | 180.00 | 90.00 | 11.89 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
126 | W_LAUNDRYROOMFLR1_3_0_0_0_0 | Window | W_LAUNDRYROOMFLR1_3_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
127 | W_LAUNDRYROOMFLR1_3_0_0_0_1 | Window | W_LAUNDRYROOMFLR1_3_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
128 | W_LAUNDRYROOMFLR1_3_0_0_0_2 | Window | W_LAUNDRYROOMFLR1_3_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
129 | P_LAUNDRYROOMFLR1_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_ELEVATORCOREFLR1_10075_0_10050 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
130 | S_LAUNDRYROOMFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_LAUNDRYROOMFLR1_0_0_0_FFACTOR | 0.157 | 0.151 | 97.83 | 97.83 | 97.83 | 180.00 | 180.00 | 11.89 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
131 | C_LAUNDRYROOMFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 65.22 | 65.22 | 65.22 | 0.00 | 0.00 | 7.92 | 8.23 | 0.00 | F_GUESTROOM215_218_10072_0_10048 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
132 | C_LAUNDRYROOMFLR1_1_1_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM219_10073_0_10049 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
133 | P_ELEVATORCOREFLR1_10011_0_10009 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.13 | 6.13 | 6.13 | 0.00 | 90.00 | 1.83 | 3.35 | 0.00 | P_CORRIDORFLR1_8_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
134 | P_ELEVATORCOREFLR1_10012_0_10010 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_CORRIDORFLR1_9_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
135 | P_ELEVATORCOREFLR1_10075_0_10050 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_LAUNDRYROOMFLR1_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
136 | W_ELEVATORCOREFLR1_3_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 6.13 | 6.13 | 6.13 | 180.00 | 90.00 | 1.83 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
137 | S_ELEVATORCOREFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_ELEVATORCOREFLR1_0_0_0_FFACTOR | 0.157 | 0.151 | 15.05 | 15.05 | 15.05 | 180.00 | 180.00 | 1.83 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
138 | C_ELEVATORCOREFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 15.05 | 15.05 | 15.05 | 0.00 | 0.00 | 1.83 | 8.23 | 0.00 | F_ELEVATORCOREFLR2_10077_0_10051 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
139 | P_EXERCISECENTERFLR1_10013_0_10011 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_CORRIDORFLR1_11_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
140 | P_EXERCISECENTERFLR1_10014_0_10012 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.29 | 13.29 | 13.29 | 0.00 | 90.00 | 3.96 | 3.35 | 0.00 | P_CORRIDORFLR1_12_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
141 | W_EXERCISECENTERFLR1_3_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 11.64 | 13.29 | 11.64 | 180.00 | 90.00 | 3.96 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
142 | W_EXERCISECENTERFLR1_3_0_0_0_0 | Window | W_EXERCISECENTERFLR1_3_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
143 | P_EXERCISECENTERFLR1_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_FRONTOFFICEFLR1_10083_0_10053 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
144 | S_EXERCISECENTERFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_EXERCISECENTERFLR1_0_0_0_FFACTOR | 0.157 | 0.151 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
145 | C_EXERCISECENTERFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM220_223_10081_0_10052 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
146 | P_FRONTOFFICEFLR1_10015_0_10013 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 53.14 | 53.14 | 53.14 | 0.00 | 90.00 | 15.85 | 3.35 | 0.00 | P_CORRIDORFLR1_13_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
147 | P_FRONTOFFICEFLR1_10083_0_10053 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_EXERCISECENTERFLR1_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
148 | W_FRONTOFFICEFLR1_3_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 46.56 | 53.14 | 46.56 | 180.00 | 90.00 | 15.85 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
149 | W_FRONTOFFICEFLR1_3_0_0_0_0 | Window | W_FRONTOFFICEFLR1_3_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
150 | W_FRONTOFFICEFLR1_3_0_0_0_1 | Window | W_FRONTOFFICEFLR1_3_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
151 | W_FRONTOFFICEFLR1_3_0_0_0_2 | Window | W_FRONTOFFICEFLR1_3_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
152 | W_FRONTOFFICEFLR1_3_0_0_0_3 | Window | W_FRONTOFFICEFLR1_3_0_0 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
153 | P_FRONTOFFICEFLR1_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_FRONTSTORAGEFLR1_10088_0_10056 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
154 | S_FRONTOFFICEFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_FRONTOFFICEFLR1_0_0_0_FFACTOR | 0.157 | 0.151 | 130.44 | 130.44 | 130.44 | 180.00 | 180.00 | 15.85 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
155 | C_FRONTOFFICEFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 97.83 | 97.83 | 97.83 | 0.00 | 0.00 | 11.89 | 8.23 | 0.00 | F_GUESTROOM220_223_10085_0_10054 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
156 | C_FRONTOFFICEFLR1_1_1_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM224_10086_0_10055 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
157 | P_FRONTSTAIRSFLR1_10017_0_10015 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 8.18 | 8.18 | 8.18 | 0.00 | 90.00 | 2.44 | 3.35 | 0.00 | P_CORRIDORFLR1_15_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
158 | P_FRONTSTAIRSFLR1_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_FRONTSTORAGEFLR1_10091_0_10058 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
159 | W_FRONTSTAIRSFLR1_3_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 6.22 | 8.18 | 6.22 | 180.00 | 90.00 | 2.44 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
160 | W_FRONTSTAIRSFLR1_3_0_0_DOOR | Door | W_FRONTSTAIRSFLR1_3_0_0 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
161 | W_FRONTSTAIRSFLR1_4_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.68 | 0.32 | 4 | ||
162 | S_FRONTSTAIRSFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_FRONTSTAIRSFLR1_0_0_0_FFACTOR | 0.750 | 0.634 | 20.07 | 20.07 | 20.07 | 180.00 | 180.00 | 2.44 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
163 | C_FRONTSTAIRSFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 20.07 | 20.07 | 20.07 | 0.00 | 0.00 | 2.44 | 8.23 | 0.00 | F_FRONTSTAIRSFLR2_10090_0_10057 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
164 | P_FRONTSTORAGEFLR1_10016_0_10014 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 5.11 | 5.11 | 5.11 | 0.00 | 90.00 | 1.52 | 3.35 | 0.00 | P_CORRIDORFLR1_14_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
165 | P_FRONTSTORAGEFLR1_10088_0_10056 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 270.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_FRONTOFFICEFLR1_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
166 | P_FRONTSTORAGEFLR1_10091_0_10058 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 27.59 | 27.59 | 27.59 | 90.00 | 90.00 | 8.23 | 3.35 | 0.00 | P_FRONTSTAIRSFLR1_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
167 | W_FRONTSTORAGEFLR1_3_0_0 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 5.11 | 5.11 | 5.11 | 180.00 | 90.00 | 1.52 | 3.35 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
168 | S_FRONTSTORAGEFLR1_0_0_0 | Floor | CTF - ConductionTransferFunction | S_FRONTSTORAGEFLR1_0_0_0_FFACTOR | 0.157 | 0.151 | 12.54 | 12.54 | 12.54 | 180.00 | 180.00 | 1.52 | 8.23 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
169 | C_FRONTSTORAGEFLR1_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 12.54 | 12.54 | 12.54 | 0.00 | 0.00 | 1.52 | 8.23 | 0.00 | F_FRONTSTORAGEFLR2_10093_0_10059 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
170 | W_REARSTAIRSFLR2_2_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
171 | W_REARSTAIRSFLR2_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
172 | P_REARSTAIRSFLR2_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM214_10099_0_10061 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
173 | P_REARSTAIRSFLR2_5_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 0.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_CORRIDORFLR2_10100_0_10062 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
174 | F_REARSTAIRSFLR2_10001_0_10000 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 20.07 | 20.07 | 20.07 | 180.00 | 180.00 | 2.44 | 8.23 | 0.00 | C_REARSTAIRSFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
175 | C_REARSTAIRSFLR2_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 20.07 | 20.07 | 20.07 | 0.00 | 0.00 | 2.44 | 8.23 | 0.00 | F_REARSTAIRSFLR3_10098_0_10060 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
176 | P_CORRIDORFLR2_10100_0_10062 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_REARSTAIRSFLR2_5_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
177 | W_CORRIDORFLR2_2_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 3.71 | 5.02 | 3.71 | 270.00 | 90.00 | 1.83 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
178 | W_CORRIDORFLR2_2_0_0_0_0 | Window | W_CORRIDORFLR2_2_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.31 | 1.31 | 1.31 | 270.00 | 90.00 | 0.92 | 1.42 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
179 | P_CORRIDORFLR2_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM214_10104_0_10064 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
180 | P_CORRIDORFLR2_5_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_GUESTROOM215_218_10105_0_10065 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
181 | P_CORRIDORFLR2_6_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM219_10106_0_10066 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
182 | P_CORRIDORFLR2_7_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 5.02 | 5.02 | 5.02 | 180.00 | 90.00 | 1.83 | 2.74 | 0.00 | P_ELEVATORCOREFLR2_10107_0_10067 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
183 | P_CORRIDORFLR2_8_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_ELEVATORCOREFLR2_10108_0_10068 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
184 | W_CORRIDORFLR2_9_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 8.36 | 8.36 | 8.36 | 180.00 | 90.00 | 3.05 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
185 | P_CORRIDORFLR2_10_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM220_223_10109_0_10069 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
186 | P_CORRIDORFLR2_11_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_GUESTROOM220_223_10110_0_10070 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
187 | P_CORRIDORFLR2_12_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM224_10111_0_10071 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
188 | P_CORRIDORFLR2_13_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 4.18 | 4.18 | 4.18 | 180.00 | 90.00 | 1.52 | 2.74 | 0.00 | P_FRONTSTORAGEFLR2_10112_0_10072 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
189 | P_CORRIDORFLR2_14_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_FRONTSTAIRSFLR2_10113_0_10073 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
190 | W_CORRIDORFLR2_15_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 3.71 | 5.02 | 3.71 | 90.00 | 90.00 | 1.83 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
191 | W_CORRIDORFLR2_15_0_0_0_0 | Window | W_CORRIDORFLR2_15_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.31 | 1.31 | 1.31 | 90.00 | 90.00 | 0.92 | 1.42 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
192 | P_CORRIDORFLR2_16_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM201_10114_0_10074 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
193 | P_CORRIDORFLR2_17_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_GUESTROOM202_205_10115_0_10075 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
194 | P_CORRIDORFLR2_18_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.12 | 35.12 | 35.12 | 0.00 | 90.00 | 12.80 | 2.74 | 0.00 | P_GUESTROOM206_208_10116_0_10076 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
195 | P_CORRIDORFLR2_19_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_GUESTROOM209_212_10117_0_10077 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
196 | P_CORRIDORFLR2_20_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM213_10118_0_10078 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
197 | P_CORRIDORFLR2_21_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 0.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_REARSTORAGEFLR2_10119_0_10079 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
198 | F_CORRIDORFLR2_10004_0_10003 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 125.42 | 125.42 | 125.42 | 180.00 | 180.00 | 11.20 | 11.20 | 0.00 | C_CORRIDORFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 8 | ||
199 | C_CORRIDORFLR2_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 125.42 | 125.42 | 125.42 | 0.00 | 0.00 | 11.20 | 11.20 | 0.00 | F_CORRIDORFLR3_10102_0_10063 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
200 | P_REARSTORAGEFLR2_10119_0_10079 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_CORRIDORFLR2_21_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
201 | W_REARSTORAGEFLR2_2_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
202 | P_REARSTORAGEFLR2_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM213_10123_0_10081 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
203 | W_REARSTORAGEFLR2_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 6.69 | 6.69 | 6.69 | 0.00 | 90.00 | 2.44 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
204 | F_REARSTORAGEFLR2_10028_0_10026 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 20.07 | 20.07 | 20.07 | 180.00 | 180.00 | 2.44 | 8.23 | 0.00 | C_REARSTORAGEFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
205 | C_REARSTORAGEFLR2_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 20.07 | 20.07 | 20.07 | 0.00 | 0.00 | 2.44 | 8.23 | 0.00 | F_REARSTORAGEFLR3_10121_0_10080 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
206 | P_GUESTROOM201_10114_0_10074 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR2_16_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
207 | P_GUESTROOM201_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM202_205_10126_0_10083 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
208 | W_GUESTROOM201_4_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
209 | W_GUESTROOM201_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
210 | W_GUESTROOM201_5_0_0_0_0 | Window | W_GUESTROOM201_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
211 | F_GUESTROOM201_10031_0_10028 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_FRONTLOUNGEFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
212 | C_GUESTROOM201_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM301_10125_0_10082 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
213 | P_GUESTROOM202_205_10115_0_10075 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_CORRIDORFLR2_17_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
214 | P_GUESTROOM202_205_10126_0_10083 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM201_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
215 | P_GUESTROOM202_205_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM206_208_10130_0_10085 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
216 | W_GUESTROOM202_205_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 36.90 | 43.48 | 36.90 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
217 | W_GUESTROOM202_205_5_0_0_0_0 | Window | W_GUESTROOM202_205_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
218 | W_GUESTROOM202_205_5_0_0_0_1 | Window | W_GUESTROOM202_205_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
219 | W_GUESTROOM202_205_5_0_0_0_2 | Window | W_GUESTROOM202_205_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
220 | W_GUESTROOM202_205_5_0_0_0_3 | Window | W_GUESTROOM202_205_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
221 | F_GUESTROOM202_205_10032_0_10029 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 130.45 | 130.45 | 130.45 | 180.00 | 180.00 | 15.85 | 8.23 | 0.00 | C_FRONTLOUNGEFLR1_1_1_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
222 | C_GUESTROOM202_205_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 130.45 | 130.45 | 130.45 | 0.00 | 0.00 | 15.85 | 8.23 | 0.00 | F_GUESTROOM302_305_10129_0_10084 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
223 | P_GUESTROOM206_208_10116_0_10076 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.12 | 35.12 | 35.12 | 180.00 | 90.00 | 12.80 | 2.74 | 0.00 | P_CORRIDORFLR2_18_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
224 | P_GUESTROOM206_208_10130_0_10085 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM202_205_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
225 | P_GUESTROOM206_208_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM209_212_10137_0_10087 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
226 | W_GUESTROOM206_208_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 28.42 | 35.12 | 28.42 | 0.00 | 90.00 | 12.80 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
227 | W_GUESTROOM206_208_5_0_0_0_0 | Window | W_GUESTROOM206_208_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
228 | W_GUESTROOM206_208_5_0_0_0_1 | Window | W_GUESTROOM206_208_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 3.41 | 3.41 | 3.41 | 0.00 | 90.00 | 2.36 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
229 | W_GUESTROOM206_208_5_0_0_0_2 | Window | W_GUESTROOM206_208_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
230 | F_GUESTROOM206_208_10005_0_10004 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 25.09 | 25.09 | 25.09 | 180.00 | 180.00 | 3.05 | 8.23 | 0.00 | C_CORRIDORFLR1_1_1_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
231 | F_GUESTROOM206_208_10035_0_10031 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_RESTROOMFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
232 | F_GUESTROOM206_208_10039_0_10032 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 47.66 | 47.66 | 47.66 | 180.00 | 180.00 | 5.79 | 8.23 | 0.00 | C_MEETINGROOMFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
233 | C_GUESTROOM206_208_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 105.36 | 105.36 | 105.36 | 0.00 | 0.00 | 12.80 | 8.23 | 0.00 | F_GUESTROOM306_308_10136_0_10086 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
234 | P_GUESTROOM209_212_10117_0_10077 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_CORRIDORFLR2_19_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
235 | P_GUESTROOM209_212_10137_0_10087 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM206_208_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
236 | P_GUESTROOM209_212_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM213_10145_0_10089 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
237 | W_GUESTROOM209_212_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 36.90 | 43.48 | 36.90 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
238 | W_GUESTROOM209_212_5_0_0_0_0 | Window | W_GUESTROOM209_212_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
239 | W_GUESTROOM209_212_5_0_0_0_1 | Window | W_GUESTROOM209_212_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
240 | W_GUESTROOM209_212_5_0_0_0_2 | Window | W_GUESTROOM209_212_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
241 | W_GUESTROOM209_212_5_0_0_0_3 | Window | W_GUESTROOM209_212_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
242 | F_GUESTROOM209_212_10040_0_10033 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_MEETINGROOMFLR1_1_1_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
243 | F_GUESTROOM209_212_10044_0_10035 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_MECHANICALROOMFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
244 | F_GUESTROOM209_212_10048_0_10037 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM101_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
245 | F_GUESTROOM209_212_10052_0_10039 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM102_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
246 | C_GUESTROOM209_212_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 130.45 | 130.45 | 130.45 | 0.00 | 0.00 | 15.85 | 8.23 | 0.00 | F_GUESTROOM309_312_10144_0_10088 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
247 | P_GUESTROOM213_10118_0_10078 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR2_20_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
248 | P_GUESTROOM213_10123_0_10081 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_REARSTORAGEFLR2_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
249 | P_GUESTROOM213_10145_0_10089 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM209_212_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
250 | W_GUESTROOM213_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
251 | W_GUESTROOM213_5_0_0_0_0 | Window | W_GUESTROOM213_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
252 | F_GUESTROOM213_10056_0_10041 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM103_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
253 | C_GUESTROOM213_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM313_10149_0_10090 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
254 | P_GUESTROOM214_10099_0_10061 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_REARSTAIRSFLR2_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
255 | P_GUESTROOM214_10104_0_10064 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR2_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
256 | W_GUESTROOM214_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
257 | W_GUESTROOM214_3_0_0_0_0 | Window | W_GUESTROOM214_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
258 | P_GUESTROOM214_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM215_218_10156_0_10092 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
259 | F_GUESTROOM214_10060_0_10042 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM104_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
260 | C_GUESTROOM214_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM314_10154_0_10091 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
261 | P_GUESTROOM215_218_10105_0_10065 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_CORRIDORFLR2_5_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
262 | P_GUESTROOM215_218_10156_0_10092 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM214_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
263 | W_GUESTROOM215_218_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 36.90 | 43.48 | 36.90 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
264 | W_GUESTROOM215_218_3_0_0_0_0 | Window | W_GUESTROOM215_218_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
265 | W_GUESTROOM215_218_3_0_0_0_1 | Window | W_GUESTROOM215_218_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
266 | W_GUESTROOM215_218_3_0_0_0_2 | Window | W_GUESTROOM215_218_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
267 | W_GUESTROOM215_218_3_0_0_0_3 | Window | W_GUESTROOM215_218_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
268 | P_GUESTROOM215_218_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM219_10163_0_10094 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
269 | F_GUESTROOM215_218_10064_0_10044 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM105_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
270 | F_GUESTROOM215_218_10068_0_10046 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_EMPLOYEELOUNGEFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
271 | F_GUESTROOM215_218_10072_0_10048 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 65.22 | 65.22 | 65.22 | 180.00 | 180.00 | 7.92 | 8.23 | 0.00 | C_LAUNDRYROOMFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
272 | C_GUESTROOM215_218_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 130.44 | 130.44 | 130.44 | 0.00 | 0.00 | 15.85 | 8.23 | 0.00 | F_GUESTROOM315_318_10161_0_10093 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
273 | P_ELEVATORCOREFLR2_10107_0_10067 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 5.02 | 5.02 | 5.02 | 0.00 | 90.00 | 1.83 | 2.74 | 0.00 | P_CORRIDORFLR2_7_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
274 | P_ELEVATORCOREFLR2_10108_0_10068 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_CORRIDORFLR2_8_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
275 | P_ELEVATORCOREFLR2_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM219_10167_0_10096 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
276 | W_ELEVATORCOREFLR2_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 5.02 | 5.02 | 5.02 | 180.00 | 90.00 | 1.83 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
277 | F_ELEVATORCOREFLR2_10077_0_10051 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 15.05 | 15.05 | 15.05 | 180.00 | 180.00 | 1.83 | 8.23 | 0.00 | C_ELEVATORCOREFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
278 | C_ELEVATORCOREFLR2_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 15.05 | 15.05 | 15.05 | 0.00 | 0.00 | 1.83 | 8.23 | 0.00 | F_ELEVATORCOREFLR3_10166_0_10095 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
279 | P_GUESTROOM219_10106_0_10066 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR2_6_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
280 | P_GUESTROOM219_10163_0_10094 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM215_218_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
281 | P_GUESTROOM219_10167_0_10096 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_ELEVATORCOREFLR2_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
282 | W_GUESTROOM219_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
283 | W_GUESTROOM219_3_0_0_0_0 | Window | W_GUESTROOM219_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
284 | F_GUESTROOM219_10073_0_10049 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_LAUNDRYROOMFLR1_1_1_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
285 | C_GUESTROOM219_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM319_10171_0_10097 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
286 | P_GUESTROOM220_223_10109_0_10069 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_CORRIDORFLR2_10_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
287 | P_GUESTROOM220_223_10110_0_10070 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_CORRIDORFLR2_11_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
288 | W_GUESTROOM220_223_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 36.90 | 43.48 | 36.90 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
289 | W_GUESTROOM220_223_3_0_0_0_0 | Window | W_GUESTROOM220_223_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
290 | W_GUESTROOM220_223_3_0_0_0_1 | Window | W_GUESTROOM220_223_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
291 | W_GUESTROOM220_223_3_0_0_0_2 | Window | W_GUESTROOM220_223_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
292 | W_GUESTROOM220_223_3_0_0_0_3 | Window | W_GUESTROOM220_223_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
293 | P_GUESTROOM220_223_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM224_10179_0_10099 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
294 | F_GUESTROOM220_223_10081_0_10052 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_EXERCISECENTERFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
295 | F_GUESTROOM220_223_10085_0_10054 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 97.83 | 97.83 | 97.83 | 180.00 | 180.00 | 11.89 | 8.23 | 0.00 | C_FRONTOFFICEFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
296 | C_GUESTROOM220_223_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 130.44 | 130.44 | 130.44 | 0.00 | 0.00 | 15.85 | 8.23 | 0.00 | F_GUESTROOM320_323_10177_0_10098 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
297 | P_GUESTROOM224_10111_0_10071 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR2_12_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
298 | P_GUESTROOM224_10179_0_10099 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM220_223_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
299 | W_GUESTROOM224_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
300 | W_GUESTROOM224_3_0_0_0_0 | Window | W_GUESTROOM224_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
301 | P_GUESTROOM224_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_FRONTSTORAGEFLR2_10184_0_10101 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
302 | F_GUESTROOM224_10086_0_10055 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_FRONTOFFICEFLR1_1_1_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
303 | C_GUESTROOM224_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM324_10182_0_10100 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
304 | P_FRONTSTORAGEFLR2_10112_0_10072 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 4.18 | 4.18 | 4.18 | 0.00 | 90.00 | 1.52 | 2.74 | 0.00 | P_CORRIDORFLR2_13_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
305 | P_FRONTSTORAGEFLR2_10184_0_10101 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM224_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
306 | W_FRONTSTORAGEFLR2_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 4.18 | 4.18 | 4.18 | 180.00 | 90.00 | 1.52 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
307 | P_FRONTSTORAGEFLR2_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_FRONTSTAIRSFLR2_10189_0_10103 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
308 | F_FRONTSTORAGEFLR2_10093_0_10059 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 12.54 | 12.54 | 12.54 | 180.00 | 180.00 | 1.52 | 8.23 | 0.00 | C_FRONTSTORAGEFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
309 | C_FRONTSTORAGEFLR2_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 12.54 | 12.54 | 12.54 | 0.00 | 0.00 | 1.52 | 8.23 | 0.00 | F_FRONTSTORAGEFLR3_10187_0_10102 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
310 | P_FRONTSTAIRSFLR2_10113_0_10073 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 0.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_CORRIDORFLR2_14_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
311 | P_FRONTSTAIRSFLR2_10189_0_10103 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_FRONTSTORAGEFLR2_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
312 | W_FRONTSTAIRSFLR2_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
313 | W_FRONTSTAIRSFLR2_4_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
314 | F_FRONTSTAIRSFLR2_10090_0_10057 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 20.07 | 20.07 | 20.07 | 180.00 | 180.00 | 2.44 | 8.23 | 0.00 | C_FRONTSTAIRSFLR1_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
315 | C_FRONTSTAIRSFLR2_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 20.07 | 20.07 | 20.07 | 0.00 | 0.00 | 2.44 | 8.23 | 0.00 | F_FRONTSTAIRSFLR3_10192_0_10104 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
316 | W_REARSTAIRSFLR3_2_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
317 | W_REARSTAIRSFLR3_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
318 | P_REARSTAIRSFLR3_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM314_10197_0_10106 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
319 | P_REARSTAIRSFLR3_5_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 0.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_CORRIDORFLR3_10198_0_10107 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
320 | F_REARSTAIRSFLR3_10098_0_10060 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 20.07 | 20.07 | 20.07 | 180.00 | 180.00 | 2.44 | 8.23 | 0.00 | C_REARSTAIRSFLR2_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
321 | C_REARSTAIRSFLR3_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 20.07 | 20.07 | 20.07 | 0.00 | 0.00 | 2.44 | 8.23 | 0.00 | F_REARSTAIRSFLR4_10196_0_10105 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
322 | P_CORRIDORFLR3_10198_0_10107 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_REARSTAIRSFLR3_5_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
323 | W_CORRIDORFLR3_2_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 3.71 | 5.02 | 3.71 | 270.00 | 90.00 | 1.83 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
324 | W_CORRIDORFLR3_2_0_0_0_0 | Window | W_CORRIDORFLR3_2_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.31 | 1.31 | 1.31 | 270.00 | 90.00 | 0.92 | 1.42 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
325 | P_CORRIDORFLR3_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM314_10202_0_10109 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
326 | P_CORRIDORFLR3_5_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_GUESTROOM315_318_10203_0_10110 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
327 | P_CORRIDORFLR3_6_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM319_10204_0_10111 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
328 | P_CORRIDORFLR3_7_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 5.02 | 5.02 | 5.02 | 180.00 | 90.00 | 1.83 | 2.74 | 0.00 | P_ELEVATORCOREFLR3_10205_0_10112 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
329 | P_CORRIDORFLR3_8_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_ELEVATORCOREFLR3_10206_0_10113 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
330 | W_CORRIDORFLR3_9_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 8.36 | 8.36 | 8.36 | 180.00 | 90.00 | 3.05 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
331 | P_CORRIDORFLR3_10_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM320_323_10207_0_10114 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
332 | P_CORRIDORFLR3_11_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_GUESTROOM320_323_10208_0_10115 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
333 | P_CORRIDORFLR3_12_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM324_10209_0_10116 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
334 | P_CORRIDORFLR3_13_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 4.18 | 4.18 | 4.18 | 180.00 | 90.00 | 1.52 | 2.74 | 0.00 | P_FRONTSTORAGEFLR3_10210_0_10117 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
335 | P_CORRIDORFLR3_14_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_FRONTSTAIRSFLR3_10211_0_10118 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
336 | W_CORRIDORFLR3_15_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 3.71 | 5.02 | 3.71 | 90.00 | 90.00 | 1.83 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
337 | W_CORRIDORFLR3_15_0_0_0_0 | Window | W_CORRIDORFLR3_15_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.31 | 1.31 | 1.31 | 90.00 | 90.00 | 0.92 | 1.42 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
338 | P_CORRIDORFLR3_16_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM301_10212_0_10119 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
339 | P_CORRIDORFLR3_17_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_GUESTROOM302_305_10213_0_10120 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
340 | P_CORRIDORFLR3_18_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.12 | 35.12 | 35.12 | 0.00 | 90.00 | 12.80 | 2.74 | 0.00 | P_GUESTROOM306_308_10214_0_10121 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
341 | P_CORRIDORFLR3_19_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_GUESTROOM309_312_10215_0_10122 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
342 | P_CORRIDORFLR3_20_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM313_10216_0_10123 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
343 | P_CORRIDORFLR3_21_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 0.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_REARSTORAGEFLR3_10217_0_10124 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
344 | F_CORRIDORFLR3_10102_0_10063 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 125.42 | 125.42 | 125.42 | 180.00 | 180.00 | 11.20 | 11.20 | 0.00 | C_CORRIDORFLR2_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 8 | ||
345 | C_CORRIDORFLR3_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 125.42 | 125.42 | 125.42 | 0.00 | 0.00 | 11.20 | 11.20 | 0.00 | F_CORRIDORFLR4_10200_0_10108 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
346 | P_REARSTORAGEFLR3_10217_0_10124 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_CORRIDORFLR3_21_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
347 | W_REARSTORAGEFLR3_2_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
348 | P_REARSTORAGEFLR3_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM313_10221_0_10126 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
349 | W_REARSTORAGEFLR3_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 6.69 | 6.69 | 6.69 | 0.00 | 90.00 | 2.44 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
350 | F_REARSTORAGEFLR3_10121_0_10080 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 20.07 | 20.07 | 20.07 | 180.00 | 180.00 | 2.44 | 8.23 | 0.00 | C_REARSTORAGEFLR2_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
351 | C_REARSTORAGEFLR3_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 20.07 | 20.07 | 20.07 | 0.00 | 0.00 | 2.44 | 8.23 | 0.00 | F_REARSTORAGEFLR4_10219_0_10125 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
352 | P_GUESTROOM301_10212_0_10119 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR3_16_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
353 | P_GUESTROOM301_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM302_305_10224_0_10128 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
354 | W_GUESTROOM301_4_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
355 | W_GUESTROOM301_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
356 | W_GUESTROOM301_5_0_0_0_0 | Window | W_GUESTROOM301_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
357 | F_GUESTROOM301_10125_0_10082 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM201_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
358 | C_GUESTROOM301_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM401_10223_0_10127 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
359 | P_GUESTROOM302_305_10213_0_10120 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_CORRIDORFLR3_17_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
360 | P_GUESTROOM302_305_10224_0_10128 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM301_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
361 | P_GUESTROOM302_305_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM306_308_10228_0_10130 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
362 | W_GUESTROOM302_305_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 36.90 | 43.48 | 36.90 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
363 | W_GUESTROOM302_305_5_0_0_0_0 | Window | W_GUESTROOM302_305_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
364 | W_GUESTROOM302_305_5_0_0_0_1 | Window | W_GUESTROOM302_305_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
365 | W_GUESTROOM302_305_5_0_0_0_2 | Window | W_GUESTROOM302_305_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
366 | W_GUESTROOM302_305_5_0_0_0_3 | Window | W_GUESTROOM302_305_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
367 | F_GUESTROOM302_305_10129_0_10084 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 130.45 | 130.45 | 130.45 | 180.00 | 180.00 | 15.85 | 8.23 | 0.00 | C_GUESTROOM202_205_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
368 | C_GUESTROOM302_305_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 130.45 | 130.45 | 130.45 | 0.00 | 0.00 | 15.85 | 8.23 | 0.00 | F_GUESTROOM402_405_10227_0_10129 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
369 | P_GUESTROOM306_308_10214_0_10121 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.12 | 35.12 | 35.12 | 180.00 | 90.00 | 12.80 | 2.74 | 0.00 | P_CORRIDORFLR3_18_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
370 | P_GUESTROOM306_308_10228_0_10130 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM302_305_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
371 | P_GUESTROOM306_308_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM309_312_10233_0_10132 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
372 | W_GUESTROOM306_308_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 28.42 | 35.12 | 28.42 | 0.00 | 90.00 | 12.80 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
373 | W_GUESTROOM306_308_5_0_0_0_0 | Window | W_GUESTROOM306_308_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
374 | W_GUESTROOM306_308_5_0_0_0_1 | Window | W_GUESTROOM306_308_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 3.41 | 3.41 | 3.41 | 0.00 | 90.00 | 2.36 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
375 | W_GUESTROOM306_308_5_0_0_0_2 | Window | W_GUESTROOM306_308_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
376 | F_GUESTROOM306_308_10136_0_10086 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 105.36 | 105.36 | 105.36 | 180.00 | 180.00 | 12.80 | 8.23 | 0.00 | C_GUESTROOM206_208_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
377 | C_GUESTROOM306_308_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 105.36 | 105.36 | 105.36 | 0.00 | 0.00 | 12.80 | 8.23 | 0.00 | F_GUESTROOM406_408_10232_0_10131 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
378 | P_GUESTROOM309_312_10215_0_10122 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_CORRIDORFLR3_19_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
379 | P_GUESTROOM309_312_10233_0_10132 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM306_308_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
380 | P_GUESTROOM309_312_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM313_10238_0_10134 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
381 | W_GUESTROOM309_312_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 36.90 | 43.48 | 36.90 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
382 | W_GUESTROOM309_312_5_0_0_0_0 | Window | W_GUESTROOM309_312_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
383 | W_GUESTROOM309_312_5_0_0_0_1 | Window | W_GUESTROOM309_312_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
384 | W_GUESTROOM309_312_5_0_0_0_2 | Window | W_GUESTROOM309_312_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
385 | W_GUESTROOM309_312_5_0_0_0_3 | Window | W_GUESTROOM309_312_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
386 | F_GUESTROOM309_312_10144_0_10088 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 130.45 | 130.45 | 130.45 | 180.00 | 180.00 | 15.85 | 8.23 | 0.00 | C_GUESTROOM209_212_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
387 | C_GUESTROOM309_312_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 130.45 | 130.45 | 130.45 | 0.00 | 0.00 | 15.85 | 8.23 | 0.00 | F_GUESTROOM409_412_10237_0_10133 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
388 | P_GUESTROOM313_10216_0_10123 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR3_20_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
389 | P_GUESTROOM313_10221_0_10126 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_REARSTORAGEFLR3_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
390 | P_GUESTROOM313_10238_0_10134 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM309_312_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
391 | W_GUESTROOM313_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
392 | W_GUESTROOM313_5_0_0_0_0 | Window | W_GUESTROOM313_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
393 | F_GUESTROOM313_10149_0_10090 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM213_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
394 | C_GUESTROOM313_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM413_10242_0_10135 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
395 | P_GUESTROOM314_10197_0_10106 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_REARSTAIRSFLR3_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
396 | P_GUESTROOM314_10202_0_10109 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR3_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
397 | W_GUESTROOM314_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
398 | W_GUESTROOM314_3_0_0_0_0 | Window | W_GUESTROOM314_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
399 | P_GUESTROOM314_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM315_318_10249_0_10137 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
400 | F_GUESTROOM314_10154_0_10091 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM214_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
401 | C_GUESTROOM314_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM414_10247_0_10136 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
402 | P_GUESTROOM315_318_10203_0_10110 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_CORRIDORFLR3_5_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
403 | P_GUESTROOM315_318_10249_0_10137 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM314_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
404 | W_GUESTROOM315_318_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 36.90 | 43.48 | 36.90 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
405 | W_GUESTROOM315_318_3_0_0_0_0 | Window | W_GUESTROOM315_318_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
406 | W_GUESTROOM315_318_3_0_0_0_1 | Window | W_GUESTROOM315_318_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
407 | W_GUESTROOM315_318_3_0_0_0_2 | Window | W_GUESTROOM315_318_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
408 | W_GUESTROOM315_318_3_0_0_0_3 | Window | W_GUESTROOM315_318_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
409 | P_GUESTROOM315_318_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM319_10254_0_10139 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
410 | F_GUESTROOM315_318_10161_0_10093 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 130.44 | 130.44 | 130.44 | 180.00 | 180.00 | 15.85 | 8.23 | 0.00 | C_GUESTROOM215_218_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
411 | C_GUESTROOM315_318_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 130.44 | 130.44 | 130.44 | 0.00 | 0.00 | 15.85 | 8.23 | 0.00 | F_GUESTROOM415_418_10252_0_10138 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
412 | P_ELEVATORCOREFLR3_10205_0_10112 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 5.02 | 5.02 | 5.02 | 0.00 | 90.00 | 1.83 | 2.74 | 0.00 | P_CORRIDORFLR3_7_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
413 | P_ELEVATORCOREFLR3_10206_0_10113 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_CORRIDORFLR3_8_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
414 | P_ELEVATORCOREFLR3_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM319_10258_0_10141 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
415 | W_ELEVATORCOREFLR3_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 5.02 | 5.02 | 5.02 | 180.00 | 90.00 | 1.83 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
416 | F_ELEVATORCOREFLR3_10166_0_10095 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 15.05 | 15.05 | 15.05 | 180.00 | 180.00 | 1.83 | 8.23 | 0.00 | C_ELEVATORCOREFLR2_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
417 | C_ELEVATORCOREFLR3_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 15.05 | 15.05 | 15.05 | 0.00 | 0.00 | 1.83 | 8.23 | 0.00 | F_ELEVATORCOREFLR4_10257_0_10140 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
418 | P_GUESTROOM319_10204_0_10111 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR3_6_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
419 | P_GUESTROOM319_10254_0_10139 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM315_318_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
420 | P_GUESTROOM319_10258_0_10141 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_ELEVATORCOREFLR3_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
421 | W_GUESTROOM319_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
422 | W_GUESTROOM319_3_0_0_0_0 | Window | W_GUESTROOM319_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
423 | F_GUESTROOM319_10171_0_10097 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM219_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
424 | C_GUESTROOM319_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM419_10262_0_10142 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
425 | P_GUESTROOM320_323_10207_0_10114 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_CORRIDORFLR3_10_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
426 | P_GUESTROOM320_323_10208_0_10115 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_CORRIDORFLR3_11_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
427 | W_GUESTROOM320_323_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 36.90 | 43.48 | 36.90 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
428 | W_GUESTROOM320_323_3_0_0_0_0 | Window | W_GUESTROOM320_323_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
429 | W_GUESTROOM320_323_3_0_0_0_1 | Window | W_GUESTROOM320_323_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
430 | W_GUESTROOM320_323_3_0_0_0_2 | Window | W_GUESTROOM320_323_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
431 | W_GUESTROOM320_323_3_0_0_0_3 | Window | W_GUESTROOM320_323_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
432 | P_GUESTROOM320_323_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM324_10269_0_10144 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
433 | F_GUESTROOM320_323_10177_0_10098 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 130.44 | 130.44 | 130.44 | 180.00 | 180.00 | 15.85 | 8.23 | 0.00 | C_GUESTROOM220_223_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
434 | C_GUESTROOM320_323_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 130.44 | 130.44 | 130.44 | 0.00 | 0.00 | 15.85 | 8.23 | 0.00 | F_GUESTROOM420_423_10267_0_10143 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
435 | P_GUESTROOM324_10209_0_10116 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR3_12_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
436 | P_GUESTROOM324_10269_0_10144 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM320_323_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
437 | W_GUESTROOM324_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
438 | W_GUESTROOM324_3_0_0_0_0 | Window | W_GUESTROOM324_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
439 | P_GUESTROOM324_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_FRONTSTORAGEFLR3_10274_0_10146 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
440 | F_GUESTROOM324_10182_0_10100 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM224_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
441 | C_GUESTROOM324_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | F_GUESTROOM424_10272_0_10145 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
442 | P_FRONTSTORAGEFLR3_10210_0_10117 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 4.18 | 4.18 | 4.18 | 0.00 | 90.00 | 1.52 | 2.74 | 0.00 | P_CORRIDORFLR3_13_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
443 | P_FRONTSTORAGEFLR3_10274_0_10146 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM324_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
444 | W_FRONTSTORAGEFLR3_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 4.18 | 4.18 | 4.18 | 180.00 | 90.00 | 1.52 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
445 | P_FRONTSTORAGEFLR3_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_FRONTSTAIRSFLR3_10279_0_10148 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
446 | F_FRONTSTORAGEFLR3_10187_0_10102 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 12.54 | 12.54 | 12.54 | 180.00 | 180.00 | 1.52 | 8.23 | 0.00 | C_FRONTSTORAGEFLR2_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
447 | C_FRONTSTORAGEFLR3_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 12.54 | 12.54 | 12.54 | 0.00 | 0.00 | 1.52 | 8.23 | 0.00 | F_FRONTSTORAGEFLR4_10277_0_10147 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
448 | P_FRONTSTAIRSFLR3_10211_0_10118 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 0.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_CORRIDORFLR3_14_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
449 | P_FRONTSTAIRSFLR3_10279_0_10148 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_FRONTSTORAGEFLR3_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
450 | W_FRONTSTAIRSFLR3_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
451 | W_FRONTSTAIRSFLR3_4_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
452 | F_FRONTSTAIRSFLR3_10192_0_10104 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 20.07 | 20.07 | 20.07 | 180.00 | 180.00 | 2.44 | 8.23 | 0.00 | C_FRONTSTAIRSFLR2_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
453 | C_FRONTSTAIRSFLR3_1_0_0 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 20.07 | 20.07 | 20.07 | 0.00 | 0.00 | 2.44 | 8.23 | 0.00 | F_FRONTSTAIRSFLR4_10282_0_10149 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
454 | W_REARSTAIRSFLR4_2_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
455 | W_REARSTAIRSFLR4_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
456 | P_REARSTAIRSFLR4_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM414_10286_0_10150 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
457 | P_REARSTAIRSFLR4_5_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 0.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_CORRIDORFLR4_10287_0_10151 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
458 | F_REARSTAIRSFLR4_10196_0_10105 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 20.07 | 20.07 | 20.07 | 180.00 | 180.00 | 2.44 | 8.23 | 0.00 | C_REARSTAIRSFLR3_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
459 | R_REARSTAIRSFLR4_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 20.07 | 20.07 | 20.07 | 0.00 | 0.00 | 2.44 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
460 | P_CORRIDORFLR4_10287_0_10151 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_REARSTAIRSFLR4_5_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
461 | W_CORRIDORFLR4_2_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 3.71 | 5.02 | 3.71 | 270.00 | 90.00 | 1.83 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
462 | W_CORRIDORFLR4_2_0_0_0_0 | Window | W_CORRIDORFLR4_2_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.31 | 1.31 | 1.31 | 270.00 | 90.00 | 0.92 | 1.42 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
463 | P_CORRIDORFLR4_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM414_10290_0_10152 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
464 | P_CORRIDORFLR4_5_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_GUESTROOM415_418_10291_0_10153 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
465 | P_CORRIDORFLR4_6_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM419_10292_0_10154 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
466 | P_CORRIDORFLR4_7_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 5.02 | 5.02 | 5.02 | 180.00 | 90.00 | 1.83 | 2.74 | 0.00 | P_ELEVATORCOREFLR4_10293_0_10155 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
467 | P_CORRIDORFLR4_8_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_ELEVATORCOREFLR4_10294_0_10156 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
468 | W_CORRIDORFLR4_9_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 8.36 | 8.36 | 8.36 | 180.00 | 90.00 | 3.05 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
469 | P_CORRIDORFLR4_10_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM420_423_10295_0_10157 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
470 | P_CORRIDORFLR4_11_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_GUESTROOM420_423_10296_0_10158 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
471 | P_CORRIDORFLR4_12_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM424_10297_0_10159 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
472 | P_CORRIDORFLR4_13_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 4.18 | 4.18 | 4.18 | 180.00 | 90.00 | 1.52 | 2.74 | 0.00 | P_FRONTSTORAGEFLR4_10298_0_10160 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
473 | P_CORRIDORFLR4_14_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_FRONTSTAIRSFLR4_10299_0_10161 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
474 | W_CORRIDORFLR4_15_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 3.71 | 5.02 | 3.71 | 90.00 | 90.00 | 1.83 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
475 | W_CORRIDORFLR4_15_0_0_0_0 | Window | W_CORRIDORFLR4_15_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.31 | 1.31 | 1.31 | 90.00 | 90.00 | 0.92 | 1.42 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
476 | P_CORRIDORFLR4_16_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM401_10300_0_10162 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
477 | P_CORRIDORFLR4_17_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_GUESTROOM402_405_10301_0_10163 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
478 | P_CORRIDORFLR4_18_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.12 | 35.12 | 35.12 | 0.00 | 90.00 | 12.80 | 2.74 | 0.00 | P_GUESTROOM406_408_10302_0_10164 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
479 | P_CORRIDORFLR4_19_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_GUESTROOM409_412_10303_0_10165 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
480 | P_CORRIDORFLR4_20_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_GUESTROOM413_10304_0_10166 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
481 | P_CORRIDORFLR4_21_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 0.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_REARSTORAGEFLR4_10305_0_10167 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
482 | F_CORRIDORFLR4_10200_0_10108 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 125.42 | 125.42 | 125.42 | 180.00 | 180.00 | 11.20 | 11.20 | 0.00 | C_CORRIDORFLR3_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 8 | ||
483 | R_CORRIDORFLR4_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 125.42 | 125.42 | 125.42 | 0.00 | 0.00 | 11.20 | 11.20 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
484 | P_REARSTORAGEFLR4_10305_0_10167 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_CORRIDORFLR4_21_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
485 | W_REARSTORAGEFLR4_2_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
486 | P_REARSTORAGEFLR4_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM413_10308_0_10168 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
487 | W_REARSTORAGEFLR4_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 6.69 | 6.69 | 6.69 | 0.00 | 90.00 | 2.44 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
488 | F_REARSTORAGEFLR4_10219_0_10125 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 20.07 | 20.07 | 20.07 | 180.00 | 180.00 | 2.44 | 8.23 | 0.00 | C_REARSTORAGEFLR3_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
489 | R_REARSTORAGEFLR4_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 20.07 | 20.07 | 20.07 | 0.00 | 0.00 | 2.44 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
490 | P_GUESTROOM401_10300_0_10162 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR4_16_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
491 | P_GUESTROOM401_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM402_405_10310_0_10169 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
492 | W_GUESTROOM401_4_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
493 | W_GUESTROOM401_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
494 | W_GUESTROOM401_5_0_0_0_0 | Window | W_GUESTROOM401_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
495 | F_GUESTROOM401_10223_0_10127 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM301_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
496 | R_GUESTROOM401_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
497 | P_GUESTROOM402_405_10301_0_10163 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_CORRIDORFLR4_17_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
498 | P_GUESTROOM402_405_10310_0_10169 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM401_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
499 | P_GUESTROOM402_405_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM406_408_10313_0_10170 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
500 | W_GUESTROOM402_405_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 36.90 | 43.48 | 36.90 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
501 | W_GUESTROOM402_405_5_0_0_0_0 | Window | W_GUESTROOM402_405_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
502 | W_GUESTROOM402_405_5_0_0_0_1 | Window | W_GUESTROOM402_405_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
503 | W_GUESTROOM402_405_5_0_0_0_2 | Window | W_GUESTROOM402_405_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
504 | W_GUESTROOM402_405_5_0_0_0_3 | Window | W_GUESTROOM402_405_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
505 | F_GUESTROOM402_405_10227_0_10129 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 130.45 | 130.45 | 130.45 | 180.00 | 180.00 | 15.85 | 8.23 | 0.00 | C_GUESTROOM302_305_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
506 | R_GUESTROOM402_405_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 130.45 | 130.45 | 130.45 | 0.00 | 0.00 | 15.85 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
507 | P_GUESTROOM406_408_10302_0_10164 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.12 | 35.12 | 35.12 | 180.00 | 90.00 | 12.80 | 2.74 | 0.00 | P_CORRIDORFLR4_18_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
508 | P_GUESTROOM406_408_10313_0_10170 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM402_405_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
509 | P_GUESTROOM406_408_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM409_412_10317_0_10171 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
510 | W_GUESTROOM406_408_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 28.42 | 35.12 | 28.42 | 0.00 | 90.00 | 12.80 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
511 | W_GUESTROOM406_408_5_0_0_0_0 | Window | W_GUESTROOM406_408_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
512 | W_GUESTROOM406_408_5_0_0_0_1 | Window | W_GUESTROOM406_408_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
513 | W_GUESTROOM406_408_5_0_0_0_2 | Window | W_GUESTROOM406_408_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 3.41 | 3.41 | 3.41 | 0.00 | 90.00 | 2.36 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
514 | F_GUESTROOM406_408_10232_0_10131 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 105.36 | 105.36 | 105.36 | 180.00 | 180.00 | 12.80 | 8.23 | 0.00 | C_GUESTROOM306_308_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
515 | R_GUESTROOM406_408_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 105.36 | 105.36 | 105.36 | 0.00 | 0.00 | 12.80 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
516 | P_GUESTROOM409_412_10303_0_10165 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_CORRIDORFLR4_19_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
517 | P_GUESTROOM409_412_10317_0_10171 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM406_408_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
518 | P_GUESTROOM409_412_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM413_10321_0_10172 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
519 | W_GUESTROOM409_412_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 36.90 | 43.48 | 36.90 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
520 | W_GUESTROOM409_412_5_0_0_0_0 | Window | W_GUESTROOM409_412_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
521 | W_GUESTROOM409_412_5_0_0_0_1 | Window | W_GUESTROOM409_412_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
522 | W_GUESTROOM409_412_5_0_0_0_2 | Window | W_GUESTROOM409_412_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
523 | W_GUESTROOM409_412_5_0_0_0_3 | Window | W_GUESTROOM409_412_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
524 | F_GUESTROOM409_412_10237_0_10133 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 130.45 | 130.45 | 130.45 | 180.00 | 180.00 | 15.85 | 8.23 | 0.00 | C_GUESTROOM309_312_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
525 | R_GUESTROOM409_412_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 130.45 | 130.45 | 130.45 | 0.00 | 0.00 | 15.85 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
526 | P_GUESTROOM413_10304_0_10166 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR4_20_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
527 | P_GUESTROOM413_10308_0_10168 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_REARSTORAGEFLR4_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
528 | P_GUESTROOM413_10321_0_10172 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM409_412_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
529 | W_GUESTROOM413_5_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
530 | W_GUESTROOM413_5_0_0_0_0 | Window | W_GUESTROOM413_5_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 0.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
531 | F_GUESTROOM413_10242_0_10135 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM313_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
532 | R_GUESTROOM413_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
533 | P_GUESTROOM414_10286_0_10150 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_REARSTAIRSFLR4_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
534 | P_GUESTROOM414_10290_0_10152 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR4_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
535 | W_GUESTROOM414_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
536 | W_GUESTROOM414_3_0_0_0_0 | Window | W_GUESTROOM414_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
537 | P_GUESTROOM414_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM415_418_10330_0_10173 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
538 | F_GUESTROOM414_10247_0_10136 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM314_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
539 | R_GUESTROOM414_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
540 | P_GUESTROOM415_418_10291_0_10153 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_CORRIDORFLR4_5_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
541 | P_GUESTROOM415_418_10330_0_10173 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM414_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
542 | W_GUESTROOM415_418_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 36.90 | 43.48 | 36.90 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
543 | W_GUESTROOM415_418_3_0_0_0_0 | Window | W_GUESTROOM415_418_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
544 | W_GUESTROOM415_418_3_0_0_0_1 | Window | W_GUESTROOM415_418_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
545 | W_GUESTROOM415_418_3_0_0_0_2 | Window | W_GUESTROOM415_418_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
546 | W_GUESTROOM415_418_3_0_0_0_3 | Window | W_GUESTROOM415_418_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
547 | P_GUESTROOM415_418_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM419_10334_0_10174 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
548 | F_GUESTROOM415_418_10252_0_10138 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 130.44 | 130.44 | 130.44 | 180.00 | 180.00 | 15.85 | 8.23 | 0.00 | C_GUESTROOM315_318_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
549 | R_GUESTROOM415_418_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 130.44 | 130.44 | 130.44 | 0.00 | 0.00 | 15.85 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
550 | P_ELEVATORCOREFLR4_10293_0_10155 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 5.02 | 5.02 | 5.02 | 0.00 | 90.00 | 1.83 | 2.74 | 0.00 | P_CORRIDORFLR4_7_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
551 | P_ELEVATORCOREFLR4_10294_0_10156 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_CORRIDORFLR4_8_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
552 | P_ELEVATORCOREFLR4_2_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM419_10337_0_10175 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
553 | W_ELEVATORCOREFLR4_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 5.02 | 5.02 | 5.02 | 180.00 | 90.00 | 1.83 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
554 | F_ELEVATORCOREFLR4_10257_0_10140 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 15.05 | 15.05 | 15.05 | 180.00 | 180.00 | 1.83 | 8.23 | 0.00 | C_ELEVATORCOREFLR3_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
555 | R_ELEVATORCOREFLR4_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 15.05 | 15.05 | 15.05 | 0.00 | 0.00 | 1.83 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
556 | P_GUESTROOM419_10292_0_10154 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR4_6_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
557 | P_GUESTROOM419_10334_0_10174 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM415_418_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
558 | P_GUESTROOM419_10337_0_10175 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_ELEVATORCOREFLR4_2_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
559 | W_GUESTROOM419_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
560 | W_GUESTROOM419_3_0_0_0_0 | Window | W_GUESTROOM419_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
561 | F_GUESTROOM419_10262_0_10142 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM319_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
562 | R_GUESTROOM419_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
563 | P_GUESTROOM420_423_10295_0_10157 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_CORRIDORFLR4_10_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
564 | P_GUESTROOM420_423_10296_0_10158 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 43.48 | 43.48 | 43.48 | 0.00 | 90.00 | 15.85 | 2.74 | 0.00 | P_CORRIDORFLR4_11_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
565 | W_GUESTROOM420_423_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 36.90 | 43.48 | 36.90 | 180.00 | 90.00 | 15.85 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
566 | W_GUESTROOM420_423_3_0_0_0_0 | Window | W_GUESTROOM420_423_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
567 | W_GUESTROOM420_423_3_0_0_0_1 | Window | W_GUESTROOM420_423_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
568 | W_GUESTROOM420_423_3_0_0_0_2 | Window | W_GUESTROOM420_423_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
569 | W_GUESTROOM420_423_3_0_0_0_3 | Window | W_GUESTROOM420_423_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
570 | P_GUESTROOM420_423_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM424_10346_0_10176 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
571 | F_GUESTROOM420_423_10267_0_10143 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 130.44 | 130.44 | 130.44 | 180.00 | 180.00 | 15.85 | 8.23 | 0.00 | C_GUESTROOM320_323_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
572 | R_GUESTROOM420_423_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 130.44 | 130.44 | 130.44 | 0.00 | 0.00 | 15.85 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
573 | P_GUESTROOM424_10297_0_10159 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 10.87 | 10.87 | 10.87 | 0.00 | 90.00 | 3.96 | 2.74 | 0.00 | P_CORRIDORFLR4_12_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
574 | P_GUESTROOM424_10346_0_10176 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM420_423_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
575 | W_GUESTROOM424_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 9.22 | 10.87 | 9.22 | 180.00 | 90.00 | 3.96 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
576 | W_GUESTROOM424_3_0_0_0_0 | Window | W_GUESTROOM424_3_0_0 | Window5 Detailed Fenestration | RESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 1.65 | 1.65 | 1.65 | 180.00 | 90.00 | 1.14 | 1.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
577 | P_GUESTROOM424_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_FRONTSTORAGEFLR4_10350_0_10177 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
578 | F_GUESTROOM424_10272_0_10145 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 32.61 | 32.61 | 32.61 | 180.00 | 180.00 | 3.96 | 8.23 | 0.00 | C_GUESTROOM324_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
579 | R_GUESTROOM424_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 32.61 | 32.61 | 32.61 | 0.00 | 0.00 | 3.96 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
580 | P_FRONTSTORAGEFLR4_10298_0_10160 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 4.18 | 4.18 | 4.18 | 0.00 | 90.00 | 1.52 | 2.74 | 0.00 | P_CORRIDORFLR4_13_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
581 | P_FRONTSTORAGEFLR4_10350_0_10177 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_GUESTROOM424_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
582 | W_FRONTSTORAGEFLR4_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 4.18 | 4.18 | 4.18 | 180.00 | 90.00 | 1.52 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
583 | P_FRONTSTORAGEFLR4_4_0_0 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_FRONTSTAIRSFLR4_10354_0_10178 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
584 | F_FRONTSTORAGEFLR4_10277_0_10147 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 12.54 | 12.54 | 12.54 | 180.00 | 180.00 | 1.52 | 8.23 | 0.00 | C_FRONTSTORAGEFLR3_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
585 | R_FRONTSTORAGEFLR4_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 12.54 | 12.54 | 12.54 | 0.00 | 0.00 | 1.52 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
586 | P_FRONTSTAIRSFLR4_10299_0_10161 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 6.69 | 6.69 | 6.69 | 0.00 | 90.00 | 2.44 | 2.74 | 0.00 | P_CORRIDORFLR4_14_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
587 | P_FRONTSTAIRSFLR4_10354_0_10178 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.58 | 22.58 | 22.58 | 270.00 | 90.00 | 8.23 | 2.74 | 0.00 | P_FRONTSTORAGEFLR4_4_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
588 | W_FRONTSTAIRSFLR4_3_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 6.69 | 6.69 | 6.69 | 180.00 | 90.00 | 2.44 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
589 | W_FRONTSTAIRSFLR4_4_0_0 | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL | 0.384 | 0.363 | 22.58 | 22.58 | 22.58 | 90.00 | 90.00 | 8.23 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
590 | F_FRONTSTAIRSFLR4_10282_0_10149 | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 20.07 | 20.07 | 20.07 | 180.00 | 180.00 | 2.44 | 8.23 | 0.00 | C_FRONTSTAIRSFLR3_1_0_0 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
591 | R_FRONTSTAIRSFLR4_1_0_0 | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 20.07 | 20.07 | 20.07 | 0.00 | 0.00 | 2.44 | 8.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Transmittance Schedule | Min Schedule Value | Max Schedule Value | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | ENTRY CANOPY | Shading | W_CORRIDORFLR1_2_0_0 | None | 0.0 | 0.0 | 83.60 | 83.60 | 83.60 | 270.00 | 0.00 | 9.14 | 9.14 | 4 | ||||||||||||
2 | Mir-ENTRY CANOPY | Shading | W_CORRIDORFLR1_2_0_0 | None | 0.0 | 0.0 | 83.60 | 83.60 | 83.60 | 90.00 | 180.00 | 9.14 | 9.14 | 4 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | Yes | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/02 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/13 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 7 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | REARSTAIRSFLR1 | RunPeriod: RUNPERIOD 1 | 5.0674996784E-002 | 3.9375352172E-002 | Pass | Pass | 0.4297089954 | 1.3750911204 | Pass | Pass |
2 | CORRIDORFLR1 | RunPeriod: RUNPERIOD 1 | 0.1320530364 | 0.3644062557 | Pass | Pass | 0.1740592694 | 1.1660601705 | Pass | Pass |
3 | REARSTORAGEFLR1 | RunPeriod: RUNPERIOD 1 | 4.2872421673E-002 | 3.2741265254E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
4 | FRONTLOUNGEFLR1 | RunPeriod: RUNPERIOD 1 | 4.4113056100E-002 | 0.1199682043 | Pass | Pass | 2.5430582088E-002 | 6.3059992484E-002 | Pass | Pass |
5 | RESTROOMFLR1 | RunPeriod: RUNPERIOD 1 | 4.2006505727E-002 | 6.4657173754E-002 | Pass | Pass | 5.6038521629E-002 | 0.1830740532 | Pass | Pass |
6 | MEETINGROOMFLR1 | RunPeriod: RUNPERIOD 1 | 4.9472519135E-002 | 0.1267861999 | Pass | Pass | 8.3000853828E-002 | 0.1829741767 | Pass | Pass |
7 | MECHANICALROOMFLR1 | RunPeriod: RUNPERIOD 1 | 1.3935778405E-002 | 9.9272080863E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
8 | GUESTROOM101 | RunPeriod: RUNPERIOD 1 | 1.2576376456E-002 | 1.3165561602E-002 | Pass | Pass | 7.6505779885E-003 | 8.3255314395E-002 | Pass | Pass |
9 | GUESTROOM102 | RunPeriod: RUNPERIOD 1 | 1.2612787921E-002 | 1.1185397544E-002 | Pass | Pass | 7.8379147848E-003 | 8.4319597820E-002 | Pass | Pass |
10 | GUESTROOM103 | RunPeriod: RUNPERIOD 1 | 6.7878573557E-002 | 0.2285026797 | Pass | Pass | 5.2009321332E-002 | 0.1729210009 | Pass | Pass |
11 | GUESTROOM104 | RunPeriod: RUNPERIOD 1 | 9.2706615315E-002 | 0.3240751920 | Pass | Pass | 9.0444147052E-002 | 0.3506741232 | Pass | Pass |
12 | GUESTROOM105 | RunPeriod: RUNPERIOD 1 | 9.2749757925E-002 | 0.3524595582 | Pass | Pass | 8.2131266321E-002 | 0.3225277630 | Pass | Pass |
13 | EMPLOYEELOUNGEFLR1 | RunPeriod: RUNPERIOD 1 | 0.1321797258 | 0.3086150632 | Pass | Pass | 2.4810477454E-002 | 5.1866499396E-002 | Pass | Pass |
14 | LAUNDRYROOMFLR1 | RunPeriod: RUNPERIOD 1 | 0.6534041439 | 2.3991512473 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
15 | ELEVATORCOREFLR1 | RunPeriod: RUNPERIOD 1 | 0.9254141482 | 1.7227147154 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
16 | EXERCISECENTERFLR1 | RunPeriod: RUNPERIOD 1 | 1.1259722413E-002 | 4.9759070586E-002 | Pass | Pass | 4.5228514783E-002 | 0.1417818683 | Pass | Pass |
17 | FRONTOFFICEFLR1 | RunPeriod: RUNPERIOD 1 | 2.6840341547E-002 | 8.5781567041E-002 | Pass | Pass | 3.9233447070E-002 | 7.9034573359E-002 | Pass | Pass |
18 | FRONTSTAIRSFLR1 | RunPeriod: RUNPERIOD 1 | 4.4197572625E-002 | 3.2861454825E-002 | Pass | Pass | 0.2943096341 | 0.8451131187 | Pass | Pass |
19 | FRONTSTORAGEFLR1 | RunPeriod: RUNPERIOD 1 | 2.1695573943E-002 | 1.4382233628E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
20 | REARSTAIRSFLR2 | RunPeriod: RUNPERIOD 1 | 4.9109144717E-002 | 3.7072673418E-002 | Pass | Pass | 0.3782976130 | 1.0660373628 | Pass | Pass |
21 | CORRIDORFLR2 | RunPeriod: RUNPERIOD 1 | 1.8191516005E-002 | 1.9446720845E-002 | Pass | Pass | 1.9271952023E-002 | 1.6310925853E-002 | Pass | Pass |
22 | REARSTORAGEFLR2 | RunPeriod: RUNPERIOD 1 | 4.1814635324E-002 | 3.0586191125E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
23 | GUESTROOM201 | RunPeriod: RUNPERIOD 1 | 1.8388830182E-002 | 1.5749495376E-002 | Pass | Pass | 8.0659623561E-003 | 8.4522768611E-002 | Pass | Pass |
24 | GUESTROOM202_205 | RunPeriod: RUNPERIOD 1 | 8.0702435739E-002 | 0.2704100838 | Pass | Pass | 6.4061610229E-002 | 0.1948882816 | Pass | Pass |
25 | GUESTROOM206_208 | RunPeriod: RUNPERIOD 1 | 8.9539942771E-002 | 0.2961170126 | Pass | Pass | 7.2144600987E-002 | 0.2220122047 | Pass | Pass |
26 | GUESTROOM209_212 | RunPeriod: RUNPERIOD 1 | 9.3206364757E-002 | 0.3093107515 | Pass | Pass | 6.1102202229E-002 | 0.1651594745 | Pass | Pass |
27 | GUESTROOM213 | RunPeriod: RUNPERIOD 1 | 4.8998237551E-002 | 0.1779326195 | Pass | Pass | 7.6153550709E-002 | 0.2539665235 | Pass | Pass |
28 | GUESTROOM214 | RunPeriod: RUNPERIOD 1 | 9.2705008791E-002 | 0.3388509926 | Pass | Pass | 9.3386370860E-002 | 0.3245445472 | Pass | Pass |
29 | GUESTROOM215_218 | RunPeriod: RUNPERIOD 1 | 3.1469730246E-006 | 3.4768443495E-006 | Pass | Pass | 1.7799345984E-002 | 8.8918944217E-003 | Pass | Pass |
30 | ELEVATORCOREFLR2 | RunPeriod: RUNPERIOD 1 | 5.0764872898E-002 | 3.3331073520E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
31 | GUESTROOM219 | RunPeriod: RUNPERIOD 1 | 8.5191522982E-002 | 0.2272651304 | Pass | Pass | 9.3071984035E-003 | 3.7923409744E-002 | Pass | Pass |
32 | GUESTROOM220_223 | RunPeriod: RUNPERIOD 1 | 9.2702619985E-002 | 0.3383853542 | Pass | Pass | 9.7306151165E-002 | 0.3422277120 | Pass | Pass |
33 | GUESTROOM224 | RunPeriod: RUNPERIOD 1 | 9.2684987199E-002 | 0.3336630390 | Pass | Pass | 8.6357097503E-002 | 0.3201311365 | Pass | Pass |
34 | FRONTSTORAGEFLR2 | RunPeriod: RUNPERIOD 1 | 1.9630368687E-002 | 1.6231257188E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
35 | FRONTSTAIRSFLR2 | RunPeriod: RUNPERIOD 1 | 4.1349561049E-002 | 3.2235825060E-002 | Pass | Pass | 0.1862670307 | 0.2460659999 | Pass | Pass |
36 | REARSTAIRSFLR3 | RunPeriod: RUNPERIOD 1 | 5.0380597101E-002 | 3.7488940167E-002 | Pass | Pass | 1.0073295923 | 7.5199856666 | Pass | Pass |
37 | CORRIDORFLR3 | RunPeriod: RUNPERIOD 1 | 1.7309162932E-002 | 1.6779062929E-002 | Pass | Pass | 2.0678424500E-002 | 1.4994774383E-002 | Pass | Pass |
38 | REARSTORAGEFLR3 | RunPeriod: RUNPERIOD 1 | 4.3301194178E-002 | 3.0851401760E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
39 | GUESTROOM301 | RunPeriod: RUNPERIOD 1 | 1.9491099047E-002 | 1.5184192715E-002 | Pass | Pass | 9.3916958489E-003 | 7.9825905589E-002 | Pass | Pass |
40 | GUESTROOM302_305 | RunPeriod: RUNPERIOD 1 | 1.1701437161E-002 | 8.3835157342E-003 | Pass | Pass | 1.1389359977E-002 | 8.3648057568E-002 | Pass | Pass |
41 | GUESTROOM306_308 | RunPeriod: RUNPERIOD 1 | 1.2114074317E-002 | 8.5285076865E-003 | Pass | Pass | 1.0006236506E-002 | 9.2471801049E-002 | Pass | Pass |
42 | GUESTROOM309_312 | RunPeriod: RUNPERIOD 1 | 7.7676540248E-002 | 0.2608086762 | Pass | Pass | 6.2687297305E-002 | 0.1997960659 | Pass | Pass |
43 | GUESTROOM313 | RunPeriod: RUNPERIOD 1 | 1.1937611333E-002 | 7.6007919677E-003 | Pass | Pass | 9.1349472044E-003 | 8.0206653745E-002 | Pass | Pass |
44 | GUESTROOM314 | RunPeriod: RUNPERIOD 1 | 9.2840979567E-002 | 0.3128052343 | Pass | Pass | 9.8093745661E-002 | 0.3301351393 | Pass | Pass |
45 | GUESTROOM315_318 | RunPeriod: RUNPERIOD 1 | 9.2726694332E-002 | 0.3473152044 | Pass | Pass | 0.1375046032 | 0.8967651617 | Pass | Pass |
46 | ELEVATORCOREFLR3 | RunPeriod: RUNPERIOD 1 | 1.7245465346E-002 | 1.3714666352E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
47 | GUESTROOM319 | RunPeriod: RUNPERIOD 1 | 2.8746496821E-002 | 2.5338041944E-002 | Pass | Pass | 7.6787314687E-003 | 8.1222870411E-002 | Pass | Pass |
48 | GUESTROOM320_323 | RunPeriod: RUNPERIOD 1 | 9.2671094209E-002 | 0.3273465308 | Pass | Pass | 9.3778075680E-002 | 0.2846005437 | Pass | Pass |
49 | GUESTROOM324 | RunPeriod: RUNPERIOD 1 | 3.0174777192E-002 | 1.9940479764E-002 | Pass | Pass | 7.7310408051E-003 | 8.1765255749E-002 | Pass | Pass |
50 | FRONTSTORAGEFLR3 | RunPeriod: RUNPERIOD 1 | 2.1607269461E-002 | 1.5467936879E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
51 | FRONTSTAIRSFLR3 | RunPeriod: RUNPERIOD 1 | 4.2464128792E-002 | 3.2704850623E-002 | Pass | Pass | 0.1970735006 | 0.2731064344 | Pass | Pass |
52 | REARSTAIRSFLR4 | RunPeriod: RUNPERIOD 1 | 8.5812307899E-002 | 6.0726868791E-002 | Pass | Pass | 0.6206879173 | 2.8111214155 | Pass | Pass |
53 | CORRIDORFLR4 | RunPeriod: RUNPERIOD 1 | 1.7102693621E-002 | 2.8954128172E-002 | Pass | Pass | 0.1492831825 | 0.5078520716 | Pass | Pass |
54 | REARSTORAGEFLR4 | RunPeriod: RUNPERIOD 1 | 6.9936420762E-002 | 5.0272671158E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
55 | GUESTROOM401 | RunPeriod: RUNPERIOD 1 | 2.6802223435E-002 | 7.5324545580E-002 | Pass | Pass | 0.2708588589 | 2.1694140905 | Pass | Pass |
56 | GUESTROOM402_405 | RunPeriod: RUNPERIOD 1 | 4.0284163606E-002 | 2.8398257495E-002 | Pass | Pass | 1.0679325629 | 12.3942897384 | Pass | Pass |
57 | GUESTROOM406_408 | RunPeriod: RUNPERIOD 1 | 4.0948479901E-002 | 2.8790890240E-002 | Pass | Pass | 1.3983902253E-002 | 0.1166586904 | Pass | Pass |
58 | GUESTROOM409_412 | RunPeriod: RUNPERIOD 1 | 6.7177447339E-002 | 0.2245151641 | Pass | Pass | 0.2865376501 | 1.2514736773 | Pass | Pass |
59 | GUESTROOM413 | RunPeriod: RUNPERIOD 1 | 3.7021575973E-002 | 2.0762502445E-002 | Pass | Pass | 2.0054368283E-002 | 0.1403042785 | Pass | Pass |
60 | GUESTROOM414 | RunPeriod: RUNPERIOD 1 | 6.8485285025E-002 | 4.4098052620E-002 | Pass | Pass | 8.3093707836E-003 | 8.5480262016E-002 | Pass | Pass |
61 | GUESTROOM415_418 | RunPeriod: RUNPERIOD 1 | 9.2662257704E-002 | 0.3237343689 | Pass | Pass | 0.1107912437 | 0.3191626394 | Pass | Pass |
62 | ELEVATORCOREFLR4 | RunPeriod: RUNPERIOD 1 | 4.2565958109E-002 | 2.9484130313E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
63 | GUESTROOM419 | RunPeriod: RUNPERIOD 1 | 9.2679988340E-002 | 0.3248761687 | Pass | Pass | 0.1047971078 | 0.3706955834 | Pass | Pass |
64 | GUESTROOM420_423 | RunPeriod: RUNPERIOD 1 | 9.2649820685E-002 | 0.3182615810 | Pass | Pass | 0.1542795841 | 0.3859169448 | Pass | Pass |
65 | GUESTROOM424 | RunPeriod: RUNPERIOD 1 | 8.2445336658E-002 | 0.2799731340 | Pass | Pass | 0.1708796998 | 0.3591532917 | Pass | Pass |
66 | FRONTSTORAGEFLR4 | RunPeriod: RUNPERIOD 1 | 5.0943923190E-002 | 3.1844466465E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
67 | FRONTSTAIRSFLR4 | RunPeriod: RUNPERIOD 1 | 6.9560208852E-002 | 5.1506936939E-002 | Pass | Pass | 0.6388331233 | 3.1648099871 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 20:15:15
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 0.50 | 0.00 | 0.50 | Wetbulb [C] | 2.10 | 140.00 |
TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 40.80 | 13.30 | 18.50 | Wetbulb [C] | 4.80 | 310.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 20:15:15
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
W_REARSTAIRSFLR1_2_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 27.59 | 27.59 | 270.00 | 90.00 | W |
W_REARSTAIRSFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 8.18 | 6.23 | 180.00 | 90.00 | S |
W_CORRIDORFLR1_2_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 6.13 | 3.44 | 270.00 | 90.00 | W |
W_CORRIDORFLR1_10_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 10.22 | 8.27 | 180.00 | 90.00 | S |
W_CORRIDORFLR1_16_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 6.13 | 1.69 | 90.00 | 90.00 | E |
W_CORRIDORFLR1_20_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 10.22 | 7.53 | 0.00 | 90.00 | N |
W_REARSTORAGEFLR1_2_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 27.59 | 27.59 | 270.00 | 90.00 | W |
W_REARSTORAGEFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 8.18 | 8.18 | 0.00 | 90.00 | N |
W_FRONTLOUNGEFLR1_4_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 27.59 | 27.59 | 90.00 | 90.00 | E |
W_FRONTLOUNGEFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 66.43 | 51.60 | 0.00 | 90.00 | N |
W_RESTROOMFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 13.29 | 13.29 | 0.00 | 90.00 | N |
W_MEETINGROOMFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 32.70 | 27.77 | 0.00 | 90.00 | N |
W_MECHANICALROOMFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 13.29 | 13.29 | 0.00 | 90.00 | N |
W_GUESTROOM101_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 13.29 | 11.64 | 0.00 | 90.00 | N |
W_GUESTROOM102_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 13.29 | 11.64 | 0.00 | 90.00 | N |
W_GUESTROOM103_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 13.29 | 11.64 | 0.00 | 90.00 | N |
W_GUESTROOM104_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 13.29 | 11.64 | 180.00 | 90.00 | S |
W_GUESTROOM105_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 13.29 | 11.64 | 180.00 | 90.00 | S |
W_EMPLOYEELOUNGEFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 13.29 | 11.64 | 180.00 | 90.00 | S |
W_LAUNDRYROOMFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.86 | 34.92 | 180.00 | 90.00 | S |
W_ELEVATORCOREFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 6.13 | 6.13 | 180.00 | 90.00 | S |
W_EXERCISECENTERFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 13.29 | 11.64 | 180.00 | 90.00 | S |
W_FRONTOFFICEFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 53.14 | 46.56 | 180.00 | 90.00 | S |
W_FRONTSTAIRSFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 8.18 | 6.22 | 180.00 | 90.00 | S |
W_FRONTSTAIRSFLR1_4_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 27.59 | 27.59 | 90.00 | 90.00 | E |
W_FRONTSTORAGEFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 5.11 | 5.11 | 180.00 | 90.00 | S |
W_REARSTAIRSFLR2_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 22.58 | 270.00 | 90.00 | W |
W_REARSTAIRSFLR2_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 6.69 | 180.00 | 90.00 | S |
W_CORRIDORFLR2_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 3.71 | 270.00 | 90.00 | W |
W_CORRIDORFLR2_9_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.36 | 8.36 | 180.00 | 90.00 | S |
W_CORRIDORFLR2_15_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 3.71 | 90.00 | 90.00 | E |
W_REARSTORAGEFLR2_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 22.58 | 270.00 | 90.00 | W |
W_REARSTORAGEFLR2_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 6.69 | 0.00 | 90.00 | N |
W_GUESTROOM201_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 22.58 | 90.00 | 90.00 | E |
W_GUESTROOM201_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 0.00 | 90.00 | N |
W_GUESTROOM202_205_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 36.90 | 0.00 | 90.00 | N |
W_GUESTROOM206_208_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.12 | 28.42 | 0.00 | 90.00 | N |
W_GUESTROOM209_212_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 36.90 | 0.00 | 90.00 | N |
W_GUESTROOM213_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 0.00 | 90.00 | N |
W_GUESTROOM214_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 180.00 | 90.00 | S |
W_GUESTROOM215_218_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 36.90 | 180.00 | 90.00 | S |
W_ELEVATORCOREFLR2_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 5.02 | 180.00 | 90.00 | S |
W_GUESTROOM219_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 180.00 | 90.00 | S |
W_GUESTROOM220_223_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 36.90 | 180.00 | 90.00 | S |
W_GUESTROOM224_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 180.00 | 90.00 | S |
W_FRONTSTORAGEFLR2_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 4.18 | 4.18 | 180.00 | 90.00 | S |
W_FRONTSTAIRSFLR2_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 6.69 | 180.00 | 90.00 | S |
W_FRONTSTAIRSFLR2_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 22.58 | 90.00 | 90.00 | E |
W_REARSTAIRSFLR3_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 22.58 | 270.00 | 90.00 | W |
W_REARSTAIRSFLR3_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 6.69 | 180.00 | 90.00 | S |
W_CORRIDORFLR3_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 3.71 | 270.00 | 90.00 | W |
W_CORRIDORFLR3_9_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.36 | 8.36 | 180.00 | 90.00 | S |
W_CORRIDORFLR3_15_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 3.71 | 90.00 | 90.00 | E |
W_REARSTORAGEFLR3_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 22.58 | 270.00 | 90.00 | W |
W_REARSTORAGEFLR3_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 6.69 | 0.00 | 90.00 | N |
W_GUESTROOM301_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 22.58 | 90.00 | 90.00 | E |
W_GUESTROOM301_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 0.00 | 90.00 | N |
W_GUESTROOM302_305_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 36.90 | 0.00 | 90.00 | N |
W_GUESTROOM306_308_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.12 | 28.42 | 0.00 | 90.00 | N |
W_GUESTROOM309_312_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 36.90 | 0.00 | 90.00 | N |
W_GUESTROOM313_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 0.00 | 90.00 | N |
W_GUESTROOM314_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 180.00 | 90.00 | S |
W_GUESTROOM315_318_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 36.90 | 180.00 | 90.00 | S |
W_ELEVATORCOREFLR3_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 5.02 | 180.00 | 90.00 | S |
W_GUESTROOM319_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 180.00 | 90.00 | S |
W_GUESTROOM320_323_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 36.90 | 180.00 | 90.00 | S |
W_GUESTROOM324_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 180.00 | 90.00 | S |
W_FRONTSTORAGEFLR3_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 4.18 | 4.18 | 180.00 | 90.00 | S |
W_FRONTSTAIRSFLR3_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 6.69 | 180.00 | 90.00 | S |
W_FRONTSTAIRSFLR3_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 22.58 | 90.00 | 90.00 | E |
W_REARSTAIRSFLR4_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 22.58 | 270.00 | 90.00 | W |
W_REARSTAIRSFLR4_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 6.69 | 180.00 | 90.00 | S |
R_REARSTAIRSFLR4_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 20.07 | 20.07 | 0.00 | 0.00 | |
W_CORRIDORFLR4_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 3.71 | 270.00 | 90.00 | W |
W_CORRIDORFLR4_9_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.36 | 8.36 | 180.00 | 90.00 | S |
W_CORRIDORFLR4_15_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 3.71 | 90.00 | 90.00 | E |
R_CORRIDORFLR4_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 125.42 | 125.42 | 0.00 | 0.00 | |
W_REARSTORAGEFLR4_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 22.58 | 270.00 | 90.00 | W |
W_REARSTORAGEFLR4_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 6.69 | 0.00 | 90.00 | N |
R_REARSTORAGEFLR4_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 20.07 | 20.07 | 0.00 | 0.00 | |
W_GUESTROOM401_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 22.58 | 90.00 | 90.00 | E |
W_GUESTROOM401_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 0.00 | 90.00 | N |
R_GUESTROOM401_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 32.61 | 32.61 | 0.00 | 0.00 | |
W_GUESTROOM402_405_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 36.90 | 0.00 | 90.00 | N |
R_GUESTROOM402_405_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 130.45 | 130.45 | 0.00 | 0.00 | |
W_GUESTROOM406_408_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.12 | 28.42 | 0.00 | 90.00 | N |
R_GUESTROOM406_408_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 105.36 | 105.36 | 0.00 | 0.00 | |
W_GUESTROOM409_412_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 36.90 | 0.00 | 90.00 | N |
R_GUESTROOM409_412_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 130.45 | 130.45 | 0.00 | 0.00 | |
W_GUESTROOM413_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 0.00 | 90.00 | N |
R_GUESTROOM413_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 32.61 | 32.61 | 0.00 | 0.00 | |
W_GUESTROOM414_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 180.00 | 90.00 | S |
R_GUESTROOM414_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 32.61 | 32.61 | 0.00 | 0.00 | |
W_GUESTROOM415_418_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 36.90 | 180.00 | 90.00 | S |
R_GUESTROOM415_418_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 130.44 | 130.44 | 0.00 | 0.00 | |
W_ELEVATORCOREFLR4_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 5.02 | 180.00 | 90.00 | S |
R_ELEVATORCOREFLR4_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 15.05 | 15.05 | 0.00 | 0.00 | |
W_GUESTROOM419_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 180.00 | 90.00 | S |
R_GUESTROOM419_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 32.61 | 32.61 | 0.00 | 0.00 | |
W_GUESTROOM420_423_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 36.90 | 180.00 | 90.00 | S |
R_GUESTROOM420_423_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 130.44 | 130.44 | 0.00 | 0.00 | |
W_GUESTROOM424_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 9.22 | 180.00 | 90.00 | S |
R_GUESTROOM424_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 32.61 | 32.61 | 0.00 | 0.00 | |
W_FRONTSTORAGEFLR4_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 4.18 | 4.18 | 180.00 | 90.00 | S |
R_FRONTSTORAGEFLR4_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 12.54 | 12.54 | 0.00 | 0.00 | |
W_FRONTSTAIRSFLR4_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 6.69 | 180.00 | 90.00 | S |
W_FRONTSTAIRSFLR4_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 22.58 | 90.00 | 90.00 | E |
R_FRONTSTAIRSFLR4_1_0_0 | RES_ROOF | 0.55 | 0.221 | 0.228 | 20.07 | 20.07 | 0.00 | 0.00 | |
S_REARSTAIRSFLR1_0_0_0 | S_REARSTAIRSFLR1_0_0_0_FFACTOR | 1.00 | 0.750 | 20.07 | 20.07 | 180.00 | 180.00 | ||
S_CORRIDORFLR1_0_0_0 | S_CORRIDORFLR1_0_0_0_FFACTOR | 1.00 | 0.083 | 150.51 | 150.51 | 180.00 | 180.00 | ||
S_REARSTORAGEFLR1_0_0_0 | S_REARSTORAGEFLR1_0_0_0_FFACTOR | 1.00 | 0.750 | 20.07 | 20.07 | 180.00 | 180.00 | ||
S_FRONTLOUNGEFLR1_0_0_0 | S_FRONTLOUNGEFLR1_0_0_0_FFACTOR | 1.00 | 0.225 | 163.06 | 163.06 | 180.00 | 180.00 | ||
S_RESTROOMFLR1_0_0_0 | S_RESTROOMFLR1_0_0_0_FFACTOR | 1.00 | 0.157 | 32.61 | 32.61 | 180.00 | 180.00 | ||
S_MEETINGROOMFLR1_0_0_0 | S_MEETINGROOMFLR1_0_0_0_FFACTOR | 1.00 | 0.157 | 80.27 | 80.27 | 180.00 | 180.00 | ||
S_MECHANICALROOMFLR1_0_0_0 | S_MECHANICALROOMFLR1_0_0_0_FFACTOR | 1.00 | 0.157 | 32.61 | 32.61 | 180.00 | 180.00 | ||
S_GUESTROOM101_0_0_0 | S_GUESTROOM101_0_0_0_FFACTOR | 1.00 | 0.157 | 32.61 | 32.61 | 180.00 | 180.00 | ||
S_GUESTROOM102_0_0_0 | S_GUESTROOM102_0_0_0_FFACTOR | 1.00 | 0.157 | 32.61 | 32.61 | 180.00 | 180.00 | ||
S_GUESTROOM103_0_0_0 | S_GUESTROOM103_0_0_0_FFACTOR | 1.00 | 0.157 | 32.61 | 32.61 | 180.00 | 180.00 | ||
S_GUESTROOM104_0_0_0 | S_GUESTROOM104_0_0_0_FFACTOR | 1.00 | 0.157 | 32.61 | 32.61 | 180.00 | 180.00 | ||
S_GUESTROOM105_0_0_0 | S_GUESTROOM105_0_0_0_FFACTOR | 1.00 | 0.157 | 32.61 | 32.61 | 180.00 | 180.00 | ||
S_EMPLOYEELOUNGEFLR1_0_0_0 | S_EMPLOYEELOUNGEFLR1_0_0_0_FFACTOR | 1.00 | 0.157 | 32.61 | 32.61 | 180.00 | 180.00 | ||
S_LAUNDRYROOMFLR1_0_0_0 | S_LAUNDRYROOMFLR1_0_0_0_FFACTOR | 1.00 | 0.157 | 97.83 | 97.83 | 180.00 | 180.00 | ||
S_ELEVATORCOREFLR1_0_0_0 | S_ELEVATORCOREFLR1_0_0_0_FFACTOR | 1.00 | 0.157 | 15.05 | 15.05 | 180.00 | 180.00 | ||
S_EXERCISECENTERFLR1_0_0_0 | S_EXERCISECENTERFLR1_0_0_0_FFACTOR | 1.00 | 0.157 | 32.61 | 32.61 | 180.00 | 180.00 | ||
S_FRONTOFFICEFLR1_0_0_0 | S_FRONTOFFICEFLR1_0_0_0_FFACTOR | 1.00 | 0.157 | 130.44 | 130.44 | 180.00 | 180.00 | ||
S_FRONTSTAIRSFLR1_0_0_0 | S_FRONTSTAIRSFLR1_0_0_0_FFACTOR | 1.00 | 0.750 | 20.07 | 20.07 | 180.00 | 180.00 | ||
S_FRONTSTORAGEFLR1_0_0_0 | S_FRONTSTORAGEFLR1_0_0_0_FFACTOR | 1.00 | 0.157 | 12.54 | 12.54 | 180.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
W_CORRIDORFLR1_2_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 2.69 | 0.00 | 0.00 | 2.69 | 2.69 | 2.615 | 0.252 | 0.276 | No | W_CORRIDORFLR1_2_0_0 | 270.00 | 90.00 | W | ||
D_CORRIDORFLR1_16_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 4.44 | 0.00 | 0.00 | 4.44 | 4.44 | 2.615 | 0.252 | 0.276 | No | W_CORRIDORFLR1_16_0_0 | 90.00 | 90.00 | E | ||
W_CORRIDORFLR1_20_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 2.69 | 0.00 | 0.00 | 2.69 | 2.69 | 2.615 | 0.252 | 0.276 | No | W_CORRIDORFLR1_20_0_0 | 0.00 | 90.00 | N | ||
W_FRONTLOUNGEFLR1_5_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.615 | 0.252 | 0.276 | No | W_FRONTLOUNGEFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_FRONTLOUNGEFLR1_5_0_0_0_1 | NONRESWINDOW_U_0.46_SHGC_0.25 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.615 | 0.252 | 0.276 | No | W_FRONTLOUNGEFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_FRONTLOUNGEFLR1_5_0_0_0_2 | NONRESWINDOW_U_0.46_SHGC_0.25 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.615 | 0.252 | 0.276 | No | W_FRONTLOUNGEFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_FRONTLOUNGEFLR1_5_0_0_0_3 | NONRESWINDOW_U_0.46_SHGC_0.25 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.615 | 0.252 | 0.276 | No | W_FRONTLOUNGEFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_FRONTLOUNGEFLR1_5_0_0_0_4 | NONRESWINDOW_U_0.46_SHGC_0.25 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.615 | 0.252 | 0.276 | No | W_FRONTLOUNGEFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_MEETINGROOMFLR1_5_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_MEETINGROOMFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_MEETINGROOMFLR1_5_0_0_0_1 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_MEETINGROOMFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_MEETINGROOMFLR1_5_0_0_0_2 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_MEETINGROOMFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM101_5_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM101_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM102_5_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM102_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM103_5_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM103_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM104_3_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM104_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM105_3_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM105_3_0_0 | 180.00 | 90.00 | S | ||
W_EMPLOYEELOUNGEFLR1_3_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_EMPLOYEELOUNGEFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_LAUNDRYROOMFLR1_3_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_LAUNDRYROOMFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_LAUNDRYROOMFLR1_3_0_0_0_1 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_LAUNDRYROOMFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_LAUNDRYROOMFLR1_3_0_0_0_2 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_LAUNDRYROOMFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_EXERCISECENTERFLR1_3_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_EXERCISECENTERFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_FRONTOFFICEFLR1_3_0_0_0_0 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_FRONTOFFICEFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_FRONTOFFICEFLR1_3_0_0_0_1 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_FRONTOFFICEFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_FRONTOFFICEFLR1_3_0_0_0_2 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_FRONTOFFICEFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_FRONTOFFICEFLR1_3_0_0_0_3 | NONRESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_FRONTOFFICEFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_CORRIDORFLR2_2_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.615 | 0.252 | 0.276 | No | W_CORRIDORFLR2_2_0_0 | 270.00 | 90.00 | W | ||
W_CORRIDORFLR2_15_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.615 | 0.252 | 0.276 | No | W_CORRIDORFLR2_15_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM201_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM201_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM202_205_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM202_205_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM202_205_5_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM202_205_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM202_205_5_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM202_205_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM202_205_5_0_0_0_3 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM202_205_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM206_208_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM206_208_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM206_208_5_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 3.41 | 0.00 | 0.00 | 3.41 | 3.41 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM206_208_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM206_208_5_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM206_208_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM209_212_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM209_212_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM209_212_5_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM209_212_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM209_212_5_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM209_212_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM209_212_5_0_0_0_3 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM209_212_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM213_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM213_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM214_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM214_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM215_218_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM215_218_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM215_218_3_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM215_218_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM215_218_3_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM215_218_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM215_218_3_0_0_0_3 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM215_218_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM219_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM219_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM220_223_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM220_223_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM220_223_3_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM220_223_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM220_223_3_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM220_223_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM220_223_3_0_0_0_3 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM220_223_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM224_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM224_3_0_0 | 180.00 | 90.00 | S | ||
W_CORRIDORFLR3_2_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.615 | 0.252 | 0.276 | No | W_CORRIDORFLR3_2_0_0 | 270.00 | 90.00 | W | ||
W_CORRIDORFLR3_15_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.615 | 0.252 | 0.276 | No | W_CORRIDORFLR3_15_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM301_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM301_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM302_305_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM302_305_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM302_305_5_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM302_305_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM302_305_5_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM302_305_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM302_305_5_0_0_0_3 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM302_305_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM306_308_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM306_308_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM306_308_5_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 3.41 | 0.00 | 0.00 | 3.41 | 3.41 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM306_308_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM306_308_5_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM306_308_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM309_312_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM309_312_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM309_312_5_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM309_312_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM309_312_5_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM309_312_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM309_312_5_0_0_0_3 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM309_312_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM313_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM313_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM314_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM314_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM315_318_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM315_318_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM315_318_3_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM315_318_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM315_318_3_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM315_318_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM315_318_3_0_0_0_3 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM315_318_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM319_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM319_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM320_323_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM320_323_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM320_323_3_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM320_323_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM320_323_3_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM320_323_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM320_323_3_0_0_0_3 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM320_323_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM324_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM324_3_0_0 | 180.00 | 90.00 | S | ||
W_CORRIDORFLR4_2_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.615 | 0.252 | 0.276 | No | W_CORRIDORFLR4_2_0_0 | 270.00 | 90.00 | W | ||
W_CORRIDORFLR4_15_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.615 | 0.252 | 0.276 | No | W_CORRIDORFLR4_15_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM401_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM401_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM402_405_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM402_405_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM402_405_5_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM402_405_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM402_405_5_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM402_405_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM402_405_5_0_0_0_3 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM402_405_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM406_408_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM406_408_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM406_408_5_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM406_408_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM406_408_5_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 3.41 | 0.00 | 0.00 | 3.41 | 3.41 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM406_408_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM409_412_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM409_412_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM409_412_5_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM409_412_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM409_412_5_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM409_412_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM409_412_5_0_0_0_3 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM409_412_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM413_5_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM413_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM414_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM414_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM415_418_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM415_418_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM415_418_3_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM415_418_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM415_418_3_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM415_418_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM415_418_3_0_0_0_3 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM415_418_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM419_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM419_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM420_423_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM420_423_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM420_423_3_0_0_0_1 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM420_423_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM420_423_3_0_0_0_2 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM420_423_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM420_423_3_0_0_0_3 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM420_423_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM424_3_0_0_0_0 | RESWINDOW_U_0.46_SHGC_0.25 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.615 | 0.252 | 0.276 | No | W_GUESTROOM424_3_0_0 | 180.00 | 90.00 | S | ||
Total or Average | 184.20 | 2.615 | 0.252 | 0.276 | ||||||||||||
North Total or Average | 96.82 | 2.615 | 0.252 | 0.276 | ||||||||||||
Non-North Total or Average | 87.38 | 2.615 | 0.252 | 0.276 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
W_REARSTAIRSFLR1_3_0_0_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | W_REARSTAIRSFLR1_3_0_0 |
W_CORRIDORFLR1_10_0_0_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | W_CORRIDORFLR1_10_0_0 |
W_FRONTSTAIRSFLR1_3_0_0_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | W_FRONTSTAIRSFLR1_3_0_0 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 20:15:15
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
W_CORRIDORFLR1_2_0_0_0_0 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
D_CORRIDORFLR1_16_0_0_0_0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 | 0.13 | 0.00 |
W_CORRIDORFLR1_20_0_0_0_0 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
W_FRONTLOUNGEFLR1_5_0_0_0_0 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
W_FRONTLOUNGEFLR1_5_0_0_0_1 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
W_FRONTLOUNGEFLR1_5_0_0_0_2 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
W_FRONTLOUNGEFLR1_5_0_0_0_3 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
W_FRONTLOUNGEFLR1_5_0_0_0_4 | 0.00 |